fuse INFINITI FX35 2004 Service Manual

Page 3682 of 4449

PARKING, LICENSE PLATE AND TAIL LAMPS
LT-127
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
PARKING, LICENSE PLATE AND TAIL LAMPSPFP:26550
Component Parts and Harness Connector LocationAKS007O7
System DescriptionAKS007DT
Control of the parking, license plate, and tail lamp operation is dependent upon the position of the lighting
switch (combination switch). When the lighting switch is placed in the 1ST position, the BCM (body control
module) receives input signal requesting the parking, license plate, side marker and tail lamps to illuminate.
This input signal is communicated to the IPDM E/R (intelligent power distribution module engine room) across
the CAN communication lines. The CPU (central processing unit) of the IPDM E/R (intelligent power distribu-
tion module engine room) controls the tail lamp relay coil. This relay, when energized, directs power to the
parking, license plate, side marker and tail lamps, which then illuminate.
The current that flows by Rear combination lamp unit is controlled, and a tail lamp (LED) is made to turn on.
Power is supplied at all times
through 10A fuse [No. 71, located in IPDM E/R (intelligent power distribution module engine room)]
to tail lamp relay [located in IPDM E/R (intelligent power distribution module engine room)] and
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
through 15A fuse [No. 78, located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
Power is also supplied at all times
through 50A fusible link (letter M, located in the fuse and fusible link block)
to BCM (body control module) terminal 55
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM (body control module) terminal 42
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
With the ignition switch in the ON or START position, power is supplied
PKIA5272E

Page 3683 of 4449

LT-128
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: 2004 November 2004 FX35/FX45
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38
through ignition relay [located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM (body control module) terminal 11.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds M35, M45 and M85
to IPDM E/R (intelligent power distribution module engine room) terminals 38 and 60
through grounds E21, E50 and E51
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51.
OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position (or if the auto light system is activated), the BCM receives
input signal requesting the parking, license plate, side marker and tail lamps to illuminate. This input signal is
communicated to the IPDM E/R across the CAN communication lines. The CPU in the IPDM E/R controls the
tail lamp relay coil, which when energized, directs power
through IPDM E/R terminal 22
to front side marker lamp LH terminal 1
to clearance lamp LH terminal 2
to license plate lamp LH terminal 1
to rear combination lamp LH terminal 1
to rear combination lamp control unit terminal 2
to front side marker lamp RH terminal 1
to clearance lamp RH terminal 2
to license plate lamp RH terminal 1
to rear combination lamp RH terminal 1.
Ground is supplied at all times
to front side marker lamp LH terminal 2
through grounds E21, E50 and E51
to clearance lamp LH terminal 3
through grounds E21, E50 and E51
to license plate lamp LH terminal 2
through grounds B15 and B45
to rear combination lamp LH terminal 2
through grounds B15 and B45
to front side marker lamp RH terminal 2
through grounds E21, E50 and E51
to clearance lamp RH terminal 3
through grounds E21, E50 and E51
to license plate lamp RH terminal 2
through grounds B15 and B45
to rear combination lamp RH terminal 2
through grounds B203 and B210
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51.

Page 3692 of 4449

PARKING, LICENSE PLATE AND TAIL LAMPS
LT-137
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Values for IPDM E/RAKS007IM
How to Proceed With Trouble DiagnosisAKS007E0
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 1 2 7 , "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 1 3 7 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Do the parking, license and tail lamps operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. INSPECTION END
Preliminary CheckAKS007E1
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check fuses for blown-out.
35 W/G Combination switch output 2
ONLighting, turn, wiper OFF
Wiper dial position 4
36 W/R Combination switch output 1
38 W/L Ignition switch (ON) ON — Battery voltage
39 L CAN− H—— —
40 R CAN− L—— —
42 L/R Battery power supply OFF — Battery voltage
49 B Ground ON — Approx. 0V
52 B Ground ON — Approx. 0V
55 G Battery power supply OFF — Battery voltage Te r m i n a l
No.Wire
colorSignal nameMeasuring condition
Reference value
Ignition switch Operation or condition
SKIA5292E
Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
Ignition
switchOperation or condition
22 RParking, license,
and tail lampONLighting switch
1ST positionOFF Approx. 0V
ON Battery voltage
38 B Ground ON — Approx. 0V
48 L CAN− H—— —
49 R CAN− L—— —
60 B Ground ON — Approx. 0V
Unit Power source Fuse and fusible link No.
BCMBatteryM
22
Ignition switch ON or START position 1
Ignition switch ACC or ON position 6
IPDM E/R Battery71
78
Rear combination lamp control unit Battery 20

