Test G FORD MUSTANG 2003 Workshop Manual
Page 3120 of 4378
GENERAL PROCEDURES
Air Conditioning (A/C) System Recovery, Evacuation and
Charging
Refrigerant System Recovery
NOTE:
Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Prior to recovering the refrigerant system, you must verify the purity of the refrigerant. For additional information, refer to Refrigerant Identification Testing in this section.
2. NOTE: Some R- 134a service centers require the use of an A/C manifold gauge set. For
additional information, refer to Manifold Gauge Set Connection in this section.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
R-
134a A/C Refrigerant Center
176- 00002 or equivalent R-
134a A/C Refrigerant Center
023- 00153 or equivalent R-
134a Manifold Gauge Set
176- R032A or equivalent 1.2 CFM Vacuum Pump
023-
00162 or equivalent 4.0 CFM Vacuum Pump
023-
00163 or equivalent Klj . 1 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3121 of 4378
Connect an R-
134a A/C service center to the low- and high-pressure service gauge port valves.
3. Recover the refrigerant from the system following the operating instructions provided by the equipment manufacturer.
4. Once the service center has recovered the vehicle A/C system refrigerant, close the service center inlet valve (if equipped). Then switch off the power supply.
5. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the vacuum does not decrease, disconnect the
refrigerant center hose(s).
6. If the system vacuum does decrease, repeat Steps 2 through 5 until the vacuum level remains stable for two minutes.
7. Carry out the required repairs.
Refrigerant System Evacuation
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Connect an R- 134a service center to the low- and high-pressure service gauge port valves.
2. Evacuate the system until the low- pressure gauge reads at least 99.4 kPa (29.5 in- Hg) of
vacuum and as close to 101.1 kPa (30 in- Hg) as possible. Continue to operate the vacuum
pump for a minimum of 45 minutes.
3. Turn off the vacuum pump. Observe the low- pressure gauge for five minutes to make sure that
the system vacuum is held. If vacuum is not held for five minutes, leak test the system, service
the leak, and evacuate the system again.
Refrigerant System Charging
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Correctly oil match the system to verify that the correct amount of refrigerant oil is present in the system. For additional information, refer to Refrigerant Oil Adding in this section.
2. Charge the system with the specified amounts of refrigerant oil and refrigerant.
3. When no more refrigerant is being drawn into the system, start the engine and select MAX A/C operation. Adjust the blower motor speed to the maximum and allow the remaining refrigerant to
be drawn into the system. Continue to add refrigerant into the system until the specified weight
of R- 134a has been added. Close the charging cylinder valve and allow the system to pull any
remaining refrigerant from the hose. When the low- pressure drops to approximately 207 kPa
(30 psi), close the charging hose valve. Klj . 2 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3123 of 4378
GENERAL PROCEDURES
Refrigerant System Filtering Following Air Conditioning
(A/C) Component Installation
1. Install the new A/C compressor. For additional information, refer to Section 412 - 03 .
2. Install the new suction accumulator/drier. For additional information, refer to Section 412 - 03 .
3. Install the new A/C evaporator core orifice. For additional information, refer to Section 412 - 03 .
4. Orient the filter inlet toward the A/C condenser core.
5. NOTE: The pancake filter is not permanently installed and will be removed at the end of this
procedure.
Temporarily install the pancake filter between the A/C condenser core and the condenser to
evaporator tube. 1. Use flexible refrigerant hose of 17,238 kPa (2,500 psi) burst rating.
2. Make the connections using the A/C Test Fitting Set.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
Set, A/C Fittings
412-
DS028 (014- 00333, D93L-
19703- B) or equivalent Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3129 of 4378
GENERAL PROCEDURES
Refrigerant Identification Testing
1. NOTE: An A/C refrigerant analyzer must be used to identify gas samples taken directly from the
refrigeration system or storage containers prior to recovering or charging the refrigerant system.
Follow the instructions included with the Deluxe Refrigerant Diagnostic Tool to obtain the
sample for testing.
