fuse INFINITI FX35 2004 Service Manual

Page 3618 of 4449

AUTO LIGHT SYSTEM
LT-63
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
CONSULT-II Functions (BCM)AKS007I5
CONSULT-II executes the following functions by combining data reception and command transmission via
the communication line from BCM. Work support, self-diagnosis, data monitor, and active test display.
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E
BCM diagnosis part Check item, diagnosis mode Description
HEADLAMPWORK SUPPORT Changes the setting for each function.
DATA MONITOR Displays BCM input data in real time.
ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
BCM CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read.

Page 3632 of 4449

FRONT FOG LAMP
LT-77
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
FRONT FOG LAMPPFP:26150
Component Parts and Harness Connector LocationAKS007O5
System DescriptionAKS007CI
Control of the fog lamps is dependent upon the position of the combination switch (lighting switch). The light-
ing switch must be in the 2ND position or AUTO position (LOW beam is ON) for front fog lamp operation.
When the lighting switch is placed in the fog lamp position the BCM (body control module) receives input sig-
nal requesting the fog lamps to illuminate. When the headlamps are illuminated, this input signal is communi-
cated to the IPDM E/R (intelligent power distribution module engine room) across the CAN communication
lines. The central processing unit of the IPDM E/R controls the front fog lamp relay coil. When activated, this
relay directs power to the front fog lamps.
OUTLINE
Power is supplied at all times
to ignition relay [located in IPDM E/R (intelligent power distribution module engine room)]
through 15A fuse [No. 88, located in IPDM E/R (intelligent power distribution module engine room)]
to front fog lamp relay [located in IPDM E/R (intelligent power distribution module engine room)]
through 15A fuse [No. 78, located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine room)]
through 10A fuse [No. 71, located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
Power is also supplied at all times
through 50A fusible link (letter M, located in the fuse and fusible link block)
to BCM (body control module) terminal 55
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM (body control module) terminal 42.
When the ignition switch is in ON or START position, power is supplied
PKIA5269E

Page 3633 of 4449

LT-78
FRONT FOG LAMP
Revision: 2004 November 2004 FX35/FX45
to ignition relay [located in IPDM E/R (intelligent power distribution module engine room)]
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38.
When the ignition switch is in ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM (body control module) terminal 11.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds M35, M45 and M85
to IPDM E/R (intelligent power distribution module engine room) terminals 38 and 60
through grounds E21, E50 and E51.
Fog Lamp Operation
The fog lamp switch is built into the combination switch. The lighting switch must be in the 2ND position or
AUTO position (LOW beam is ON) and the fog lamp switch must be ON for fog lamp operation.
With the fog lamp switch in the ON position, the CPU of the IPDM E/R grounds the coil side of the fog lamp
relay. The fog lamp relay then directs power
through IPDM E/R terminal 37
to front fog lamp LH terminal 1
through IPDM E/R terminal 36
to front fog lamp RH terminal 1.
Ground is supplied
to front fog lamp LH terminal 2
through grounds E21, E50 and E51, and
to front fog lamp RH terminal 2
through grounds E21, E50 and E51.
With power and grounds supplied, the front fog lamps illuminate.
COMBINATION SWITCH READING FUNCTION
Refer to BCS-3, "COMBINATION SWITCH READING FUNCTION" .
EXTERIOR LAMP BATTERY SAVER CONTROL
When the combination switch (lighting switch) is in the 2ND position (ON), the fog lamp switch is ON, and the
ignition switch is turned from ON or ACC to OFF, the battery saver control feature is activated.
Under this condition, the fog lamps (and headlamps) remain illuminated for 5 minutes, then the fog lamps (and
headlamps) are turned off.
Exterior lamp battery saver control mode can be changed by the function setting of CONSULT-II.
CAN Communication System DescriptionAKS007CJ
CAN (Controller Area Network) is a serial communication line for real time application. It is an on-vehicle mul-
tiplex communication line with high data communication speed and excellent error detection ability. Many elec-
tronic control units are equipped onto a vehicle, and each control unit shares information and links with other
control units during operation (not independent). In CAN communication, control units are connected with 2
communication lines (CAN H line, CAN L line) allowing a high rate of information transmission with less wiring.
Each control unit transmits/receives data but selectively reads required data only.
CAN Communication UnitAKS0080V
Refer to LAN-6, "CAN Communication Unit" .

