oil FORD MUSTANG 2003 Workshop Manual

Page 3076 of 4378

to plot a vertical line for ambient temperature and a
horizontal line for A/C clutch OFF time in seconds.
z Is the intersection of the two lines above the upper
limit? DISCHARGE and RECOVER
the system to remove
excessive moisture or
refrigerant oil. REFER to
Air Conditioning (A/C) System
Recovery, Evacuation and
Charging . TEST the system
for normal operation.
No
GO to E7 .
E6 CHECK FOR A HIGH SUCTION PRESSURE
z
Refer to the data plot used to evaluate the system low
pressure performance in Step E3.
z Is the intersection of the two lines above the upper
limit? Yes
REMOVE the A/C evaporator
core orifice to repair missing or
damaged (leaking) O-
ring
seals. REFER to Section 412 -
03 . TEST the system for
normal operation.
No
INSTALL a new A/C cycling
switch when the intersection of
the two lines is below the
lower limit. REFER to Section 412 - 03 . TEST the system for
normal operation. E7 CHECK THE AMBIENT TEMPERATURE
z
Refer to the data plot used to evaluate the system A/C
clutch OFF time in Step E5.
z Is the ambient temperature above 26°C (80°F)? Yes
This is normal operation for
the refrigerant system in high
humidity conditions.
No
DISCHARGE and RECOVER
the system to correct an
overcharge condition. REFER
to
Air Conditioning (A/C) System Recovery, Evacuation
and Charging . TEST the
system for normal operation. E8 CHECK FOR A HIGH DISCHARGE PRESSURE
z
Refer to the data plot used to evaluate the system high
pressure performance in Step E2.
z Is the intersection of the two lines above the upper
limit? Yes
GO to
E9 .
No
GO to E11 .
E9 CHECK FOR A NORMAL LOW PRESSURE
z
Use the recorded data from the refrigerant system tests
to plot a vertical line for ambient temperature and a
horizontal line for compressor suction (low) pressure. Yes
REFER to
Section 303 - 03A or
Section 303 - 03B . to diagnose
the engine cooling system.
TEST the system for normal
operation. Klj . 27 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3088 of 4378

A/C Evaporator/Condenser Core—
On-Vehicle Leak Test
1. Discharge and recover the refrigerant. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section.
2. NOTE: DO NOT leak test an A/C evaporator core with the suction accumulator/drier (19C836)
attached to the core tubes.
Disconnect the suspect A/C evaporator core or A/C condenser core from the A/C system. For
additional information, refer to Section 412 - 03 .
3. Clean the spring lock couplings. For additional information, refer to Spring Lock Coupling in this
section.
4. Connect the appropriate test fittings from the A/C Test Fitting Set to the evaporator or condenser tube connections.
5. NOTE: The automatic shut- off valves on some gauge set hoses do not open when connected to
the test fittings. If available, use hoses without shut- off valves. If hoses with shut-off valves are
used, make sure the valve opens when attached to the test fittings or install an adapter which
will activate the valve. The test is not valid if the shut- off valve does not open.
Connect the red and blue hoses from the manifold gauge set to the test fittings on the A/C
evaporator core or A/C condenser core. Connect the yellow hose to a known good vacuum
pump.
6. Open both gauge set valves and start the vacuum pump. Allow the vacuum pump to operate for a minimum of 45 minutes after the gauge set low pressure gauge indicates 101 kPa (30 in- Hg).
The 45- minute evacuation is necessary to remove any refrigerant from oil left in the A/C
evaporator core or A/C condenser core. If the refrigerant is not completely removed from the oil,
outgassing will degrade the vacuum and appear as a refrigerant leak.
7. If the low pressure gauge reading will not drop to 101 kPa (30 in- Hg) when the valves on the
gauge and manifold set are open and the vacuum pump is operating, close the gauge set
valves and observe the low pressure gauge. If the pressure rises rapidly to zero, a large leak is
indicated. Recheck the test fitting connections and gauge set connections before installing a
new A/C evaporator core or A/C condenser core.
8. After evacuating for 45 minutes, close the gauge set valves and stop the vacuum pump. Observe the low pressure gauge; it should remain at the 101 kPa (30 in- Hg) mark.
z If the low pressure gauge reading rises 34 or more kPa (10 or more in- Hg) of vacuum
from the 101 kPa (30 in- Hg) position in 10 minutes, a leak is indicated.
z If a very small leak is suspected, wait 30 minutes and observe the vacuum gauge.
z If a small amount of vacuum is lost, operate the vacuum pump with gauge valves open
for an additional 30 minutes to remove any remaining refrigerant from the oil in the A/C Klj . 39 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3089 of 4378