Page 3693 of 4449

LT-138
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: 2004 November 2004 FX35/FX45
Refer to LT- 1 3 1 , "Wiring Diagram — TAIL/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
CONSULT-II FunctionsAKS007E2
Refer to LT- 1 8 , "CONSULT-II Functions (BCM)" in HEAD LAMP.
Refer to LT- 2 1 , "
CONSULT-II Functions (IPDM E/R)" in HEAD LAMP.
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E

Page 3712 of 4449

INTERIOR ROOM LAMP
LT-157
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
INTERIOR ROOM LAMPPFP:26410
Component Parts and Harness Connector LocationAKS007O8
System DescriptionAKS007F7
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch, front door switch driver side,
unlock signal from keyfob, door lock and unlock switch, key cylinder lock and unlock switch, ignition switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON at time when driver door is opened (door switch ON) or removed keyfob
from key cylinder. Illumination turns OFF when driver door is closed (door switch OFF).
Step lamp turns ON at time when driver door or passenger door is opened (door switch ON). Lamp turns OFF
when driver, passenger doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times (without intelligent key system)
through 15A fuse [No. 22, located in fuse block (J/B)]
to key switch terminal 2 and
to BCM (body control module) terminal 42
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM (body control module) terminal 55.
Power is supplied at all times (with intelligent key system)
through 10A fuse [No.38, located in fuse and fusible link block]
to key switch and ignition knob switch terminals 1
through 15A fuse [No.22, located in fuse block (J/B)]
to BCM (body control module) terminal 42
to key switch and ignition knob switch terminal 3, and
to key switch terminal 2
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM (body control module) terminal 55.
When the key plate inserted to key switch, power is supplied (without intelligent key system)
through the key switch terminal 1
to BCM (body control module) terminal 37.
PKIA2923E

Page 3713 of 4449

LT-158
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
When inserted the key plate to key switch, power is supplied (with intelligent key system)
through the key switch and ignition knob switch terminal 4
to BCM (body control module) terminal 37.
When moved the ignition knob switch, power is supplied (with intelligent key system)
through the ignition knob switch terminal 2
to intelligent key unit terminal 27.
With the ignition switch in the ON or START position, power is supplied
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds terminals M35, M45 and M85.
When the driver side door is opened, ground is supplied
through case ground of door switch driver side
to BCM (body control module) terminal 62.
When the passenger side door is opened, ground is supplied
through case ground of door switch passenger side
to BCM (body control module) terminal 12.
When the rear door LH is opened, ground is supplied
through case ground of door switch rear door LH
to BCM (body control module) terminal 63, and
to personal lamp LH terminal 1.
When the rear door RH is opened, ground is supplied
through case ground of door switch rear door RH
to BCM (body control module) terminal 13, and
to personal lamp RH terminal 1.
When the driver side door is unlocked by the door lock and unlock switch, BCM (body control module)
receives a ground signal
through grounds terminals M35, M45 and M85
to power window main switch terminal 17 (door lock and unlock switch) or front power window (passenger
side) terminal 11 (door lock and unlock switch)
from power window main switch terminal 14 (door lock and unlock switch) or front power window (passen-
ger side) terminal 16 (door lock and unlock switch)
to BCM (body control module) terminal 22.
When the front driver side door is unlocked by the driver side door lock assembly (door key cylinder switch),
BCM (body control module) receives a ground signal
through grounds M35, M45 and M85
to front door lock assembly (driver side) (door key cylinder switch) terminal 5
from front door lock assembly (driver side) (door key cylinder switch) terminal 6
to power window main switch terminal 6 (door lock and unlock switch)
from power window main switch terminal 14 (door lock and unlock switch)
to BCM (body control module) terminal 22.
When a signal, or combination of signals is received by BCM (body control module), ground is supplied
through BCM (body control module) terminal 48
to interior room lamp terminal 1(without DVD player),
to map lamp terminal 2 and
to front door inside handle illumination (driver side and passenger side) terminal 2
With power and supplied, the interior lamp illuminates.

