CHRYSLER VOYAGER 2001 Service Manual

Page 781 of 4284

TEST ACTION APPLICABILITY
4 Disconnect the Passenger Door Lock Switch connector.
Measure the voltage between Door Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?All
Ye s®Go To 5
No®Repair the Door Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Door Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
752
POWER DOOR LOCKS/RKE
PASSENGER DOOR LOCK SWITCH INPUT STUCK ÐContinued

Page 782 of 4284

Symptom:
RIGHT CYLINDER LOCK SWITCH INPUT OPEN
When Monitored and Set Condition:
RIGHT CYLINDER LOCK SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch above 4.6 volts
for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE LOW
CYLINDER LOCK SWITCH GROUND OPEN
CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH OPEN
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTCs.
Operate the door locks several times from the Right Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT CYL LOCK SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the RIGHT CYL LOCK SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Right Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
753
POWER DOOR LOCKS/RKE

Page 783 of 4284

TEST ACTION APPLICABILITY
4 Disconnect the Right Cylinder Lock Switch connector.
Measure the voltage between Cylinder Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?All
Ye s®Go To 5
No®Repair the Cylinder Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
754
POWER DOOR LOCKS/RKE
RIGHT CYLINDER LOCK SWITCH INPUT OPEN ÐContinued

Page 784 of 4284

Symptom:
RIGHT CYLINDER LOCK SWITCH INPUT SHORT
When Monitored and Set Condition:
RIGHT CYLINDER LOCK SWITCH INPUT SHORT
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch below .5 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
CYLINDER LOCK SWITCH SHORTED
CYLINDER LOCK SWITCH MUX CIRCUIT SHORTED
BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE SHORTED
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the door locks several times from the Left Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT CYL LOCK SW INPUT SHORT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Right Cylinder Lock Switch connector.
With the DRBIIItin Sensors, read the RIGHT CYL SW MUX circuit
Is the voltage above 4.6 volts?All
Ye s®Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Disconnect the Right Cylinder Lock Switch connector.
Disconnect the Body Control Module C3 connector.
Measure the resistance between Cylinder Lock Switch Mux circuit and ground.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Cylinder Lock Switch Mux circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 4
755
POWER DOOR LOCKS/RKE

Page 785 of 4284

TEST ACTION APPLICABILITY
4 If there are no possible causes remaining, view repair. All
Repair
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
756
POWER DOOR LOCKS/RKE
RIGHT CYLINDER LOCK SWITCH INPUT SHORT ÐContinued

Page 786 of 4284

Symptom:
RIGHT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored and Set Condition:
RIGHT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE INCORRECT
RIGHT CYLINDER LOCK SWITCH GROUND OPEN
RIGHT CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTCs.
Operate the door lock several times from the Right Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT CYL LOCK SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the RIGHT CYL LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Right Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
757
POWER DOOR LOCKS/RKE

Page 787 of 4284

TEST ACTION APPLICABILITY
4 Disconnect the Right Cylinder Lock Switch connector.
Measure the voltage between Cylinder Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?All
Ye s®Go To 5
No®Repair the Right Cylinder Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
758
POWER DOOR LOCKS/RKE
RIGHT CYLINDER LOCK SWITCH INPUT STUCK ÐContinued

Page 788 of 4284

Symptom:
RIGHT UNLOCK OUTPUT FAILURE
When Monitored and Set Condition:
RIGHT UNLOCK OUTPUT FAILURE
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses a short condition on the right side door unlock
circuits for over 125 milliseconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RIGHT DOOR UNLOCK DRIVER SHORT TO GROUND
RIGHT FRONT DOOR UNLOCK DRIVER SHORT TO GROUND
RIGHT SLIDING DOOR UNLOCK DRIVER SHORT TO GROUND
RIGHT FRONT DOOR LOCK MOTOR - SHORT TO GROUND
RIGHT SLIDING DOOR LOCK MOTOR - SHORT TO GROUND
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle the ignition ON to OFF.
With the DRBIIIt, read DTCs.
Operate the door locks several times from the Right Door Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay RIGHT UNLOCK OUTPUT FAILURE?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Body Control Module C2 connector.
Measure the resistance between ground and the Right Front Door Unlock Driver
circuit and then the Right Sliding Door Unlock Driver circuit.
Select the appropriate reading.All
Right Front Door Unlock under 1000.0 ohm
Go To 3
Right Sliding Door Unlk under 1000.0 ohm
Go To 4
Neither circuit under 1000.0 ohms.
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
759
POWER DOOR LOCKS/RKE

Page 789 of 4284

TEST ACTION APPLICABILITY
3 Disconnect the Body Control Module C2 connector.
Disconnect the Right Front Door Lock Motor/Ajar Switch connector.
Measure the resistance between ground and the Right Front Door Unlock Driver
circuit.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Right Front Door Unlock Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Door Lock Motor.
Perform BODY VERIFICATION TEST - VER 1.
4 Disconnect the Body Control Module C2 connector.
Disconnect the Right Sliding Door Lock Motor connector.
Measure the resistance between ground and the Right Sliding Door Unlock Driver
circuit.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Right Sliding Door Unlock Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Sliding Door Lock Motor (latch assembly).
Perform BODY VERIFICATION TEST - VER 1.
760
POWER DOOR LOCKS/RKE
RIGHT UNLOCK OUTPUT FAILURE ÐContinued

Page 790 of 4284

Symptom:
RKE PROGRAM LINE OUTPUT OPEN
When Monitored and Set Condition:
RKE PROGRAM LINE OUTPUT OPEN
When Monitored: With ignition in the RUN position.
Set Condition: When the BCM senses an open or short to ground signal on the RKE
Module Program Enable circuit for longer than 0.125 msec.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - RKE MODULE PROGRAM ENABLE CIRCUIT OPEN OR SHORT TO
GROUND
RKE MODULE PROGRAM ENABLE WIRE OPEN
RKE MODULE PROGRAM ENABLE WIRE SHORT TO GROUND
RKE MODULE - PROGRAM ENABLE CIRCUIT OPEN
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTCs.
Operate the RKE transmitter while monitoring the DRBIII.
Does the DRBIIItdisplay RKE PROGRAM LINE OUTPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Body Control Module C4 connector.
Measure the voltage of the RKE Module Program Enable circuit between ground and
the BCM C4 connector.
Is the voltage between 10.2 and 11.8 volts?All
Ye s®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Turn the ignition off.
Disconnect the Remote Keyless Entry Module connector.
Disconnect the Body Control Module C4 connector.
Measure the resistance of the RKE Module Program Enable circuit between the RKE
Module connector and the BCM C4 connector.
Is the resistance below 5.0 ohms?All
Ye s®Go To 4
No®Repair the RKE Module Program Enable wire for an open
Perform BODY VERIFICATION TEST - VER 1.
761
POWER DOOR LOCKS/RKE

Page:   < prev 1-10 ... 741-750 751-760 761-770 771-780 781-790 791-800 801-810 811-820 821-830 ... 4290 next >