engine control SUZUKI GRAND VITARA 2003 2.G Service User Guide
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2003, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 2003 2.GPages: 801, PDF Size: 12.15 MB
Page 90 of 801

YH4
GRAND
VITARA
SYSTEM CIRCUIT
A. To heater fuse
B. To rear defogger fuse
C. To ignition / meter fuse
D. To A / C fuse
E. Only LH vehicle1. Blower motor relay
2. Blower motor
3. Blower motor switch
4. A / C switch
5. Deflloster position switch
6. Deflloster / foot position switch7. Dual pressure (refrigerant
pressure) switch
8. A / C thermistor (evaporator
temperature sensor)
9. Compressor relay
10. Compressor11. Condenser fan motor relay
12. Condenser fan motor
13. A / C controller
14. ECM
15. Compressor thermal switch
(only IWATA production vehicle)
TERMINAL ARRANGEMENT OF A / C CONTROLLER
TERMINAL ARRANGEMENT OF ECM FOR G16, J20 ENGINE
TERMINAL ARRANGEMENT OF ECM FOR H25 ENGINE
H25 engine
E61-27
G16, J20
engines
E61-8
H25 engine
E61-28
G16, J20
engines
E61-17
1919
19H25 engine
E61-5
G16, J20
engines
E61-22
AIR CONDITIONING (OPTIONAL) 1B-19
Page 91 of 801

YH4
GRAND
VITARA
1B-20 AIR CONDITIONING (OPTIONAL)
A / C CONTROLLER VOLTAGE VALUES TABLE
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC1-1B/WController main
power supplyGround to
engine (Fig. B)10 ± 14 voltsIgnition switch ON with engine
stopped
AC1-2B/YController main
groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
AC1 4Or
Refrigerant
p
ressure switchGround to
0 ± 1 volt
Refrigerant pressure within 225 kPa
(2.3 kg / cm
2, 32.7 psi) to 2548 kPa
(26 kg / cm
2, 370 psi) with engine
running
AC1-4Orpressure switch
inputengine (Fig. B)
10 ± 14 volts
Refrigerant pressure below
196 kPa (2.0 kg / cm
2, 28 psi) or
above 3140 kPa (32 kg / cm
2, 455 psi)
with engine running
AC1 7G/B
A / C switch input
and / or defroster
Ground to
8 ± 14 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running
AC1-7G/Bposition switch
input (see NOTE)engine (Fig. B)
0 ± 1.5 volts
Blower fan motor switch or A / C or
defroster position switch (see NOTE)
OFF with engine running
AC1 9Gr/W
Signal input from
ECM (A / C ON
Ground to10 ± 14 voltsApprove of A / C ON
AC1-9Gr/W(
permission
signal)engine (Fig. B)0 ± 1 voltA / C ON forbid
AC1-13Y/B
Signal output to
ECM (A / C ON
request signal)Ground to engine
(Fig. B)0 ± 1.5 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )) and refrigerant pressure
switch is ON
10 ± 14 voltsExcept the above-mentioned with
engine running
AC1-16P
Compressor
magnet clutch
relay outputGround to engine
(Fig. B)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch ON with
engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )), refrigerant pressure
switch ON and signal input from ECM
ON
10 ± 14 voltsExcept the above-mentioned with
engine running
Page 92 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150 )Evaporator thermistor temperature at
approx. 15C (59F) with engine
running
AC2-2W/B
Evaporator
thermistor
temperature
(evaporator temp.
sensor) input
Ground to engine
(Fig. B)
2.62 volts
(6.311 )
Evaporator thermistor temperature at
approx. 1C (34F) with engine
running
* If the temperature is less than
approx. 1C, in this case
compressor and condenser fan
should be stop (come back at more
than approx. 2.5C (less than
5840 , 2.5 V))
H25
engine
E61-27 /
G16 J20Gr/W
Signal output to
A / C controller
(A / C ON
Ground to engine
(Fig C)
10 ± 14 volts
Required A / C ON (terminal AC-A13)
at engine running with normal
condition (refer to ªINSPECTION OF
ECM AND ITS CIRCUITº in Section
6E)
G16, J20
engines
E61-8
(
permission
signal)(Fig. C)
0 ± 1 volt
Except the above-mentioned with
engine running
In this case compressor should be
stop
H25
engine
E61-28 /
Y/B
Signal input from
A / C controller
Ground to engine
0 ± 1.5 voltsRequire A / C ON
G16, J20
engines
E61-17Y/B(A / C ON request
signal)
g
(Fig. C)
10 ± 14 voltsTurn off the A / C
H25
engine
E61-5 /
G16, J20
engines
E61-22
Y/L
A / C condenser
cooling fan relay
outputGround to engine
(Fig. C)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch (see
NOTE) ON with engine running at
evaporator thermistor temperature
input more than approx. 2.5C (less
than 2.5 V (5840 )), refrigerant
pressure switch ON and signal
input from ECM ON
Engine coolant temperature sensor
more than 113C (236F) with
engine running
10 ± 14 voltsExcept the above-mentioned with
engine running
NOTE:
Defroster position switch circuit is equipped with LH vehicle only.
Page 146 of 801