Page 3714 of 4449

INTERIOR ROOM LAMP
LT-159
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
SWITCH OPERATION
When driver door switch is ON (door is opened), ground is supplied
through BCM terminal 1
to ignition keyhole illumination terminal 2.
And power is supplied
from BCM terminal 41
to ignition keyhole illumination terminal 1.
When any door switch is ON (door is opened), ground is supplied
through BCM terminal 47
to front step lamp driver side and passenger side, rear step lamp (LH and RH)
through rear door switch terminal 1
to personal lamp (LH and RH) terminal 1.
And power is supplied
from BCM terminal 41
to every step lamp terminal 1, and personal lamp (LH and RH) terminal 2.
When map lamp switch is ON, ground is supplied
through grounds M35, M45 and M85
to map lamp terminal 1.
And power is supplied
from BCM terminal 41
to map lamp terminal 3.
When vanity mirror lamp (driver side and passenger side) is ON, ground is supplied
through grounds M35, M45 and M85
to vanity mirror lamp (driver side and passenger side) terminal 2.
And power is supplied
from BCM terminal 41
to vanity mirror lamp (driver side and passenger side) terminal 1.
When luggage room lamp (back door side) is ON, ground is supplied
through grounds B15 and B45
to luggage room lamp (back door side) terminal 3.
And power is supplied
from BCM terminal 41
to luggage room lamp (body side and back door side) terminal 2.
ROOM LAMP TIMER OPERATION
Without Intelligent Key System
When interior room lamp and map lamp switch is in DOOR position, and when all conditions below are met,
BCM performs timer control (maximum 30 seconds) for interior room lamp and map lamp ON/OFF.
In addition, when spot turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
to 15A fuse [No. 22, located in fuse block (J/B)]
through key switch terminal 2.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Ground is supplied
from BCM terminal 22
to power window main switch (door lock and unlock switch) terminal 14.
At the time that driver door are opened, BCM detects that driver door is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamp and map lamp
ON for 30 seconds.
Key is in ignition key cylinder (key switch ON),
Power is supplied

Page 3715 of 4449

LT-160
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
through key switch terminal 1
to BCM terminal 37.
When key is removed from key switch (key switch OFF), power supply to BCM terminal 37 is terminated. BCM
detects that key has been removed, determines that interior room lamp and map lamp timer conditions are
met, and turns the interior room lamp and map lamp ON for 30 seconds.
When driver door opens → closes, and the key is not inserted in the key switch (key switch OFF), BCM termi-
nal 62 changes between 0V (door open) → 12V (door closed). The BCM determines that conditions for inte-
rior room lamp and map lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Driver door is locked [when locked keyfob or power window main switch (door lock and unlock switch),
door key cylinder switch].
Driver door is opened (driver door switch turns ON).
Ignition switch ON.
With Intelligent Key System
When interior room lamp and map lamp switch is in DOOR position, and when all conditions below are met,
BCM performs timer control (maximum 30 second) for interior room lamp and map lamp ON/OFF.
In addition, when spot turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
to 15A fuse [No. 22, located in fuse and fuse block (J/B)]
through key switch and ignition knob switch terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
And not turned ignition knob switch, power will not be supplied to Intelligent Key unit.
Ground is supplied
from BCM terminal 22
to power window main switch (door lock and unlock switch) terminal 14.
At the time that driver door are opened, BCM detects that driver door is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamp and map lamp
ON for 30 seconds.
Key is in ignition key cylinder (key switch ON), or turned ignition knob switch,
Power is supplied
through key switch and ignition knob switch terminal 4
to BCM terminal 37
through key switch and ignition knob switch terminal 2
to Intelligent Key unit terminal 27.
When key is removed from key switch (key switch OFF), power supply to BCM terminal 37 is terminated. And
turned ignition knob switch, power supply to intelligent key unit is terminated. BCM detects that key has been
removed, determines that interior room lamp and map lamp timer conditions are met, and turns the interior
room lamp and map lamp ON for 30 seconds.
When driver door opens → closes, and the key is not inserted in the key switch (or not turned ignition knob
switch), BCM terminal 62 changes between 0V (door open) → 12V (door closed). The determines that condi-
tions for interior room lamp and map lamp operation are met and turns the interior room lamp ON for 30 sec-
onds.
Timer control is canceled under the following conditions.
Driver door is locked [when locked keyfob or power window main switch (door lock and unlock switch).
door key cylinder switch].
Driver door is opened (driver door switch terns ON).
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned out even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Luggage room lamp
Vanity mirror lamp
Map lamp