2. The diagnostic tool will display one of the following: zIf the purity level of R- 134a or R-12 is 98% or greater by weight, the green "PASS" light
emitting diode (LED) will light. The weight concentrations of R- 134a, R-12, R-22,
hydrocarbons, and air will be displayed on the digital display.
z If refrigerants R-134a or R- 12 do not meet the 98% purity levels, the red "FAIL" LED will
light and a horn will sound alerting the user of potential hazards. The weight
concentrations of R-134a, R- 12, R-22, and hydrocarbons will be displayed on the digital
display.
z If hydrocarbon concentrations are 2% or greater by weight, the red "FAIL" LED will light,
"Hydrocarbon High" will be displayed on the digital display, and a horn will sound alerting
the user of potential hazards. The weight concentrations of R- 134a, R-12, R-22, and
hydrocarbons will also be displayed on the digital display.
3. The percentage of air contained in the sample will be displayed if the R- 134a or R-12 content is
98% or greater. The diagnostic tool eliminates the effect of air when determining the refrigerant
sample content because air is not considered a contaminant, although air can affect A/C system
performance. When the diagnostic tool has determined that a refrigerant source is pure (R- 134a
or R- 12 is 98% or greater by weight) and air concentration levels are 2% or greater by weight,
the diagnostic tool will prompt the user if an air purge is desired.
4. If contaminated refrigerant is detected, repeat the refrigerant identification test to verify that the refrigerant is indeed contaminated.
5. CAUTION: If contaminated refrigerant is detected, DO NOT recover the refrigerant
into R- 134a or R- 12 recovery/recycling equipment.
Recover any contaminated refrigerant using suitable recovery- only equipment designed for
capturing and storing contaminated refrigerant. For additional information, refer to
Contaminated Refrigerant Handling in this section.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
Refrigerant Identifier with Air-
Radicator
198-
00003 or equivalent Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3133 of 4378
GENERAL PROCEDURES
Vacuum Hose Repair —
Mini-Tube
1. Measure the length of the damaged area of the mini-tube vacuum hose.
2. Cut a piece of standard 1/8 inch inner diameter vacuum hose approximately 25 mm (1 inch longer than the damaged area of the mini- tube vacuum hose).
3. Cut off the mini-tube vacuum hose on each side of the damaged area.
4. WARNING: Read the warning information on the product label to prevent possible
personal injury.
Dip the mini- tube hose ends in commercially available paint thinner containing methyl ethyl
ketone (MEK). This solvent will seal the mini- tube in the vacuum hose.
5. Insert the ends of the mini- tube vacuum hose approximately 9 mm (3/8 inch) into the ends of
the standard 1/8 inch repair vacuum hose section.
6. Shake the repair joint after assembly to make sure the solvent is dispersed and the vacuum line is not plugged.
7. Test the system for a vacuum leak in the repair area. zUse the Vacuum Tester or equivalent.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
Vacuum Pump Kit
416-
D002 (D95L-7559- A) or
equivalent Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3139 of 4378
DIAGNOSIS AND TESTING
Air Distribution
For additional information, refer to
Section 412 - 00 .
SECTION 412-
01: Air Distribution and Filtering 2003 Mustang Workshop Manual Klj . 1 ba
12003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3158 of 4378
DIAGNOSIS AND TESTING
Heating and Defrosting
Refer to
Section 412 - 00 .
SECTION 412-
02: Heating and Ventilation 2003 Mustang Workshop Manual Klj . 1 ba
12003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...
Page 3166 of 4378
REMOVAL AND INSTALLATION
Heater Core
Removal
NOTE:
If a heater core leak is suspected, the heater core must be pressure leak tested before it is
removed from the vehicle. For additional information, refer to Section 412 - 00 .
1. Remove the evaporator core housing. For additional information, refer to Evaporator Core Housing in this section.
2. Remove the foam weather seal.
3. Remove the screws and remove the heater core cover.
4. Remove the heater core.
Installation 1. NOTE: Be sure to install a new oval foam weather seal around the heater core inlet and outlet
tubes.
To install, reverse the removal procedure.
SECTION 412-
02: Heating and Ventilation 2003 Mustang Workshop Manual Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_5108/S3B~us~en~ ...
Page 3184 of 4378
DIAGNOSIS AND TESTING
Air Conditioning
Refer to
Section 412 - 00 .
SECTION 412-
03: Air Conditioning 2003 Mustang Workshop Manual Klj . 1 ba
12003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_5108/S3B~us~en~ ...