YH4
GRAND
VITARA
1. Power steering gear box
2. Power steering pump
3. P / S fluid reservoir
1. Power steering pump
2. Valve section
3. P / S fluid reservoir
4. Rack
5. Pinion
6. Cylinder
3B1-2 POWER STEERING (P / S) SYSTEM
GENERAL DESCRIPTION
POWER STEERING SYSTEM
The power steering (P / S) system in this vehicle reduces the driver's effort needed in turning the steering wheel
by utilizing the hydraulic pressure generated by the power steering (P / S) pump which is driven by the engine.
It is an integral type with the rack and pinion gears and the control valve unit, hydraulic pressure cylinder unit all
built in the steering gear box.
Page 148 of 801

YH4
GRAND
VITARA
1. Suction connector
2. O-ring
3. Pressure switch
4. Flow control valve
(Relief valve)
5. Spring
6. Plug
7. Pump cover
8. Cam ring
9. Vane
10. Rotor
11. Snap ring
12. Side plate
13. Pulley (pump shaft)
14. Oil seal
15. Pump body
16. Flow control valve Assembly
3B1-4 POWER STEERING (P / S) SYSTEM
POWER STEERING (P / S) PUMP
The power steering pump is a vane type and is driven by the V-ribbed belt from the crankshaft.
ModelVane type
Hydraulic
pressure
controlRelieved
pressure
6500 kPa (65 kg / cm2, 924 psi)
G16 Type engine . . . . . . . . . . . . . . . . . . . . . .
7000 kPa (70 kg / cm
2, 995 psi)
J20 Type engine . . . . . . . . . . . . . . . . . . . . . . .
7350 kPa (73.5 kg / cm
2, 1045 psi)
H25 Type engine . . . . . . . . . . . . . . . . . . . . . .
ControlFlow control valve
deviceRelief valve
Power steering
pressure switch
Switch turns on (closes) when the
pressure is higher than 2500 ± 3500 kPa
(25 ± 35 kg / cm
2, 356 ± 498 psi).
ECM uses this signal for idle speed control.
Capacity0.70 ± 0.75
(1.48 / 1.23 ± 1.58 / 1.32 US / Imp. pt)
Specified fluidDEXRONII, DEXRONIII A / T fluid
or equivalent
FLOW CONTROL VALVE
As the discharge rate of the P/S pump increases in proportion to the
pump revolution speed, a flow control valve is added to control it so
that the optimum amount of fluid for steering operation is supplied
according to the engine speed (driving condition).
Described below is its operation at different engine speed.
Page 361 of 801

YH4
GRAND
VITARA
5E1-20 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
TABLE ± E EBD WARNING LAMP (BRAKE WARNING LAMP) CHECK-LAMP
COMES ªONº STEADY
CIRCUIT DESCRIPTION
EBD warning lamp (brake warning lamp) is controlled by parking brake switch, brake fluid level switch and ABS
control module / hydraulic unit assembly through lamp driver module in combination meter. Refer to ªTABLE-Aº for
circuit diagram.
STEP
ACTIONYESNO
11) Make sure that:
Parking brake is completely released.Go to step 2.Release parking
brake completely
Brake fluid level is upper than the minimum level.
Are the check results OK?and / or replenish
brake fluid.
2Does ªABSº warning lamp come on?Perform ªTABLE Bº
previously
outlined.Go to step 3.
31) Disconnect ABS hydraulic unit / control module
connector.
2) Check for proper connection to ABS hydraulic unit /
control module connector at terminals ªA26º.
3) If OK, apply chocks to wheels and select gear in neutral
position (P range for A / T).
4) Keep brake pedal depressed and start engine.
Release parking brake.
5) Connect terminal ªA26º of disconnected connector to
ground using service wire.
Does EBD warning lamp (brake warning lamp) turn off?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªBrº circuit open.
If wire and
connection are
OK, replace
combination
meter.
Page 384 of 801