Page 3728 of 4449

INTERIOR ROOM LAMP
LT-173
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
How to Proceed With Trouble DiagnosisAKS007FC
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 1 5 7 , "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 1 7 3 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the interior room lamp operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. INSPECTION END
Preliminary CheckAKS007FD
CHECK FOR POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check for blown BCM fuses.
Refer to LT-164, "Wiring Diagram — ROOM/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM and ground.
OK or NG
OK >> INSPECTION END
NG >> Check harness ground circuit.
Unit Power source Fuse and fusible link No.
BCMBatteryM
22
Ignition switch ON or START position 1
Terminals Ignition switch position
(+)
(-) OFF ON
Connector Terminal (Wire color)
M442 (L/R)
GroundBattery voltage Battery voltage
55 (G) Battery voltage Battery voltage
M3 38 (W/L) 0V Battery voltage
PKIA5271E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E

Page 3740 of 4449

ILLUMINATION
LT-185
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
ILLUMINATIONPFP:27545
System DescriptionAKS007EI
Control of the illumination lamps operation is dependent upon the position of the lighting switch (combination
switch). When the lighting switch is placed in the 1ST or 2ND position (or if the auto light system is activated)
the BCM (body control module) receives input signal requesting the illumination lamps to illuminate. This input
signal is communicated to the IPDM E/R (intelligent power distribution module engine room) across the CAN
communication lines. The CPU (central processing unit) of IPDM E/R (intelligent power distribution module
engine room) controls the tail lamp relay coil. This relay, when energized, directs power to the illumination
lamps, which then illuminate.
Power is supplied at all times
to tail lamp relay [located in IPDM E/R (intelligent power distribution module engine room)]
through 10A fuse [No. 71, located in IPDM E/R (intelligent power distribution module engine room)].
Power is also supplied at all times
to BCM (body control module) terminal 55
through 50A fusible link (letter M, located in fuse and fusible link block)
to BCM (body control module) terminal 42
through 15A fuse [No. 22, located in fuse block (J/B)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine room)]
through 15A fuse [No. 78, located in IPDM E/R (intelligent power distribution module engine room)]
to unified meter and A/C amp. terminal 21 and
to combination meter terminal 8
through 10A fuse [No. 19, located in fuse block (J/B)].
With the ignition switch in the ON or START position, power is supplied
to BCM (body control module) terminal 38
through 15A fuse [No. 1, located in fuse block (J/B)]
to unified meter and A/C amp. terminal 22
through 10A fuse [No. 12, located in fuse block (J/B)]
to ignition relay in the IPDM E/R (intelligent power distribution module engine room)
from ignition switch
to combination meter terminal 7
through 10A fuse [No. 14, located in fuse block (J/B)].
With the ignition switch in the ACC or ON position, power is supplied
to BCM (body control module) terminal 11
through 10A fuse [No. 6, located in fuse block (J/B)].
Ground is supplied
to BCM (body control module) terminals 49 and 52
to unified meter and A/C amp. terminals 29 and 30, and
to combination meter terminals 5, 6, and 15
through grounds M35, M45, and M85
to IPDM E/R (intelligent power distribution module engine room) terminals 38 and 60
through grounds E21, E50, and E51.
ILLUMINATION OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position (or if the auto light system is activated), the BCM receives
input signal requesting the illumination lamps to illuminate. This input signal is communicated to the IPDM E/R
across the CAN communication lines. The central processing unit of the IPDM E/R controls the tail lamp relay
coil, which, when energized, directs power
through IPDM E/R terminal 22
to glove box lamp terminal 1
to A/T device (illumination) terminal 11
to snow mode switch (illumination) terminal 4

Page:   < prev 1-10 ... 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 191-200 ... 210 next >