P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-301
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP canister pur ge volume control solenoid valve harness connector and
ECM harness connector.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 4.
YES-2 >> Without CONSULT: GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT. Check that engine speed varies according to the valve opening.
Does engine speed vary according to the valve opening?
YES >> GO TO 6.
NO >> GO TO 5.
5.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Refer to EC-301, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace EVAP canister purge volume control solenoid valve. Refer to FL-14, "
Removal and
Installation".
6.CHECK INTERMITTENT INCIDENT
Refer to GI-42, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000012431498
1.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Start engine.
5. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT.
EVAP canister purge volume
control solenoid valve ECM
Continuity
Connector Terminal Connector Terminal
F22 2F10 9 Existed
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1430 of 3641
P0447 EVAP CANISTER VENT CONTROL VALVEEC-303
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0447 EVAP CANISTER VENT CONTROL VALVE
DTC LogicINFOID:0000000012431499
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confi rm battery voltage is more than 11 V at idle.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and wait at least 8 seconds.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-303, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431500
1.INSPECTION START
Do you have CONSULT?
Do you have CONSULT?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
1. Turn ignition switch OFF and then turn ON.
2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
3. Touch “ON/OFF” on CONSULT screen.
4. Check for operating sound of the valve.
Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 3.
3.CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve harness connector.
3. Turn ignition switch ON.
DTC No. CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0447 VENT CONTROL VALVE
(EVAP canister vent control
valve circuit open) An improper voltage signal is sent to ECM
through EVAP canister vent control valve. • Harness or connectors
(EVAP canister vent control valve circuit is
open or shorted.)
• EVAP canister vent control valve
Clicking sound should be heard.
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1434 of 3641
P0448 EVAP CANISTER VENT CONTROL VALVEEC-307
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0448 EVAP CANISTER VENT CONTROL VALVE
DTC LogicINFOID:0000000012431502
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1. Turn ignition switch ON and wait at least 5 seconds.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode of “ENGINE” using CONSULT.
4. Start engine and let it idle for at least 1 minute.
5. Repeat next procedures three times.
- Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 min- utes.
Never exceed 3 minutes.
- Fully released accelerator pedal and keep engine idle for about 5 seconds.
6. Repeat next procedure 20 times.
- Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.
- Fully released accelerator pedal and keep engine idle for at least 35 seconds.
7. Check 1st trip DTC.
With GST
Follow the procedure “With CONSULT” above.
Is 1st trip DTC detected?
YES >> Proceed to EC-307, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431503
1.CHECK RUBBER TUBE
DTC No. CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0448 VENT CONTROL VALVE
(EVAP canister vent control
valve close) EVAP canister vent control valve
remains closed under specified
driving conditions. • EVAP canister vent control valve
• EVAP control system pressure sensor and the circuit
• Blocked rubber tube to EVAP canister vent control
valve
• EVAP canister is saturated with water
PBIB0972E
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1438 of 3641
P0451 EVAP CONTROL SYSTEM PRESSURE SENSOREC-311
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0451 EVAP CONTROL SYST
EM PRESSURE SENSOR
DTC LogicINFOID:0000000012431505
DTC DETECTION LOGIC
NOTE:
If DTC P0451 is displayed with DTC P0643, first pe rform the trouble diagnosis for DTC P0643. Refer to
EC-356, "
DTC Logic".
DTC CONFIRMATION PROCEDURE
NOTE:
Never remove fuel filler cap du ring DTC confirmation procedure.
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
With CONSULT>>GO TO 2.
Without CONSULT>>GO TO 5.
2.PERFORM DTC CONFIRMATION PROCEDURE-1
With CONSULT
1. Start engine and let it idle for least 40 seconds.
NOTE:
Do not depress accelerator pedal even slightly.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-312, "Diagnosis Procedure".
NO >> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE-2
With CONSULT
1. Select “EVAP DIAG READY” in “DATA MONITOR” mode of “ENGINE”.
2. Let it idle until “OFF” of “EVAP DIAG READY” changes to “ON”.
NOTE:
It will take at most 2 hours until “OFF” of “EVAP DIAG READY ” changes to “ON”.
3. Turn ignition switch OFF and wait at least 90 minutes.
NOTE:
Never turn ignition swit ch ON during 90 minutes.
4. Turn ignition switch ON.
5. Select “EVAP LEAK DIAG” in “DATA MONITOR” mode of “ENGINE”.
6. Check that “EVAP LEAK DIAG” indication.
Which is displayed on CONSULT?
CMPLT >> GO TO 4.
