GENESIS GV60 2023 Workshop Manual
Page 51 of 690
1-46
Foreword / Starting your Electric vehicle
Indicator Details
Error code
On : Error while charging/ Error during self-diagnosis
Error code Item Cause
E1Control Pilot
communicationVehicle communication error
E2
LeakageCurrent leakage
E3 Charger error
E4
Plug temperaturePlug overtemperature
warning
E5 Plug temperature failure
E6 Charger error
E7 Overcurrent Charging overcurrent warning
E8
Internal
temperatureCharger overheating
E9 Charger error
F1 Relay fusion Charger error
F2Ground
Monitoring/
InterruptPoor grounding of outlet
F3
Switched mode
power supply
power failureSwitched mode power supply
error (voltage failure)
F4Switched mode power supply
error (abnormal voltage)
F5
Control Pilot
voltage errorControl Pilot (-) voltage error
F6 Control Pilot (+) voltage error
F7
Temperature
sensor errorPlug temperature sensor error
F8PCB internal temperature
sensor error
Page 52 of 690
1-47
01
Indicator Details
CHARGE
LEVEL
12 A
10 A
8 A
6 A
The charging current changes whenever the
button (1) is pressed for less than 1 sec with
the charger plugged into an electrical outlet
but not the vehicle.* The control box
ORG3EVQ011075