stop start DATSUN PICK-UP 1977 Owner's Manual

Page 506 of 537


Notes

a
The
bubbles
seen

through
the

sight

glass
are
influenced

by
the
ambient

temperature
Since
the
bubbles
are

hard
to
show

up
in

comparatively

low

temperatures
below
200C
6S0

F
it
is

possible
that

a

slightly

larger
amount
of

refrigerant
would

be
filled
if

supplied
according
to

the

sight
glass
Be

sure
to
recheck

the
amount
when
it

exceeds
200C

680F
In

higher
temperature
the

bubbles
are

easy
to

show

up

b

When
the

screen
in
the

receiver

dryer
is

clogged
the
bubbles
will

appear
even
if
the
amount
of

refrig

erant
is
normal
In
this
case
the

outlet
side

pipe
of
the
receiver

dryer
becomes

considerably
cold

PERFORMANCE
TEST

Check
for
the
amount
of

refrigerant

in
the

system
can
be

made

by
meas

uring

pressure
on

discharge
side

The

correct
amount
of

refrigerant
is

in
the

system
if

pressure
on
the

discharge
side
is
within

the

specified

range
For
details
refer
to

Perform

ance

Test
described
later

Overcharging
will
show

up
in

higher

pressure
on
discharge
side

COMPRESSOR
OIL

LEVEL

CHECK

The
oil

used
to
lubricate

compres

sor
circulates
into

system
from
the

oil

sump
while

c9mpressor
is

operating

The

efore
to

correctly
measure
com

pressor
oil
the

amount
of
oil

flowing

to

system
must
be

considered
If
a

considerable
amount
of

leakage
of

refrigerant
gas
happens
the

leakage
of

compressor
oil
is
also
considered

There

will
be

no

compressor
oil
leak

age
from
a

completely
sealed

system

When

system
operates
under

satisfying

condition
the

compressor
oil
level

check
is

unnecessary

When

checking
the
level

of
com

pressor
oil
or

when

replacing
any

component
part
of
the

system
use
the

following
service

procedure
This

fa

cilitates
to
return
oil
to

compressor

I

Operate
compressor
at

engine

idling
speed
1
000

rpm
or

below

with
controls
set

for
maximum

cooling
Air

Conditionin
j

and

high
blower

speed
for
10
to

15

minutes
in

order
to
return

compressor

oil
to

compressor

2

Stop
the

engine
and

discharge

refrigerant
of

system
and
then

remove

compressor
from

the
vehicle

3
Remove

compressor
fIller

plug

Drain

compressor
oil
from

compres

sor
oil

sump
and

measure
the

amount

4

Compressor
oil
is

satisfactory
if

the

following
amount
of
oil

remains
in

the

compressor

Residual
oil

S5
to
128

gr
3
to
4
oz

5
Check
the
cleanliness
of
the
oil
If

the
oil
contains

chips
or

other

foreign

material
clean
oil

5ump
with
new

oil

6
Discard
the

used
oil
and

fili
with

the
same
amount
of
new
oil
Add

oil
if

found
less
than
above
amount

Fig
AC
27

Filler

plug

If

compressor
is

inoperative
due
to

faulty
compressor
or

heavy
loss
of

refrigerant
remove

compressor
and

repair
as

necessary
Then

pour
oil

up

to
correct
level
and
install
on

engine

After
above

steps
have
been

complet

ed
recheck
oil
level
drain
oil
to

correct
level
if

level
is

excessively
high

PERFORMANCE
TEST

The
cooling

performance
of
the
air

conditioner

changes
considerably
with

changes
in

surrounding
conditions

Testing
must
be

performed
using
the

correct
method
This

test
is
used
to

judge
whether

system
is

operating
cor

rectly
and

can
also
be
used

as
a

guide

in

checking
for

problems

I

Park
the
vehicle
indoors
or
in
the

shade

AC
17
2

Open
all
the
windows
of
the

vehicle
fully
However

close
the

doors

3

Open
the
hood

4

Connect
manifold

gauge
to

high

and
low
side
service
valves
of
the

system
Refer
to

Handling
Manifold

Ga

uge

5

Set
fan
control
lever
to
maxi

mum

6
Set

temperature
control
lever

to

max
cool

position

7
Start
the

engine
and
hold

engine

speed
at
1
500

rpm

S
After
the
air

conditioner
has
been

operated
for
about
10
minutes

measure

system

pressures
at

high
pres

sure

discharge
side
and
low

pressure

suction
side

9
Measure
the

temperature
of
dis

charge
air
at

outlet

grille

10
Measure
the

temperature
of

capin

11
Measure
ambient

temperature

and

humidity
one
meter
3
3
ft

away

from
condenser
front
Be

careful
not

to

expose
dry
buib

and
wet
bulb

to

direct

sunlight

12
Check
for

any
abnormalities

by

comparing
the
test

results
with
stand

ard

pressure
in
Performance

Chart

Notes

a
The

pressure
will

change
in
the

followi

g
manner
with

changes
in

conditions

When

blower

speed
is

low
dis

charge

pressure
will

drop

When
the
relative

humidity
of
in

take
air
is
low

discharge
pressure

will

drop

b

The

temperature
will

change
in
the

following
manner
with

changes
in

conditions

When
the
ambient
air

temperature

is

low
the
outlet
air

temperature

will
become
low

If
the
test
reveals
that
there
is

any

abnormality
in

system
pressure
isolate

the

cause
and

repair
by
reference
to

the
Trouble

Diagnoses
and
Cor

rections

Page:   < prev 1-10 11-20 21-30