YET >> 1. Perform DTC CONF IRMATION PROCEDURE again.
2. GO TO 1.
4.PERFORM DTC CONFIRMATION PROCEDURE-3
DTC No. CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0451 EVAP SYS PRES SEN
(EVAP control system pressure
sensor performance) ECM detects a sloshing signal from
the EVAP control system pressure
sensor • Harness or connectors
(EVAP control system pressure sensor circuit is
shorted.)
• EVAP control system pressure sensor
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1439 of 3641
EC-312
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
With CONSULT
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-312, "Diagnosis Procedure".
NO >> INSPECTION END
5.PERFORM DTC CONFIRMATION PROCEDURE-4
With GST
1. Start engine and let it idle for least 40 seconds.
NOTE:
Do not depress accelerator pedal even slightly.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-312, "Diagnosis Procedure".
NO >> GO TO 6.
6.PERFORM DTC CONFIRMATION PROCEDURE-5
With GST
1. Let it idle for at least 2 hours.
2. Turn ignition switch OFF and wait at least 90 minutes. NOTE:
Never turn ignition switch ON during 90 minutes.
3. Turn ignition switch ON.
4. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-312, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431506
1.CHECK EVAP CONTROL SYSTEM PRESS URE SENSOR CONNECTOR FOR WATER
1. Turn ignition switch OFF.
2. Disconnect EVAP control system pressure sensor harness connector.
3. Check sensor harness connector for water.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace harness connector.
2.CHECK EVAP CONTROL SYSTEM PR ESSURE SENSOR POWER SUPPLY
1. Turn ignition switch ON.
2. Check the voltage between EVAP control syst em pressure sensor harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK EVAP CONTROL SY STEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector.
Water should not exist.
EVAP control system pressure sensor GroundVo l ta g e
(Approx.)
Connector Terminal
B3 3Ground 5 V
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1442 of 3641
P0452 EVAP CONTROL SYSTEM PRESSURE SENSOREC-315
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0452 EVAP CONTROL SYST
EM PRESSURE SENSOR
DTC LogicINFOID:0000000012431508
DTC DETECTION LOGIC
NOTE:
If DTC P0451 is displayed with DTC P0643, first pe rform the trouble diagnosis for DTC P0643. Refer to
EC-356, "
DTC Logic".
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41° F) or more.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode of “ENGINE” using CONSULT.
5. Make sure that “FUEL T/TMP SE” indication is more than 0 °C (32 °F).
6. Start engine and wait at least 20 seconds.
7. Check 1st trip DTC.
With GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes to ECM harness connector terminals as per the following.
3. Make sure that the voltage is less than 4.2 V.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Start engine and wait at least 20 seconds.
6. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-315, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431509
1.CHECK EVAP CONTROL SYS TEM PRESSURE SENSOR CONNECTOR FOR WATER
DTC No.CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0452 EVAP SYS PRES SEN
(EVAP control system pressure
sensor low input) An excessively low voltage from the sensor
is sent to ECM. • Harness or connectors
(EVAP control system pressure sensor
circuit is shorted.)
• EVAP control system pressure sensor
ECM
Vo l ta g e
Connector +
−
Te r m i n a l
F11 4368 Less than 4.2 V
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1445 of 3641
EC-318
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
DTC LogicINFOID:0000000012431511
DTC DETECTION LOGIC
NOTE:
If DTC P0451 is displayed with DTC P0643, first pe
rform the trouble diagnosis for DTC P0643. Refer to
EC-356, "
DTC Logic".
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode of “ENGINE” using CONSULT.
5. Make sure that “FUEL T/TMP SE” indication is more than 0 °C (32° F).
6. Start engine and wait at least 20 seconds.
7. Check 1st trip DTC.
With GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes to ECM harness connector terminals as per the following.
3. Make sure that the voltage is less than 4.2 V.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Start engine and wait at least 20 seconds.
6. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-318, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431512
1.CHECK EVAP CONTROL SYSTEM PRESS URE SENSOR CONNECTOR FOR WATER
DTC No.CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0453 EVAP SYS PRES SEN
(EVAP control system pressure
sensor high input) An excessively high voltage from the sensor
is sent to ECM. • Harness or connectors
(EVAP control system pressure sensor
circuit is shorted.)
• EVAP control system pressure sensor
ECM
Vo l ta g e
Connector +
−
Terminal
F11 43 68Less than 4.2 V
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1450 of 3641
P0456 EVAP CONTROL SYSTEMEC-323
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
Do you have CONSULT?
YES >> GO TO 2.
NO >> GO TO 4.