evaporator core or A/C condenser core. Then recheck for loss of vacuum.
z If a very small leak is suspected, allow the system to sit overnight with vacuum applied
and check for vacuum loss.
9. If the A/C evaporator core or A/C condenser core does leak, as verified by the above procedure, install a new A/C evaporator core or A/C condenser core. For additional information, refer to
Section 412 - 03 .
A/C Compressor— External Leak Test
1. Install the A/C pressure test adapter on the rear head of the A/C compressor using the existing manifold retaining bolt.
2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station such as the R- 134a A/C Service Center to the corresponding fittings
on the A/C pressure test adapter.
3. Attach the center hose of the manifold gauge set to a refrigerant container standing in an upright position.
4. Hand- rotate the compressor shaft 10 complete revolutions to distribute the oil inside the A/C
compressor.
5. Open the low pressure gauge valve, the high pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
6. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft seal and the compressor center seal.
7. If a shaft seal leak is found, install a new shaft seal. For additional information, refer to Section 412 - 03 . If an external leak is found at the center joint of the A/C compressor, install a new A/C
compressor.
8. When the leak test is complete, recover the refrigerant. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section. Klj . 40 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3095 of 4378

Cleaning
1. Fabricate a cleaning tool from a 1/8 inch diameter brazing rod.
2. Cut an abrasive pad from maroon colored 3M Scotch Brite® with the dimensions corresponding to the coupling size.
3. Assemble the pad to the tool.
4. Coat the abrasive pad with PAG Refrigerant Compressor Oil (R- 134a Systems) or equivalent.
5. Roll the pad on the tool and install it in a variable speed drill motor.
6. CAUTION: Maintain low speed drill rotation when inserting or removing the cleaning Coupling Size Pad Size
3/8 inch 25 x 50 mm (1 x 2 inch)
1/2 inch 25 x 50 mm (1 x 2 inch)
5/8 inch 25 x 76 mm (1 x 3 inch)
3/4 inch 25 x 102 mm (1 x 4 inch) Klj . 3 ba
62003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3096 of 4378

tool to prevent axial scratches which may cause future leaks.
Polish for one minute at moderate speed (less than 1,500 rpm) or until the surface is clean and
free of scratches or foreign material.
7. Clean the fitting with a lint- free cloth.
8. Inspect the surface for grooves or scratches. If grooves and scratches are still present, install a new component.
9. Clean the O- ring seal grooves with a 300 mm (12 inch) length of natural fiber string.
z Loop the string around the grooves and pull the string back and forth.
10. Remove any foreign material from the grooves with a lint- free cloth.
Connect 1. Install the A/C tube lock coupling spring.
2. Lubricate the inside of the coupling with PAG Refrigerant Compressor Oil (R- 134a Systems) or
equivalent. Klj . 4 ba
62003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3097 of 4378

3.
CAUTION: Use only the new O- ring seals. The use of any O-ring seals other than
those specified in the Ford Master Parts Catalog may result in intermittent leakage
during vehicle operation.
Install the O- ring seals.
z Lubricate the O- ring seals with PAG Refrigerant Compressor Oil (R- 134a Systems) or
equivalent.
4. Connect the spring lock coupling fittings with a twisting motion until the A/C tube lock coupling spring snaps over the flared end of the female fitting.
5. Install the A/C tube lock coupling clip. Klj . 5 ba
62003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3103 of 4378

Connect
1. Clean all dirt or foreign material from the fittings.
2. CAUTION: Use only the new O- ring seals. The use of any O-ring seals other than
those specified in the Ford Master Parts Catalog may result in intermittent leakage
during vehicle operation.
Install the O- ring seal.
z Lubricate the O- ring seal with PAG Refrigerant Compressor Oil (R- 134a Systems) F7AZ-
19589- DA (Motorcraft YN-12- C) or equivalent meeting Ford specification WSH-M1C231-
B.
3. Lubricate the inside of the fittings with PAG Refrigerant Compressor Oil (R- 134a Systems)
F7AZ- 19589- DA (Motorcraft YN-12- C) or equivalent meeting Ford specification WSH-M1C231-
B.
4. NOTE: When correctly assembled, the male and female fittings should be flush.
Assemble the male and female fittings together. Klj . 2 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3115 of 4378

GENERAL PROCEDURES
Tracer Dye Leak Detection
NOTE:
Ford Motor Company vehicles are produced with a permanent leak tracer dye incorporated into
the A/C system. The location of leaks can be pinpointed by the bright yellow- green glow of the tracer
dye. Since more than one leak can exist, always inspect each component.
1. Check for leaks using a 120 Watt UV spot lamp. zScan all components, fittings and lines of the A/C system.
2. After the leak is repaired, remove any traces of tracer dye with a general purpose oil solvent.
3. Verify the repair by operating the system for a short time and inspect with the UV spot lamp.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
120 Watt 110 Volt UV Lamp
20°C
164-
R0721 or equivalent Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3118 of 4378

