Page 90 of 801
YH4
GRAND
VITARA
SYSTEM CIRCUIT
A. To heater fuse
B. To rear defogger fuse
C. To ignition / meter fuse
D. To A / C fuse
E. Only LH vehicle1. Blower motor relay
2. Blower motor
3. Blower motor switch
4. A / C switch
5. Deflloster position switch
6. Deflloster / foot position switch7. Dual pressure (refrigerant
pressure) switch
8. A / C thermistor (evaporator
temperature sensor)
9. Compressor relay
10. Compressor11. Condenser fan motor relay
12. Condenser fan motor
13. A / C controller
14. ECM
15. Compressor thermal switch
(only IWATA production vehicle)
TERMINAL ARRANGEMENT OF A / C CONTROLLER
TERMINAL ARRANGEMENT OF ECM FOR G16, J20 ENGINE
TERMINAL ARRANGEMENT OF ECM FOR H25 ENGINE
H25 engine
E61-27
G16, J20
engines
E61-8
H25 engine
E61-28
G16, J20
engines
E61-17
1919
19H25 engine
E61-5
G16, J20
engines
E61-22
AIR CONDITIONING (OPTIONAL) 1B-19
Page 92 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150 )Evaporator thermistor temperature at
approx. 15C (59F) with engine
running
AC2-2W/B
Evaporator
thermistor
temperature
(evaporator temp.
sensor) input
Ground to engine
(Fig. B)
2.62 volts
(6.311 )
Evaporator thermistor temperature at
approx. 1C (34F) with engine
running
* If the temperature is less than
approx. 1C, in this case
compressor and condenser fan
should be stop (come back at more
than approx. 2.5C (less than
5840 , 2.5 V))
H25
engine
E61-27 /
G16 J20Gr/W
Signal output to
A / C controller
(A / C ON
Ground to engine
(Fig C)
10 ± 14 volts
Required A / C ON (terminal AC-A13)
at engine running with normal
condition (refer to ªINSPECTION OF
ECM AND ITS CIRCUITº in Section
6E)
G16, J20
engines
E61-8
(
permission
signal)(Fig. C)
0 ± 1 volt
Except the above-mentioned with
engine running
In this case compressor should be
stop
H25
engine
E61-28 /
Y/B
Signal input from
A / C controller
Ground to engine
0 ± 1.5 voltsRequire A / C ON
G16, J20
engines
E61-17Y/B(A / C ON request
signal)
g
(Fig. C)
10 ± 14 voltsTurn off the A / C
H25
engine
E61-5 /
G16, J20
engines
E61-22
Y/L
A / C condenser
cooling fan relay
outputGround to engine
(Fig. C)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch (see
NOTE) ON with engine running at
evaporator thermistor temperature
input more than approx. 2.5C (less
than 2.5 V (5840 )), refrigerant
pressure switch ON and signal
input from ECM ON
Engine coolant temperature sensor
more than 113C (236F) with
engine running
10 ± 14 voltsExcept the above-mentioned with
engine running
NOTE:
Defroster position switch circuit is equipped with LH vehicle only.
Page 476 of 801
YH4
GRAND
VITARA
7B1-74 AUTOMATIC TRANSMISSION (4 A / T)
1. Boot No.2
2. Boot cover
1. Boot clamp
2. Boot No.1
3. Gear shift control lever
1. Boot No.2
2. Transfer shift control
lever
3. Transfer shift lever case4. Transfer shift control
case cover
5. Boot No.1
1. A / T throttle cable
2. Adjusting nut
3. Lock nut
G16 / J20 H25
DISMOUNTING OF TRANSMISSION (WITH
TRANSFER IF EQUIPPED)
IN CABIN
1) Remove console box.
NOTE:
To remove clip, push in its center pin first.
2) Remove boot cover and boot No.2. (if equipped)
3) Remove boot clamp and then remove boot No.1 from transfer
gear shift lever case. (if equipped)
4) With transfer shift control case cover pushed down with fingers,
turn it to counterclockwise and take out shift control lever. (if
equipped)
IN ENGINE ROOM
1) Remove battery, dipstick and oil filler tube.
2) Disconnect A/T throttle cable from throttle cam and bracket.
3) Remove starter motor. But don't disconnect its wiring harness.
4) Remove transmission to engine bolt and nut.
Page 510 of 801
YH4
GRAND
VITARA
7E-8 DIFFERENTIAL (FRONT)
1. ECM (PCM); viewed from harness side
Voltage Check [H25 engine model]
TER-
MINALCIRCUITWIRE
COLORNORMAL
VOLTAGECONDITION
C51 110 ± 14 VTransfer shift lever: 2H or NC51-1
-74WD Indicator lampOr / B0 ± 1 V4 seconds after transfer shift lever shifted
to 4H or 4L
C51 1Air pump assembly0 ± 1 VTransfer shift lever: 2H or NC51-1
-15(Pump motor and release
valve)R10 ± 14 V1 seconds after transfer shift lever shifted
to 4H or 4L
C51-14WD switchB/Or10 ± 14 VTransfer shift lever: 2H or N
-114WD switchB/Or0 ± 1 VTransfer shift lever: 4H or 4L
C51-3
-26GroundB/Bl0 ± 1 V±
C51-1Airpumpassembly0 ± 1 VTransfer shift lever: 2H or NC51-1
-18
Air um assembly
(pressure switch)P10 ± 14 V4 seconds after transfer shift lever shifted
to 4H or 4L