YH4
GRAND
VITARA
7A
MANUAL TRANSMISSION (TYPE 1) 7A-1
TYPE 1
GENERAL DESCRIPTION7A- 1 . . . . . . . . . . . . . .
DIAGNOSIS7A- 2 . . . . . . . . . . . . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE7A- 3 . . . . . . . . . . . . . . . .
Gear Oil 7A- 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shift Control Levers 7A- 4. . . . . . . . . . . . . . . . . . .
Switches 7A- 6. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Engine Rear Mounting 7A- 8. . . . . . . . . . . . . . . .
Dismounting of Trans. Unit 7A- 9. . . . . . . . . . . . .
Remounting of Trans. Unit 7A-12. . . . . . . . . . . . . Extension Case (2WD MODEL) 7A-13. . . . . . . .
Extension Case Oil Seal
(2WD MODEL) 7A-13. . . . . . . . . . . . . . . . . . . . . .
UNIT REPAIR7A-14 . . . . . . . . . . . . . . . . . . . . . . . . .
TIGHTENING TORQUE
SPECIFICATIONS7A-14 . . . . . . . . . . . . . . . . . . . .
REQUIRED SERVICE MATERIALS7A-14 . . . . . .
SPECIAL TOOL7A-14 . . . . . . . . . . . . . . . . . . . . . . .
As the aluminum case is sealed with liquid type gas-
ket, it is necessary to use genuine sealant or its equiv-
alent on its mating surfaces when reassembling it.
Also, the case fastening bolts must be tightened to
specified torque by means of the torque wrench and
tightening over or below the specified torque should
be avoided.
The description under ON-VEHICLE SERVICE in this
section covers a part of the TYPE 2 manual transmis-
sion and the transfer. The transfer is next to the trans-
mission as well, but their gear boxes are independent
and each of them has its own drain and level / filler
plugs for the oil change or the level check.
For the repair procedure of the transfer unit, refer to
Section 7D.
SECTION 7A
MANUAL TRANSMISSION
(TYPE 1)
CONTENTS
GENERAL DESCRIPTION
The manual transmission consists of the input shaft,
main shaft, countershaft and reverse gear which are
installed in the aluminum case. Its gears are of for-
ward five speeds in synchro mesh and reverse one
speed in constant mesh system.
The main shaft gears are held by the needle bearings
and on them the synchronizer rings and synchronizer
sleeve & hubs are assembled.
The gear shift lever case is located at the upper be-
hind the transmission case and has a cam which pre-
vents direct gear shift from the 5th speed gear to the
reverse gear.
Page 386 of 801

YH4
GRAND
VITARA
Viscosity chart
SAE
1. Reverse idle gear shaft bolt
(DO NOT LOOSEN IT)
MANUAL TRANSMISSION (TYPE 1) 7A-3
ON-VEHICLE SERVICE
GEAR OIL
INSPECTION AND CHANGE
1) Before changing or inspecting oil, be sure to stop engine and lift
vehicle horizontally.
2) With vehicle lifted up, check oil level and leakage. If leakage ex-
ists, correct or repair it.
3) Drain old oil and fill new specified oil as shown below by speci-
fied amount (roughly up to level hole).
NOTE:
It is highly recommended to use SAE 75W-90 gear oil.
Whenever vehicle is hoisted for any other service work
than oil change, also be sure to check for oil leakage and
status of breather hoses.
If water or rust is mixed in drained oil, be sure to check
breather hose and boot of transmission and transfer.
Gear Oil Specification
Oil grade: API GL-4
Viscosity: SAE 75W-85, 75W-90 or 80W-90
Oil Capacity:
Transmission 1.5 liters (3.2 / 2.6 US / Imp. pt)
Transfer 1.7 liters (3.6 / 3.0 US / Imp. pt)
4) Torque drain plug and level / filler plug as specified below after
applying sealant to its thread.
CAUTION:
Transmission oil must not be poured through gear shift
control lever part.
Do not loosen or remove reverse idle gear shaft bolt.
ªAº: Sealant 99000-31110
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
Page 392 of 801

YH4
GRAND
VITARA
1. Transmission
2. Breather clamp
3. Breather hose
4. Wiring harness clamp
5. Intake manifold
MANUAL TRANSMISSION (TYPE 1) 7A-9
DISMOUNTING OF TRANS. UNIT
IN CABIN
Remove transmission shift control lever (refer to page 7A-4) and
transfer shift control lever knob.
IN ENGINE ROOM
1) Disconnect negative (±) cable of battery.
2) Remove breather hose from clamp at the rear end of cylinder
head.
3) Remove starting motor fixing bolts and nut and then remove
starter.
4) Remove transmission fastening bolts.
Page 395 of 801

YH4
GRAND
VITARA
1. Match mark
7A-12 MANUAL TRANSMISSION (TYPE 1)
REMOUNTING OF TRANS. UNIT
For remounting, reverse dismounting procedure.
Use specified torques as given below.
Tightening Torque
(a): 85 N
.m (8.5 kg-m, 61.5 lb-ft)
(b): 50 N
.m (5.0 kg-m, 36.5 lb-ft)
For tightening torque of transmission stiffener bolt, refer to
ªENGINE MECHANICALº section.
Set each clamp for wiring, hose and cable securely.
Set clamp for shift control lever boots securely.
After installing clutch operating cylinder, check clutch pedal free
travel. Refer to SECTION 7C1 ªCLUTCHº.
Fill gear oil to transmission and transfer as specified.
Connect battery and check function of engine, clutch and trans.
When installing propeller shaft, align the match marks.