INFINITI FX35 2006 Service Manual

Page 4211 of 4462

AUTOMATIC DRIVE POSITIONER SE-73
C
D E
F
G H
J
K L
M A
B
SE
Revision: 2006 December 2006 FX35/FX45
Check Telescopic Switch CircuitNIS001VQ
1. CHECK FUNCTION
With CONSULT-II
With “TELESCO SW-FR, TELESCO SW-RR” on the DATA MONITOR, operate the ADP steering switch to
check ON/OFF operation.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Telescopic switch operate, check voltage between automatic drive positioner control unit connector and ground.
OK or NG
OK >> Telescopic switch circuit is OK.
NG >> GO TO 2.
2. CHECK TELESCOPIC CIRCUIT HARNESS CONTINUITY
1. Disconnect automatic drive positioner control unit connector and ADP steering switch connector.
2. Check continuity between automatic drive positioner control unit connector M49 terminals 11, 27 and ADP steering switch con-
nector M13 terminals 4, 5.
3. Check continuity between automatic drive positioner control unit connector M49 terminals 11, 27 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between automatic drive positioner control unit and ADP steering switch.
Monitor item
[OPERATION or UNIT] Contents
TELESCO SW-FR “ON/OFF” (ON/OFF) status judged from the telescoping
switch (FR) signal is displayed.
TELESCO SW-RR “ON/OFF” (ON/OFF) status judged from the telescoping
switch (RR) signal is displayed.
PIIA0315E
Connector Terminals
(Wire color) Telescopic switch condition Voltage (V)
(Approx.)
(+) (–)
M49 11 ( B R )
Ground FORWARD 0
Other than above 5
27 (LG) BACKWARD 0
Other than above 5
PIIA5073E
11 (BR) – 5 (BR) : Continuity should exist.
27 (LG) – 4 (LG) : Continuity should exist.
11 (BR) – Ground : Continuity should not exist.
27 (LG) – Ground : Continuity should not exist.
PIIA5071E

Page 4212 of 4462

SE-74
AUTOMATIC DRIVE POSITIONER
Revision: 2006 December 2006 FX35/FX45
3. CHECK TELESCOPIC SWITCH
ADP steering switch operate, check continuity between ADP steering switch connector M13 terminal 4, 5 and
1.
OK or NG
OK >> GO TO 4.
NG >> Replace ADP steering switch.
4. CHECK ADP STEERING SWITCH GROUND CIRCUIT
Check continuity between ADP steering switch connector M13 termi-
nal 1 and ground.
OK or NG
OK >> Check the condition of the harness and connector.
NG >> Replace or replace harness between ADP steering
switch and ground.
Connector Terminal ADP steering switch condition Continuity
M13 5
1 FORWARD Yes
Other than above No
4 BACKWARD Yes
Other than above No
PIIA4481E
1 (B) – Ground : Continuity should exist.
PIIA3308E

Page 4213 of 4462

AUTOMATIC DRIVE POSITIONER SE-75
C
D E
F
G H
J
K L
M A
B
SE
Revision: 2006 December 2006 FX35/FX45
Check Tilt Switch CircuitNIS001VR
1. CHECK FUNCTION
With CONSULT-II
With “TILT SW-UP, TILT SW-DOWN” on the DATA MONITOR, operate the ADP steering switch to check ON/
OFF operation.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Tilt switch operate, check voltage between automatic drive positioner control unit connector and ground.
OK or NG
OK >> Tilt switch circuit is OK.
NG >> GO TO 2.
2. CHECK TILT SWITCH CIRCUIT HARNESS CONTINUITY
1. Disconnect automatic drive positioner control unit connector and ADP steering switch connector.
2. Check continuity between automatic drive positioner control unit connector M49 terminals 1, 17 and ADP steering switch connec-
tor M13 terminals 2, 3.
3. Check continuity between automatic drive positioner control unit connector M49 terminals 1, 17 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between automatic drive positioner control unit and ADP steering
switch.
Monitor item
[OPERATION or UNIT] Contents
TILT SW-UP “ON/OFF” (ON/OFF) status judged from the tilt switch
(UP) signal is displayed.
TILT SW-DOWN “ON/OFF” (ON/OFF) status judged from the tilt switch
(DOWN) signal is displayed.
PIIA0315E
Connector Terminals
(Wire color) Tilt switch condition Voltage (V)
(Approx.)
(+) (–)
M49 1 (R)
Ground UP 0
Other than above 5
17 (R/B) DOWN 0
Other than above 5
PIIA5074E
1 (R) – 2 (R) : Continuity should exist.
17 (R/B) – 3 (R/B) : Continuity should exist.
1 (R) – Ground : Continuity should not exist.
17 (R/B) – Ground : Continuity should not exist.
PIIA5072E