Page 3637 of 4449

LT-82
FRONT FOG LAMP
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Values for IPDM E/RAKS007CN
How to Proceed With Trouble DiagnosisAKS007CO
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 7 7 , "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 8 2 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the front fog lamp operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. INSPECTION END
Preliminary CheckAKS007CP
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check fuses for blown-out.
35 W/G Combination switch output 2
ONLighting, turn, wiper OFF
Wiper dial position 4
36 W/R Combination switch output 1
38 W/L Ignition switch (ON) ON — Battery voltage
39 L CAN− H—— —
40 R CAN− L—— —
42 L/R Battery power supply OFF — Battery voltage
49 B Ground ON — Approx. 0V
52 B Ground ON — Approx. 0V
55 G Battery power supply OFF — Battery voltage Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
Ignition
switchOperation or condition
SKIA5292E
Terminal
No.Wire
colorSignal
nameMeasuring condition
Reference value
Ignition
switchOperation or condition
36 WFront fog
lamp (RH) ONLighting switch must be in the 2ND position or AUTO position
(LOW beam is ON) and the front fog lamp switch must be ON.OFF Approx. 0V
ON Battery voltage
37 SBFront fog
lamp (LH)ONLighting switch must be in the 2ND position or AUTO position
(LOW beam is ON) and the front fog lamp switch must be ON.OFF Approx. 0V
ON Battery voltage
38 B Ground ON — Approx. 0V
48 L CAN− H— — —
49 R CAN− L— — —
60 B Ground ON — Approx. 0V
Unit Power source Fuse and fusible link No.
BCMBatteryM
22
Ignition switch ON or START position 1
Ignition switch ACC or ON position 6

Page 3638 of 4449

FRONT FOG LAMP
LT-83
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Refer to LT-79, "Wiring Diagram — F/FOG —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
CONSULT-II FunctionsAKS007CQ
Refer to LT- 1 8 , "CONSULT-II Functions (BCM)" in HEAD LAMP.
Refer to LT- 2 1 , "
CONSULT-II Functions (IPDM E/R)" in HEAD LAMP.
IPDM E/R Battery71
78
88 Unit Power source Fuse and fusible link No.
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E

Page 3644 of 4449

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-89
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
TURN SIGNAL AND HAZARD WARNING LAMPSPFP:26120
Component Parts and Harness Connector LocationAKS007O6
System DescriptionAKS007CW
OUTLINE
Power is supplied at all times
through 50A fusible link (letter M, located in fuse and fusible link block)
to BCM (body control module) terminal 55
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM (body control module) terminal 42
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8.
TURN SIGNAL OPERATION
When the ignition switch is in the ON or START position, power is supplied
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38
through 10A fuse [No. 14, located in fuse block (J/B)]
to combination meter terminal 7.
When the ignition switch is in the ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM (body control module) terminal 11.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds M35, M45 and M85
PKIA6523E

Page 3645 of 4449

LT-90
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: 2004 November 2004 FX35/FX45
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85.
LH Turn
When the turn signal switch is moved to the left position, BCM output turn signal from BCM terminal 45, inter-
preting it as turn signal is ON.
Connected from BCM terminal 45 to front combination lamp LH terminal 4.
Turn signal lamp turns on
through front combination lamp LH terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminal 45 to rear combination lamp control unit terminal 4.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, Rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
RH Turn
When the turn signal switch is moved to the right position, BCM output turn signal from BCM terminal 46, inter-
preting it as turn signal is ON.
Connected from BCM terminal 46 to front combination lamp RH terminal 4.
Turn signal lamp turns on
through front combination lamp RH terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminal 46 to rear combination lamp control unit terminal 5.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 9
to rear combination lamp RH terminal 3
through rear combination lamp RH terminal 4
to rear combination lamp control unit terminal 8.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, Rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
HAZARD LAMP OPERATION
Power is supplied at all times
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM terminal 55
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
Ground is supplied
through BCM terminals 49 and 52
to grounds M35, M45 and M85

