oil temperature LAND ROVER FREELANDER 2001 User Guide
Page 166 of 1007
MAINTENANCE
MAINTENANCE 10-19
Manual Gearbox – GETRAG
Replace Fluid
WARNING: Avoid excessive skin contact
with mineral oil. Mineral oils remove the
natural fats from the skin, leading to
dryness, irritation and dermatitis.
1.Replace gearbox fluid.
+ MANUAL GEARBOX - GETRAG,
ADJUSTMENTS, Gearbox oil - drain and
refill.
Automatic Gearbox – JATCO
Check and top-up fluid
WARNING: Avoid excessive skin contact
with mineral oil. Mineral oils remove the
natural fats from the skin, leading to
dryness, irritation and dermatitis.
1.Position vehicle on ramp.
2.Apply handbrake and position chocks under
front and rear wheels.
3.Remove underbelly panel.
+ EXTERIOR FITTINGS, REPAIRS,
Panel - underbelly.
4.Connect TestBook/T4 to monitor gearbox fluid
temperature.
CAUTION: The gearbox fluid level must only
be checked when the temperature of the
fluid is between 35° and 45°. The reading
obtained will be incorrect if the fluid is
outside this temperature range.
5.Start engine, move selector lever from 'P'
through all gear positions, pausing in each gear
position for 2-3 seconds and return to 'P'
position.
6.Clean area around level plug.
7.With the engine still running, remove level plug
using a 5 mm Allen socket and allow any
excess fluid to drain off.
CAUTION: There are a number of similar
fixings/plugs on the underside of the
gearbox. It is imperative that the correct
plug is removed prior to checking the level.
Removing the wrong fixing/plug could
result in internal damage to the gearbox.
8.If no fluid loss is apparent when level plug is
removed:
Page 167 of 1007
MAINTENANCE
10-20 MAINTENANCE
9.Remove filler plug and add fluid until it just runs
from level plug aperture.
When topping up after a new air blast cooler
(Td4 hot climates) has been fitted, an extra
420 cc of fluid is required. The fluid must
also reach a temperature of 80° C (176° F) to
allow the switch on the cooler to open.
10.Move selector lever from 'P' through each gear
position and return to 'P' , allowing any excess
fluid to drain off.
11.Fit new level plug and tighten to 14 Nm (10
lbf.ft).
12.Clean and fit filler plug.
13.Disconnect TestBook/T4.
14.Fit underbelly panel.
+ EXTERIOR FITTINGS, REPAIRS,
Panel - underbelly.
Rear Axle
Replace Fluid
1.With vehicle on a ramp at a convenient working
height, carefully remove rear differential level
plug.
2.Check oil level. Before topping up oil level,
check for visible signs of leakage. Pay
particular attention to drive shaft oil seals,
differential pinion oil seal and backplate
gasket.
3.Refit level plug to rear differential and tighten to
27 Nm (20 lbf.ft).
M44 1642
Page 178 of 1007
ENGINE - K SERIES KV6
ADJUSTMENTS 12-3-1
ENGIN E - K SERIES KV6 ADJUST ME NTS
Engine oil pressure check
$% 12.90.09.01
Check
1.Remove oil pressure switch.
+ ENGINE - K SERIES KV6, REPAIRS,
Switch - oil pressure.
2.Fit sealing washer from oil pressure switch to
LRT-12-052/10 oil pressure gauge adaptor.
3.Fit and tighten oil pressure gauge adaptor LRT-
12-052/10 to oil pump housing.
4.Connect oil pressure gauge LRT-12-052C and
tighten union.
5.Check and if necessary top up engine oil.
6.Start and run engine until normal operating
temperature is reached.
7.Note oil pressure readings with the engine
running at idle and at 3000 rev/min.
+ GENERAL DATA, Engine - KV6
Petrol.
8.Switch off engine, unscrew gauge union and
remove gauge.
9.Remove adaptor.
10.Wipe off oil spillage
11.Fit oil pressure switch.
+ ENGINE - K SERIES KV6, REPAIRS,
Switch - oil pressure.
12.Recheck engine oil and top up if necessary.
Page 405 of 1007
INTERMEDIATE REDUCTION DRIVE
41-2 ADJUSTMENTS
Intermediate reduction drive (IRD)
lubrication system - drain & refill - NAS
$% 41.25.06
Drain
1.Remove underbelly panel
+ EXTERIOR FITTINGS, REPAIRS,
Panel - underbelly.
2.Place container beneath IRD unit.
WARNING: Observe due care when draining
gearbox fluid as the fluid can be very hot.
3.Clean area around filler/level and drain plugs.
4.Using LRT-41-021 remove filler plug and
discard sealing washer.5.Remove drain plug, discard sealing washer and
allow oil to drain.
NOTE: The fluid should be drained with the
transmission at normal operating temperature.
6.Fit new sealing washer and tighten drain plug to
35 Nm (26 lbf.ft).
Refill
1.Fill with fluid until it just runs from filler/level
hole. Allow sufficient time for fluid to flow and
reach a common level in unit.
+ CAPACITIES, FLUIDS,
LUBRICANTS AND SEALANTS,
Lubrication.
2.Fit new sealing washer and tighten filler/level
plug to 35 Nm (26 lbf.ft).
3.Fit underbelly panel
+ EXTERIOR FITTINGS, REPAIRS,
Panel - underbelly.
M417853
LRT-41-021
M41 7687