Page 4214 of 4462

SE-76
AUTOMATIC DRIVE POSITIONER
Revision: 2006 December 2006 FX35/FX45
3. CHECK ADP TILT STEERING SWITCH
ADP steering switch operate, check continuity between ADP steering switch.
OK or NG
OK >> GO TO 6.
NG >> Replace ADP steering switch.
4. CHECK ADP STEERING SWITCH GROUND CIRCUIT
Check continuity between ADP steering switch connector M13 termi-
nal 1 and ground.
OK or NG
OK >> Check the condition of the harness and connector.
NG >> Repair or replace harness between ADP steering switch and ground.
Connector Terminal ADP steering switch condition Continuity
M13 2
1 UP Yes
Other than above No
3 DOWN Yes
Other than above No
PIIA4482E
1 (B) – Ground : Continuity should exist.
PIIA3310E

Page 4215 of 4462

AUTOMATIC DRIVE POSITIONER SE-77
C
D E
F
G H
J
K L
M A
B
SE
Revision: 2006 December 2006 FX35/FX45
Check Door Mirror Remote Control Switch (Changeover Switch) CircuitNIS001VS
1. CHECK FUNCTION
With CONSULT-II
Check the operation on “MIR CHNG SW-R” or “MIR CHNG SW-L” in the DATA MONITOR.
Without CONSULT-II
1. Turn ignition switch ACC.
2. Changeover switch operate, check voltage between automatic drive positioner control unit connector and ground.
OK
orNG
OK >> Door mirror remote control switch (changeover switch) circuit is OK.
NG >> GO TO 2.
2. CHECK CHANGEOVER SWITCH CIRCUIT HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect automatic drive positioner control unit and door mirror remote control switch connector.
3. Check continuity between automatic drive positioner control unit connector M49 terminal 2, 18 and door mirror remote control
switch connector M18 terminal 2, 3.
4. Check continuity between automatic drive positioner control unit connector M49 terminal 2, 18 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between automatic drive positioner control unit and door remote control switch.
Monitor item
[OPERATION or UNIT] Contents
MIR CHNG SW–R “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (switching to RIGHT) signal
is displayed.
MIR CHNG SW–L “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (switching to LEFT) signal
is displayed.
PIIA0191E
Connector Terminals (Wire color)
Changeover switch
condition Voltage (V)
(Approx.)
(+) (-)
M49 2 (G/W)
Ground RIGHT 0
Other than above 5
18 (L/OR) LEFT 0
Other than above 5
PIIA4767E
2 (G/W) – 3 (G/W) : Continuity should exist.
18 (L/OR) – 2 (L/OR) : Continuity should exist.
2 (G/W) – Ground : Continuity should not exist.
18 (L/OR) – Ground : Continuity should not exist.
PIIB3165E

Page 4216 of 4462

SE-78
AUTOMATIC DRIVE POSITIONER
Revision: 2006 December 2006 FX35/FX45
3. CHECK DOOR MIRROR REMOTE CONTROL SWITCH GROUND CIRCUIT
Check continuity between door mirror remote control switch connec-
tor M18 terminal 13 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK DOOR MIRROR REMOTE CONTROL SWITCH (CANGEOVER SWITCH)
Changeover switch operate, check continuity between door mirror remote control switch connector M18 termi-
nal 2, 3 and 13.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace door mirror remote control switch. 13 (B) – Ground : Continuity should exist.
PIIB3166E
Connector Terminal Changeover switch condition Continuity
M18 3
13 RIGHT Yes
Other than above No
2 LEFT Yes
Other than above No
PIIB3167E

Page 4217 of 4462

AUTOMATIC DRIVE POSITIONER SE-79
C
D E
F
G H
J
K L
M A
B
SE
Revision: 2006 December 2006 FX35/FX45
Check Door Mirror Remote Control Switch (Mirror Switch) CircuitNIS001VT
1. CHECK DOOR MIRROR REMOTE CONTROL SWITCH (MIRROR SWITCH) SIGNAL
With CONSULT-II
Check the operation on “MIR CON SW–UP/DN” and “MIR CON SW–RH/LH” in the DATA MONITOR.
Without CONSULT-II
1. Turn ignition switch ACC.
2. Mirror switch operate, check voltage between automatic drive positioner control unit connector and ground.
OK or NG
OK >> Door mirror remote control switch (mirror switch) circuit is OK.
NG >> GO TO 2.
Monitor item
[OPERATION or UNIT] Contents
MIR CON SW–UP “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (UP) signal is displayed.
MIR CON SW–DN “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (DOWN) signal is dis-
played.
MIR CON SW–RH “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (RIGHT) signal is dis-
played.
MIR CON SW–LH “ON/
OFF” ON/OFF status judged from the door mirror
remote control switch (LEFT) signal s displayed.
PIIA0199E
Connector Terminals (Wire color)
Mirror switch condition Voltage (V)
(Approx.)
(+) (-)
M49 3 (GY)
Ground UP 0
Other than above 5
4 (Y) LEFT 0
Other than above 5
19 (GY/L) DOWN 0
Other than above 5
20 (PU) RIGHT 0
Other than above 5
PIIA4771E

