SSANGYONG NEW ACTYON SPORTS 2012 Service Manual
Manufacturer: SSANGYONG, Model Year: 2012, Model line: NEW ACTYON SPORTS, Model: SSANGYONG NEW ACTYON SPORTS 2012Pages: 828, PDF Size: 91.28 MB
Page 761 of 828

01-4
Condenser assembly
Compressor assembly - A/C
Hose assembly - Discharge
O-ring
O-ring
O-ring
O-ring
Hose assembly - Heater inlet
Hose assembly - Heater outlet
Pipe assembly - Joint
O-ring
O-ring
Pipe assembly - Liquid No.1
Pipe assembly - Liquid No.2 1.
2.
3.
4.
5.
7.
8.
9.
10.
11.
12.
13.
14.
15.O-ring
Pipe assembly - Liquid No.3
Hose assembly - Liquid
Receiver drier and bracket assembly
Nut
Nut
Bracket assembly - A/C compressor
Bolt
Bracket assembly - A/C compressor sub
Bolt
Hose - Drain
Sensor assembly - Receiver drier
Cap - Charge valve 16.
17.
18.
19.
20.
21.
22.
23.
25.
26.
27.
30.
50.
Page 762 of 828

01-56810-01
Duct assembly - Console front
Screw
Duct assembly - Console rear
Duct assembly - Console foot
Duct assembly - Foot 1.
4.
8.
9.
10.
Page 763 of 828

01-6
The FATC has a self-diagnosis function that can diagnose the system by itself. Before checking a
component, be sure to check the fault code by using the self-diagnosis function. The self-
diagnosis consists of 6 steps. The temperature control dial (step 2 to 5) and fan speed dial (step
6) are used to enter each step of the self-diagnosis. The 6 steps of the self-diagnosis are:
▶ Step 1
▶ Step 2
▶ Step 3
▶ Step 4- The VFD and all LED segments are checked for proper illumination.
- The sensors and air mix door are checked for proper operation.
- The position and condition of the air source door and mode door are checked.
The actuator door position, fan speed and compressor operation are checked. Pressing
the defroster switch after entering step 4 changes the diagnosis mode as follows: 41 -> 42
-> 43 -> 44 -> 45 -> 46 -> 41. -
3. TROUBLESHOOTING
1) Overview
Page 764 of 828

01-76810-01
▶ Step 5
Ambient
temperature
display
51
Interior
temperature
displayIntake air temperature
display
Ambient
temperature
sensorInterior
temperature
sensorIntake air
temperature sensor
▶ Step 6
To enter the step 6 from 5, turn the fan speed dial lightly toward the right not using the
temperature control dial. In this step, you can decrease or increase by up to 3 degrees
from the temperature set on the A/C controller. -You can check that the temperature value from each temperature sensor is displayed
properly in this step. Pressing the defroster switch changes the temperature value that
appears on the display in the order as follows: -
2) Self-diagnosis step
(1) Step 1
Turn the ignition ON and press the OFF switch for 5 sec. or more within 10 sec.
Then the first step of the self-diagnosis is started as shown in the below figure.
2. Display for checking VFD and all LED segments
1. Press OFF switch for 5 sec. or more
Page 765 of 828

01-8
(2) Step 2
The sensors and air mix door are checked for proper operation in this step. When the step 2 is
started, the number "2", which indicates that the system is in the step 2, apprears on the display
and the check for sensors is performed. Once the check is done (for 10 to 20 sec.), the one digit
number between 0 and 8 is added behind "2". "20" means there is no fault code. For the meaning
of the rest of the numbers, refer to the description below.
1. Turn temperature dial lightly toward right to enter step 2
10 to 20
sec.
System starts sensor
check after "2" is
displayed 2.
Fault code for sensor
appears and blinks 3.
Fault code no. 1
(ambient temperature
sensor) blinks twiceFault code no. 5 (sun
sensor) blinks twice
(fault codes appears
sequentially)
If "-" is displayed before "2", it means
that the sensor for that flashing fault
code has a short circuit.
Ambient temperature
sensor short
circuited
Refer to the following table for the meaning of the fault code.
Page 766 of 828