Ford Motor Company has approved a procedure to provide technicians with a non-
CFC method
of flushing contaminated A/C system heat exchangers, A/C evaporator core, and A/C
condenser core. The procedure allows the specific components to be cleaned and flushed while
installed in their normal in- vehicle location. The types of contamination flushed include particle
matter that results from A/C compressor or desiccant failure within the suction accumulator/drier
and gummy residue that can form when refrigerant oil is overheated during A/C compressor
seizure. The flushing process is a two- step procedure that involves the use of an A/C Flush and
Purge Machine 219- 00022 to:
z Circulate the flushing solvent through the heat exchanger in the reverse direction of
normal refrigerant flow (back- flushing). Particulate matter picked up during flushing is
filtered from the returning solvent before the solvent is returned to the reservoir for
continued circulation.
z Remove the flushing solvent from the heat exchanger. In this step of the procedure,
pressurized air 621- 862 kPa (90-125 psi) is used to push and evaporate any remaining
flush solvent from the heat exchanger.
2. Discharge the A/C system. Observe all safety precautions. For additional information, refer to the procedure in this section.
3. Disconnect the refrigerant lines from the heat exchanger(s) to be flushed.
4. Connect the A/C Flush and Purge Machine 219- 00022 and A/C Flush and Purge Fitting Kit 219-
00024 to the heat exchanger to be flushed. Do not flush through the A/C evaporator core orifice,
mufflers or hoses. Internal plumbing and material make- up of these components make it
impossible to correctly remove foreign material or residual flushing solvent.
5. Use 3.785 liters (one gallon) of A/C Systems Flushing Solvent part number F4AZ-19579- A to
flush the heat exchanger for a minimum of 15 minutes. The flush solvent may be used for one
or both heat exchangers in the A/C system. However, the flush solvent is intended for one
vehicle only. The filter used on the flushing unit is also intended for use on one vehicle only.
6. Flush the component for a minimum of 15 minutes.
7. Apply 621- 862 kPa (90-125 psi) pressurized air to the component for a minimum of 30 minutes.
The 30- minute purge time is required to force and evaporate all residual solvent from the A/C
system component. Failure to successfully remove all residual solvent within the component
can result in system damage when reconnected and operated. Dispose of the used flush
solvent and filter in accordance with local, state and federal emissions.
8. NOTE: A/C system filtering as described in this section is optional if system flushing is carried
out. However, the filter kit use is recommended after flushing if the A/C system contamination is
extensive.
Install a new A/C evaporator core orifice in any vehicle being serviced for A/C compressor or
desiccant failure.
9. Install new refrigerant hoses if clogged with foreign material.
10. Reconnect the heat exchanger being serviced.
11. Add additional refrigerant oil as required. For additional information, refer to the procedure in this section.
12. Evacuate, leak test and charge the A/C system. For additional information, refer to the procedure in this section.
13. Check the system for normal operation. Klj . 2 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3121 of 4378

Connect an R-
134a A/C service center to the low- and high-pressure service gauge port valves.
3. Recover the refrigerant from the system following the operating instructions provided by the equipment manufacturer.
4. Once the service center has recovered the vehicle A/C system refrigerant, close the service center inlet valve (if equipped). Then switch off the power supply.
5. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the vacuum does not decrease, disconnect the
refrigerant center hose(s).
6. If the system vacuum does decrease, repeat Steps 2 through 5 until the vacuum level remains stable for two minutes.
7. Carry out the required repairs.
Refrigerant System Evacuation
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Connect an R- 134a service center to the low- and high-pressure service gauge port valves.
2. Evacuate the system until the low- pressure gauge reads at least 99.4 kPa (29.5 in- Hg) of
vacuum and as close to 101.1 kPa (30 in- Hg) as possible. Continue to operate the vacuum
pump for a minimum of 45 minutes.
3. Turn off the vacuum pump. Observe the low- pressure gauge for five minutes to make sure that
the system vacuum is held. If vacuum is not held for five minutes, leak test the system, service
the leak, and evacuate the system again.
Refrigerant System Charging
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Correctly oil match the system to verify that the correct amount of refrigerant oil is present in the system. For additional information, refer to Refrigerant Oil Adding in this section.
2. Charge the system with the specified amounts of refrigerant oil and refrigerant.
3. When no more refrigerant is being drawn into the system, start the engine and select MAX A/C operation. Adjust the blower motor speed to the maximum and allow the remaining refrigerant to
be drawn into the system. Continue to add refrigerant into the system until the specified weight
of R- 134a has been added. Close the charging cylinder valve and allow the system to pull any
remaining refrigerant from the hose. When the low- pressure drops to approximately 207 kPa
(30 psi), close the charging hose valve. Klj . 2 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page:   < prev 1-10 ... 491-500 501-510 511-520 521-530 531-540 541-550 551-560 561-570 571-580 ... 620 next >