2.PERFORM DTC CONFIRMATION PROCEDURE-I
WITH CONSULT
1. Turn ignition switch ON and select “EVAP DIAG RE ADY” in “DATA MONITOR” mode of “ENGINE” using
CONSULT.
2. Start engine and wait at idle until “OFF” of “EVAP DIAG READY” changes to “ON”. NOTE:
It will take at most 2 hours until “OFF” of “EVAP DIAG READY ” changes to “ON”.
3. Turn ignition switch OFF and wait at least 90 minutes. NOTE:
Never turn ignition swit ch ON during 90 minutes.
4. Turn ignition switch ON and select “EVAP LEAK DIAG” in “DATA MONITOR” mode of “ENGINE” using CONSULT.
5. Check that “EVAP LEAK DIAG” indication.
Which is displayed on CONSULT?
CMPLT >> GO TO 3.
YET >> Perform DTC CONFIRMATION PROCEDURE again. GO TO 1.
3.PERFORM DTC CONFIRMATION PROCEDURE-II
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-323, "Diagnosis Procedure".
NO >> INSPECTION END.
4.PERFORM DTC CONFIRMATION PROCEDURE
WITH GST
1. Start engine and wait engine idle for at least 2 hours.
2. Turn ignition switch OFF and wait at least 90 minutes. NOTE:
Never turn ignition swit ch ON during 90 minutes.
3. Turn ignition switch ON.
4. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-323, "Diagnosis Procedure".
NO >> INSPECTION END.
Diagnosis ProcedureINFOID:0000000012431515
1.CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1452 of 3641
P0456 EVAP CONTROL SYSTEMEC-325
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1. Remove EVAP canister (1) wit
h EVAP canister vent control
valve (2) and EVAP control syst em pressure sensor attached.
2. Check if water will drain from the EVAP canister.
Does water drain from EVAP canister?
YES >> GO TO 8.
NO-1 >> With CONSULT: GO TO 10.
NO-2 >> Without CONSULT: GO TO 11.
8.CHECK EVAP CANISTER
Weigh the EVAP canister assembly with the EVAP canist er vent control valve and EVAP control system pres-
sure sensor attached. Refer to FL-17, "
Removal and Installation".
The weight should be less than 1.6 kg (3.5 lb).
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 10.
YES-2 >> Without CONSULT: GO TO 11.
NO >> GO TO 9.
9.DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehi cle frame for clogging or poor connection
>> Repair hose or replace EVAP canister. Refer to FL-14, "
Removal and Installation".
10.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT
1. Disconnect vacuum hose to EVAP canister purge volu me control solenoid valve at EVAP service port.
2. Start engine and let it idle.
3. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
4. Touch “Qu” on CONSULT screen to in crease “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum.
Is the inspection result normal?
YES >> GO TO 13.
NO >> GO TO 12.
11 .CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volu me control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
Is the inspection result normal?
YES >> GO TO 13.
NO >> GO TO 12.
12.CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to FL-14, "
Exploded View".
Is the inspection result normal?
PBIB2731E
Vacuum should exist.
Vacuum should exist.
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1455 of 3641
EC-328
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0460 FUEL LEVEL SENSOR
P0460 FUEL LEVEL SENSOR
DTC LogicINFOID:0000000012431517
DTC DETECTION LOGIC
NOTE:
•
If DTC P0460 is displayed with DTC UXXXX, first perform the trouble diagnosis for DTC UXXXX.
• If DTC P0460 is displayed with DTC P0607, first perform the trouble diagno sis for DTC P0607. Refer
to EC-353, "
DTC Logic".
When the vehicle is parked, naturally the fuel level in the fuel tank is stable. It means that output signal of the
fuel level sensor does not change. If ECM senses sloshi ng signal from the sensor, fuel level sensor malfunc-
tion is detected.
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and wait maximum of 2 consecutive minutes.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-328, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431518
1.CHECK COMBINATION METER FUNCTION
Refer to MWI-18, "
CONSULT Function (METER/M&A)".
Is the inspection result normal?
YES >> CHECK INTERMITTENT INCIDENT. Refer to GI-42, "Intermittent Incident".
NO >> Refer to MWI-45, "
Component Function Check".
DTC No.CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0460 FUEL LEV SEN SLOSH (Fuel level sensor circuit noise) Even though the vehicle is parked, a
signal being varied is sent from the
fuel level sensor to ECM. • Harness or connectors
(The CAN communication line is open or shorted)
• Harness or connectors (The sensor circuit is open or shorted)
• Combination meter
• Fuel level sensor
Revision: August 2015 2016 Versa Note