brake light INFINITI QX4 2005 Factory Owner's Manual
Page 1761 of 3419
EC-570Revision: October 2005
DTC P1572 ASCD BRAKE SWITCH
2005 QX56
DTC confirmation ProcedureUBS00L16
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
Procedure for malfunction B is not described here. It takes extremely long time to complete procedure for
malfunction B. By performing procedure for malfunction A, the incident that causes malfunction B can be
detected.
TESTING CONDITION:
Steps 3 and 4 may be conducted with the drive wheels lifted in the shop or by driving the vehicle. If a
road test is expected to be easier, it is unnecessary to lift the vehicle.
WITH CONSULT-II
1. Start engine (VDC switch OFF).
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Press MAIN switch and make sure that CRUISE indicator lights
up.
4. Drive the vehicle for at least 5 consecutive seconds under the
following condition.
If DTC is detected, go to EC-572, "
Diagnostic Procedure" .
If DTC is not detected, go to the following step.
5. Drive the vehicle for at least 5 consecutive seconds under the
following condition.
6. If DTC is detected, go to EC-572, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
VHCL SPEED SE More than 30 km/h (19 MPH)
Selector lever Suitable position
VHCL SPEED SE More than 30 km/h (19 MPH)
Selector lever Suitable position
Driving locationDepress the brake pedal for more than
five seconds so as not to come off from
the above-mentioned condition.
PBIB2386E
Page 1763 of 3419
EC-572Revision: October 2005
DTC P1572 ASCD BRAKE SWITCH
2005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00L18
1. CHECK OVERALL FUNCTION-I
With CONSULT-II
1. Turn ignition switch ON.
2. Select “BRAKE SW1” in “DATA MONITOR” mode with CONSULT-II.
3. Check “BRAKE SW1” indication under the following conditions.
Without CONSULT-II
1. Turn ignition switch ON.
2. Check voltage between ECM terminal 108 and ground under the
following conditions.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
101 R/W Stop lamp switch[Ignition switch: OFF]
Brake pedal: Fully releasedApproximately 0V
[Ignition switch: OFF]
Brake pedal: Slightly depressedBATTERY VOLTAGE
(11 - 14V)
108 BR/W ASCD brake switch[Ignition switch: ON]
Brake pedal: Fully releasedBATTERY VOLTAGE
(11 - 14V)
[Ignition switch: ON]
Brake pedal: Slightly depressedApproximately 0V
CONDITION INDICATION
Brake pedal: Slightly depressed OFF
Brake pedal: Fully released ON
SEC0 11D
CONDITION VOLTAGE
Brake pedal: Slightly depressed Approximately 0V
Brake pedal: Fully released Battery voltage
MBIB0061E
Page 1764 of 3419
DTC P1572 ASCD BRAKE SWITCH
EC-573
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
2. CHECK OVERALL FUNCTION-II
With CONSULT-II
Check “BRAKE SW2” indication in “DATA MONITOR” mode.
Without CONSULT-II
Check voltage between ECM terminal 101 and ground under the following conditions.
OK or NG
OK >> GO TO 11.
NG >> GO TO 7.
CONDITION INDICATION
Brake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
SEC0 13 D
CONDITION VOLTAGE
Brake pedal: Fully released Approximately 0V
Brake pedal: Slightly depressed Battery voltage
PBIB1537E
Page 1767 of 3419
EC-576Revision: October 2005
DTC P1572 ASCD BRAKE SWITCH
2005 QX56
11 . CHECK INTERMITTENT INCIDENT
Refer to EC-156, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00L19
ASCD BRAKE SWITCH
1. Turn ignition switch OFF.
2. Disconnect ASCD brake switch harness connector.
3. Check harness continuity between ASCD brake switch terminals
1 and 2 under the following conditions.
If NG, adjust ASCD brake switch installation, refer to BR-6,
"BRAKE PEDAL" , and perform step 3 again.
STOP LAMP SWITCH
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch harness connector.
3. Check harness continuity between stop lamp switch terminals 1
and 2 under the following conditions.
If NG, adjust stop lamp switch installation, refer to BR-6,
"BRAKE PEDAL" , and perform step 3 again.
Condition Continuity
Brake pedal: Fully released Should exist.
Brake pedal: Slightly depressed Should not exist.
SEC0 23 D
Condition Continuity
Brake pedal: Fully released Should not exist.
Brake pedal: Slightly depressed Should exist.
PBIB2103E
Page 1777 of 3419
EC-586Revision: October 2005
DTC P1805 BRAKE SWITCH
2005 QX56
DTC P1805 BRAKE SWITCHPFP:25320
DescriptionUBS00HBX
Brake switch signal is applied to the ECM through the stop lamp switch when the brake pedal is depressed.
This signal is used mainly to decrease the engine speed when the vehicle is driving.
CONSULT-II Reference Value in Data Monitor ModeUBS00HBY
Specification data are reference values.
On Board Diagnosis LogicUBS00HBZ
The MIL will not light up for this diagnosis.
FAIL -S AFE M OD E
When the malfunction is detected, the ECM enters fail-safe mode.