Page 3646 of 4449

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-91
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
through rear combination lamp control unit terminal 7
to grounds E21, E50 and E51
through combination meter terminals 5, 6 and 15
to grounds M35, M45 and M85.
When the hazard switch is depressed, ground is supplied
through BCM terminal 29
to hazard switch terminal 2
through hazard switch terminal 1
to grounds M35, M45 and M85.
When the hazard switch is depressed, BCM output turn signal from BCM terminals 45 and 46, interpreting it as
turn signal is ON.
Connected from BCM terminal 45 and 46 to front combination lamp terminal 4.
Turn signal lamp turns on
through front combination lamp terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminals 45 and 46 to rear combination lamp control unit terminals 4 and 5.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10
through rear combination lamp control unit terminal 9
to rear combination lamp RH terminal 3
through rear combination lamp RH terminal 4
to rear combination lamp control unit terminal 8.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
REMOTE CONTROL ENTRY SYSTEM OPERATION
Power is supplied at all times
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM terminal 55
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
Ground is supplied
to BCM terminals 49 and 52
through grounds M35, M45 and M85
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85.
When the remote control entry system is triggered by input from the keyfob, BCM output turn signal from BCM
terminals 45 and 46, interpreting it as turn signal is ON.
Connected from BCM terminals 45 and 46 to front combination lamp terminal 4,
turn signal lamp turns on
through front combination lamp terminal 8
to grounds E21, E50 and E51.

Page 3654 of 4449

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-99
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Preliminary CheckAKS007D3
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check fuses for blown-out.
Refer to LT-94, "Wiring Diagram — TURN —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
Unit Power source Fuse and fusible link No.
BCMBatteryM
22
Ignition switch ON or START position 1
Ignition switch ACC or ON position 6
Rear combination lamp control unit Battery 20
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E

Page 3676 of 4449

STOP LAMP
LT-121
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Stop Lamp Does Not OperateAKS007IJ
1. CHECK TAIL LANP AND TURN SIGNAL LAMP
Make sure tail lamps and turn signal lamps are illuminated.
OK or NG
OK >> GO TO 2.
NG >> GO TO 6.
2. CHECK FUSE
Check fuse No. 20 is blow out.
OK or NG
OK >> GO TO 3.
NG >> If fuse is blow out, be sure to eliminate cause of malfunction before installing new fuse.
3. CHECK INPUT SIGNAL
Check voltage between rear combination lamp control unit harness
connector B65 terminal 3 (P) and ground.
OK or NG
OK >> Replace rear combination lamp control unit.
NG >> GO TO 4.
4. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch connector.
3. Check voltage between stop lamp switch harness connector
E210 terminal 1 (GY) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK STOP LAMP SWITCH CIRCUIT
1. Disconnect rear combination lamp control unit connector.
2. Check continuity between stop lamp switch harness connector
E210 terminal 2 (P) and rear combination lamp control unit har-
ness connector B65 terminal 3 (P).
OK or NG
OK >> Replace stop lamp switch.
NG >> Repair harness or connector.
Terminals
(-) Condition Voltage
ConnectorTerminal
(Wire color)
B65 3 (P) GroundStop lamp switch is ON.
(Depressed)Battery voltage
Stop lamp switch is OFF.
(Released)Approx. 0
PKIA5233E
1 (GY) – Ground : Battery voltage should exist.
PKIA5234E
2 (P) – 3 (P) : Continuity should exist.
PKIA5235E

Page:   < prev 1-10 ... 101-110 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 ... 210 next >