01-96810-01
(3) Step 3
In this step, you can check the position and condition of the air source door and mode door. To
start step 3, turn the temperature control dial lightly toward the right and confirm that the number 3
appears on the display. It takes several tens of seconds to finish the check. If there is no fault
code, "30" is displayed. And if there is a malfunction, the corresponding fault code is added as
described in the step 2.
Turn temperature dial lightly toward
right to enter step 3 1.
System starts
sensor check after
"3" is displayed 2. Fault code for
sensor appears
and blinks (30 is
displayed when
there is no fault) 3.
Refer to the following table for the meaning of the fault code.
Page 767 of 828

01-10
In this step, the door position of each actuator, fan speed and operation of the compressor are
checked. To enter this step, turn the temperature dial to the right in the step 3. The number, "41",
appears on the display as soon as the step 4 is started. Press the defroster switch to change the
diagnosis mode.
(4) Step 4
Press
Press
Press
PressPress
Press
Turn temperature dial lightly
toward right to enter step 4 1.
Below table describes the detailed diagnosis items performed for each number. Check the
corresponding component for proper operation according to the table. The voltage values listed
in the table are the output voltage to operate the blower motor. The higher the voltage, the faster
the fan speed is.
Page 768 of 828

01-116810-01
(5) Step 5
In this step, the system checks the temperature sensors used to control the A/C. To enter this
step, turn the temperature dial to the right in the step 4. The ambient temperature appears on the
display first and the interior temperature appears next and the intake air temperature last. The
display changes the temperature value each time the defroster switch is pressed.
1. Turn temperature dial lightly toward right to enter step 5
Press Press Press
Ambient
temperature
displayInterior
temperature
displayIntake air
temperature
display
(6) Step 6
You can increase or decrease by up to 3 degrees from the set temperature. When entering the
step 6 from 5, turn the fan speed dial.
Step 6 starts Decrease by up
to 3 degreesIncrease by up
to 3 degreesTurn fan
speed dial
to enter
step 6 1.
Turn
temperature
control dial to
adjust
temperature 2.
Page 769 of 828

01-12
(7) How to end self-diagnosis
Turn the AUTO switch ON or turn OFF the ignition key.
(8) When A/C system is faulty (Initial auto-diagnosis)
The fault code for the faulty sensor is not displayed. Therefore you should start the self-diagnosis
to check the system.
Page 770 of 828

01-136810-01
3) Trouble Diagnosis
(1) Duct Temperature Sensor
If the fault code for the duct temperature sensor (DTC 3) appears on the display, check the sensor
as follows:
Remove the duct temperature sensor and measure the resistance between the terminals of the
<008a009600950095008c008a009b009600990047004f009a0097008c008a0090008d0090008a0088009b0090009600950061004700880097009700990096009f0055004700590055005900470092007e00470088009b00470059005c0b4500500055004700
70008d0047009b008f008c00470099008c009a0090009a009b>ance value is extremely high or
low, replace the duct temperature sensor.
If the result is not as specified, replace the duct temperature sensor. If the result is as
specified, proceed to the next step.
Turn the ignition switch to ON position and measure the voltage between the connector of the
FATC controller and the duct temperature sensor (specification: approx. 2 V at 25℃).
If the voltage cannot be measured, check the wiring for open circuit. If the result is as
specified, replace the FATC controller. A.
B.
C.
D.
(2) Power Transistor
If the fault code for the power transistor (DTC 6) is displayed, check as follows:
Turn the ignition switch to ON position.
Measure the voltage between the terminals of the blower motor while changing the fan speed
from the lowest level to the highest level.
The specified voltage value in each stage: A.
B.
C.
If the voltage is out of specified value, check the wiring for open circuit. If the wiring is intact,
replace the power transistor. D.
(3) Thermo AMP Sensor (Intake Air Sensor)
If the A/C is not turned on, check as follows:
Remove the thermo AMP and measure the voltage between the terminals no. 1 and 2 of the
connector.
Check if the voltage is approx. 12 V when the output is ON and 0 V when the output is OFF.
If the voltage value is not as specified, replace the thermo AMP. If the value is as specified,
proceed to the next step.
Turn the ignition switch to ON position and turn on the A/C by pressing the A/C button. And
measure the voltage between the terminals A12 and A11 of the FATC controller connector
(specification: approx. 12 V).
If the voltage cannot be measured, check the wiring for open circuit. If the result is not as
specified, replace the thermo AMP. A.
B.
C.
D.
E.