Page 4218 of 4462

SE-80
AUTOMATIC DRIVE POSITIONER
Revision: 2006 December 2006 FX35/FX45
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect automatic drive positioner control unit and door mirror remote control switch connector.
3. Check continuity between automatic drive positioner control unit connector M49 terminal 3, 4, 19, 20 and door mirror remote con-
trol switch connector M18 terminal 4, 5, 6, 14.
4. Check continuity between automatic drive positioner control unit connector M49 terminal 3, 4, 19, 20 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness between automatic drive positioner control unit and door mirror remote
control switch.
3. CHECK DOOR MIRROR REMOTE CONTROL SWITCH GROUND CIRCUIT
Check continuity between door mirror remote control switch connec-
tor M18 terminal 13 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK DOOR MIRROR REMOTE CONTROL SWITCH (MIRROR SWITCH)
Mirror switch operate, check continuity between door mirror remote control switch connector M18 terminal 4,
5, 6, 14 and 13.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace door mirror remote control switch. 3 (GY) – 6 (GY) : Continuity should exist.
4 (Y) – 5 (Y) : Continuity should exist.
19 (GY/L) – 14 (GY/L) : Continuity should exist.
20 (PU) – 4 (PU) : Continuity should exist.
3 (GY) – Ground : Continuity should not exist.
4 (Y) – Ground : Continuity should not exist.
19 (GY/L) – Ground : Continuity should not exist.
20 (PU) – Ground : Continuity should not exist.
PIIB3168E
13 (B) – Ground : Continuity should exist.
PIIB3166E
Connector Terminal Mirror switch condition Continuity
M18 4
13 RIGHT Yes
Other than above No
5 LEFT Yes
Other than above No
6 UP Yes
Other than above No
14 DOWN Yes
Other than above No
PIIB3169E

Page 4219 of 4462

AUTOMATIC DRIVE POSITIONER SE-81
C
D E
F
G H
J
K L
M A
B
SE
Revision: 2006 December 2006 FX35/FX45
Check Detention Switch (P Range Switch) CircuitNIS001VU
1. CHECK FUNCTION
With CONSULT-II
Make sure when the A/T selector lever is in P position, “P POSITION SW” on the DATA MONITOR becomes
ON.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between drive seat control unit connector and ground.
OK or NG
OK >> Detention switch circuit is OK.
NG >> GO TO 2.
2. CHECK DETENTION SWITCH POWER SUPPLY CIRCUIT HARNESS
1. Turn ignition switch OFF.
2. Disconnect driver seat control unit connector and A/T device (detention switch) connector.
3. Check continuity between driver seat control unit connector B152 terminal 17 and A/T device (detention switch) connector
M67 terminal 3.
4. Check continuity between driver seat control unit connector B152 terminal 17 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between driver seat control unit and A/T device (detention switch).
Monitor item
[OPERATION or UNIT] Contents
P POSITION SW “ON/
OFF” The selector lever position “P position (ON)/other than
P position (OFF)” judged from the detente switch sig-
nal is displayed.
PIIA6950E
Connector Terminals
(Wire color) Condition Voltage (V)
(Approx.)
(+) (–)
B152 17 (PU) Ground Selector lever sifted to P
position. 0
Selector lever other than P
position. Battery voltage
PIIA6702E
17 (PU) – 3 (R/Y) : Continuity should exist.
17 (PU) – Ground : Continuity should not exist.
PIIA6701E

Page 4220 of 4462

SE-82
AUTOMATIC DRIVE POSITIONER
Revision: 2006 December 2006 FX35/FX45
3. CHECK A/T DEVICE (DETENTION SWITCH)
Check continuity between A/T device (detection switch) connector
M67 terminal 2 and 3.
OK or NG
OK >> GO TO 4.
NG >> Replace A/T device (detention switch).
4. CHECK A/T DEVICE (DETENTION SWITCH) GROUND HARNESS
Check continuity between A/T device (detention switch) connector
M67 terminal 2 and ground.
OK or NG
OK >> Check the condition of the harness and connector.
NG >> Repair or replace harness between A/T device (deten-
tion switch) and ground.
Check Key Switch Circuit (With Intelligent Key)NIS001VV
1. CHECK KEY SWITCH POWER SUPPRY CIRCUIT (WITH CONSULT-II)
With CONSULT-II
Touch “BCM”. With “IGN KEY SW” on the DATA MONITOR, Check ON/OFF operation.
*: Refer to BL-37, "
Data Monitor" .
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2.
Connector Terminal Condition Continuity
M67 2 3 P position Yes
Other than P position No
PIIA6703E
2 (B) – Ground : Continuity should exist.
PIIA6704E
Monitor item [OPERA- TION or UNIT] Contents
IGN KEY SW
*“ON/
OFF” Key inserted (ON)/key removed (OFF) status judged
from the key-in detection switch is displayed.
PIIA0298E

Page:   < prev 1-10 ... 4171-4180 4181-4190 4191-4200 4201-4210 4211-4220 4221-4230 4231-4240 4241-4250 4251-4260 ... 4470 next >