JAGUAR X308 1998 2.G Workshop Manual
Page 1701 of 2490
W
ith relay 4 removed, check for battery voltage at relay
socket between pins 3 and 5.
1
B+
Yes GO to A5
No GO to A11
A5
: CHECK CIRCUIT CONTINUITY
•
NOTE: Do not replace relay.
Page 1702 of 2490
Measure t
he resistance between relay socket pin 5 and
ground BT020L.
1
I s
the resistance < 10OHM?
Yes GO to A6
No GO to A10
A6: CHECK FUEL
PUMP DRAWN CURRENT
•
NOTE
: With EM013 disconnected this test will cause the pump to operate continuously. Do not exceed 10 sec running.
•
NOTE: Do not replace relay.
Page 1703 of 2490
Wi
th the ignition energized, measure the current drawn
between relay socket pins 3 and 5.
1
Is
the current between 2.5 and 9 A?
Yes GO to A7
No GO to A10
A7
: CHECK B+ AT RELAY COIL
•
NOTE: Do not replace relay.
Page 1704 of 2490
Us
ing a link lead, connect EM013/001 to ground BT020L.
1
W
i
th ignition energized, check for battery voltage at relay
socket between pins 2 and 1.
2
B+?
Yes
GO t
o A10
No GO to A8
A8: CH
ECK RELAY COIL
CIRCUIT CONTINUITY
Page 1705 of 2490
W
ith EM013 disconnected, measure the resistance
between EM013/001 and relay socket pin 1.
1
I
s the resistance < 0.5 OHM?
Yes GO to A9
No Inspect harness / connec tors EM013, EM003/005,
FC001/42, BT004/019 and BT011/010 for corrosion,
damage, bent or pushed back pins. Repair as required
and test the system for normal operation.
A9: CHECK
ECM GROUND CONTINUITY
Page 1706 of 2490
Wi
th EM014 disconnected, measure the resistance
between EM014/010 and ground EM16L.
1
I s
the resistance < 0.5 OHM?
Yes STOP, renew the relay and test the system for normal
operation.
No Inspect harness / connector EM014, splice EMS37 and
ground EM16L for corrosion, damage, bent or pushed
back pins. Repair as requir ed and test the system for
normal operation.
A10: CHECK FU EL
PUMP CONTINUITY
Page 1707 of 2490
Wi
th BT009 disconnected, measure the resistance across
the fuel pump connectors reference BT009/001 and
BT009/002.
1
I
s the resistance < 5 OHM?
Yes GO to A11
No Renew the fuel pump and te st the system for normal
operation.
A11: CHECK FU
EL PUMP GROUND CONTINUITY
Page 1708 of 2490
With
BT009 disconnected, measure the resistance
between BT009/001 and ground BT020L.
1
I s
the resistance < 0.5 OHM?
Yes GO to A12
No Inspect harness / connector BT009, splice BTS021 and
ground BT020L for corrosion, damage, bent or pushed
back pins. Repair as requir ed and test the system for
normal operation.
A12
: CHECK CIRCUIT CONTINUITY
Page 1709 of 2490
Wi
th BT009 disconnected an
d relay 4 removed, measure
the resistance between BT009/002 and relay socket pin
5.
1
I
s the resistance < 0.5 OHM?
Yes GO to A13
No Inspect harness / connector BT 009, fuse holder F7 and
BT011/001 for corrosion, damage, bent or pushed back
pins. Repair as required and test the system for normal
operation.
A13: CHECK HARNESS SHO
RT TO GROUND
Page 1710 of 2490
Wi
th EM013 and BT009 disconnected, measure the
insulation resistance between EM013/001 and ground
BT020L.
1
Is
the resistance > 10M OHM?
Yes Do not replace relay or reconnect connectors.
GO to A14
No Inspect harness / connec tors EM013, EM003/005,
FC001/042, BT004/019 and BT011/010 for corrosion,
damage, bent or pushed back pins. Repair as required
and test the system for normal operation.
A1 4
: CHECK CORE TO CORE INSULATION