sensor LEXUS LS430 2003 Factory Repair Manual

Page 267 of 4500

As the temperature increases, the voltage decreases.
Result:
AIR CONDITIONING AMPLIFIER (TE - SG) TEST RESULT
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
C: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
Fig. 49: Inspecting Air Conditioning Amplifier (TE
- SG)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
A: Go to next step
3.INSPECT A/C EVAPORATOR TEMPERATURE SENSOR
a. Remove the A/C evaporator temperature sensor.
b. Measure the resistance according to the value (s) in table below.
NGA
OK (Checking from the PROBLEM SYMPTOM TABLE)B
OK (Checking from the DTC)C

Page 268 of 4500

Standard:
A/C EVAPORATOR TEMPERATURE SENSOR RESISTANCE
<0029004c004a0011000300180013001d0003002c005100560053004800460057004c0051004a000300240012002600030028005900440053005200550044005700520055000300370048005000530048005500440057005800550048000300360048005100
5600520055[

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Tester connectionConditionSpecified condition
1 - 2-10°C (14°F)7.40 to 9.20 kohms
1 - 2-5°C (23°F)5.65 to 7.00 kohms
1 - 20°C (32°F)4.35 to 5.40 kohms
1 - 25°C (41°F)3.40 to 4.20 kohms
1 - 210°C (50°F)2.68 to 3.30 kohms
1 - 215°C (59°F)2.10 to 2.60 kohms
1 - 220°C (68°F)1.66 to 2.10 kohms
1 - 225°C (77°F)1.32 to 1.66 kohms
1 - 230°C (86°F)1.05 to 1.35 kohms

Page 269 of 4500

HINT:
As the temperature increases, the resistance decrease (see the graph below).
Fig. 51: Resistance/Temperature Graph

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
NG: REPLACE A/C EVAPORATOR TEMPERATURE SENSOR
HINT:
When replacing the evaporator temperature sensor, the attached sub-harness should be replaced along
with the sensor.
OK: Go to next step
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C
EVAPORATOR TEMPERATURE SENSOR) (SEE ELECTRONIC CIRCUIT INSPECTION
PROCEDURE )
a. Measure the resistance according to the value (s) in the table below.
Standard:
AIR CONDITIONING AMPLIFIER - A/C EVAPORATOR TEMPERATURE SENSOR

Page 271 of 4500

Fig. 53: Identifying Terminals Of A/C Evaporator Temperature Sensor Connector
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT
)
CIRCUIT DESCRIPTION
This sensor detects the register temperature and sends the appropriate signals to the A/C amplifier.
Fig. 54: DTC Detection Item Trouble Area Chart

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.

Page 272 of 4500

WIRING DIAGRAM
Fig. 55: Air Duct Sensor Circuit (Driver Side)

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
INSPECTION PROCEDURE
1.READ VALUE ON HAND-HELD TESTER
a. Connect the hand-held tester to the DLC3.
b. Turn the ignition switch to the ON position and push the hand-held tester main switch on.
c. Select the item below in the DATA LIST, and read the display on the hand-held tester.
DATA LIST / AIR CONDITIONER:
DATA LIST / AIR CONDITIONER
OK:
The display is as specified in the normal condition.
Result:
AIR CONDITIONER TEST RESULT
ItemMeasure Item/Display (Range)Normal ConditionDiagnostic
Note
DUCT
TEMP-DDuct sensor (Driver side) / min.: -12.7°C
(9.14°F) max.: 76.55°C (169.79°F)Actual duct temperature is
displayed (Driver side)-

Page 274 of 4500

Fig. 56: Inspecting Air Conditioning Amplifier (TFACEDR - SG-3)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Result:
AIR CONDITIONING AMPLIFIER (TFACEDR - SG-3) TEST RESULT
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
C: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
A: Go to next step
3.INSPECT AIR DUCT SENSOR
a. Remove the air duct sensor.
b. Measure the resistance according to the value (s) in the table below.
Standard:
NGA
OK (Checking from the PROBLEM SYMPTOM TABLE)B
OK (Checking from the DTC)C

Page 275 of 4500

AIR DUCT SENSOR RESISTANCE
HINT:
As the temperature increases, the resistance decreases.
Fig. 57: Inspecting Air Duct Sensor

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
NG: REPLACE AIR DUCT SENSOR
OK: Go to next step
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT
SENSOR) (SEE ELECTRONIC CIRCUIT INSPECTION PROCEDURE
)
a. Measure the resistance according to the value (s) in the table below.
Tester connectionConditionSpecified condition
D7-1 - D7-2at 0°C (32°F)14.5 to 19.0 kohms
D7-1 - D7-2at 25°C (77°F)4.8 to 5.2 kohms
D7-1 - D7-2at 50°C (122°F)1.6 to 2.0 kohms

Page 276 of 4500

Standard:
AIR CONDITIONING AMPLIFIER - AIR DUCT SENSOR RESISTANCE
Tester connectionConditionSpecified condition
A13-15 (TFACEDr) - D7-1AlwaysBelow 1 ohms
A13-10 (SG-3) - D7-2AlwaysBelow 1 ohms
A13-15 (TFACEDr) - Body groundAlways10 kohms or higher
A13-10 (SG-3) - Body groundAlways10 kohms or higher

Page 277 of 4500

Fig. 58: Checking Harness And Connector (Air Conditioning Amplifier - Air Duct Sensor)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.

Page 278 of 4500

NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
CIRCUIT DESCRIPTION
This sensor detects the register temperature and sends the appropriate signals to the A/C amplifier.
Fig. 59: DTC Detection Item Trouble Area Chart

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
WIRING DIAGRAM
Fig. 60: Air Duct Sensor Circuit (Passenger Side)

Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
INSPECTION PROCEDURE
1.READ VALUE ON HAND-HELD TESTER

Page:   < prev 1-10 ... 61-70 71-80 81-90 91-100 101-110 111-120 121-130 131-140 141-150 ... 690 next >