DTC Confirmation ProcedureUBS00HC0
WITH CONSULT-II
1. Turn ignition switch ON.
2. Fully depress the brake pedal for at least 5 seconds.
3. Erase the DTC with CONSULT-II.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. If 1st trip DTC is detected, go to EC-588, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
MONITOR ITEM CONDITION SPECIFICATION
BRAKE SW
Ignition switch: ONBrake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1805
1805Brake switchA brake switch signal is not sent to ECM for an
extremely long time while the vehicle is driving.
Harness or connectors
(Stop lamp switch circuit is open or
shorted.)
Stop lamp switch
Engine operating condition in fail-safe mode
ECM controls the electric throttle control actuator by regulating the throttle opening to a small range.
Therefore, acceleration will be poor.
Vehicle condition Driving condition
When engine is idling Normal
When accelerating Poor acceleration
SEF 0 58 Y
Page 1779 of 3419
EC-588Revision: October 2005
DTC P1805 BRAKE SWITCH
2005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00HC2
1. CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Check the stop lamp when depressing and releasing the brake pedal.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
2. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Disconnect stop lamp switch harness connector.
2. Check voltage between stop lamp switch terminal 3 and ground
with CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
101 R/W Stop lamp switch[Ignition switch: OFF]
Brake pedal: Fully releasedApproximately 0V
[Ignition switch: OFF]
Brake pedal: Slightly depressedBATTERY VOLTAGE
(11 - 14V)
Brake pedal Stop lamp
Fully released Not illuminated
Slightly depressed Illuminated
BBIA0373E
Voltage: Battery voltage
PBIB2102E
Page 1781 of 3419
EC-590Revision: October 2005
DTC P1805 BRAKE SWITCH
2005 QX56
Component InspectionUBS00HC3
STOP LAMP SWITCH
1. Disconnect stop lamp switch harness connector.
2. Check continuity between stop lamp switch terminals 3 and 4
under the following conditions.
3. If NG, adjust stop lamp switch installation, refer to BR-6,
"BRAKE PEDAL" , and perform step 2 again.
BBIA0373E
Conditions Continuity
Brake pedal: Fully released Should not exist.
Brake pedal: Slightly depressed Should exist.
PBIB2103E
Page 1840 of 3419
ICC BRAKE SWITCH
EC-649
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
ICC BRAKE SWITCHPFP:25320
Component DescriptionUBS00L23
When depress on the brake pedal, ICC brake switch is turned OFF
and stop lamp switch is turned ON. ECM detects the state of the
brake pedal by this input of two kinds (ON/OFF signal)
Refer to ACS-6, "
DESCRIPTION" for the ICC function.
CONSULT-II Reference Value in Data Monitor ModeUBS00L24
Specification data are reference values.
BBIA0470E
MONITOR ITEM CONDITION SPECIFICATION
BRAKE SW 1
(ICC brake switch)
Ignition switch: ONBrake pedal: Fully released ON
Brake pedal: Slightly depressed OFF
BRAKE SW 2
(Stop lamp switch)
Ignition switch: ONBrake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
Page 1842 of 3419
ICC BRAKE SWITCH
EC-651
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00L26
1. CHECK OVERALL FUNCTION-I
With CONSULT-II
1. Turn ignition switch ON.
2. Select “BRAKE SW1” in “DATA MONITOR” mode with CON-
SULT-II.
3. Check “BRAKE SW1” indication under the following conditions.
Without CONSULT-II
1. Turn ignition switch ON.
2. Check voltage between ECM terminal 108 and ground under the
following conditions.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
101 R/W Stop lamp switch[Ignition switch: OFF]
Brake pedal: Fully releasedApproximately 0V
[Ignition switch: OFF]
Brake pedal: Slightly depressedBATTERY VOLTAGE
(11 - 14V)
108 BR/W ICC brake switch[Ignition switch: ON]
Brake pedal: Slightly depressedApproximately 0V
[Ignition switch: ON]
Brake pedal: Fully releasedBATTERY VOLTAGE
(11 - 14V)
CONDITION INDICATION
Brake pedal: Slightly depressed OFF
Brake pedal: Fully released ON
SEC0 11D
CONDITION VOLTAGE
Brake pedal: Slightly depressed Approximately 0V
Brake pedal: Fully released Battery voltage
MBIB0061E
Page 1843 of 3419
EC-652Revision: October 2005
ICC BRAKE SWITCH
2005 QX56
2. CHECK OVERALL FUNCTION-II
With CONSULT-II
Check “BRAKE SW2” indication in “DATA MONITOR” mode.
Without CONSULT-II
Check voltage between ECM terminal 101 and ground under the fol-
lowing conditions.
OK or NG
OK >>INSPECTION END
NG >> GO TO 10.
3. CHECK DTC WITH ICC UNIT
Refer to ACS-36, "
TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace.
CONDITION INDICATION
Brake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
SEC0 13 D
CONDITION VOLTAGE
Brake pedal: Fully released Approximately 0V
Brake pedal: Slightly depressed Battery voltage
PBIB1537E