Unified NISSAN TEANA 2003 Owners Manual
Page 1240 of 3502
DI-34
UNIFIED METER AND A/C AMP
8. CHECK VOLTAGE SIGNAL OF UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF and connect unified meter and A/C amp. connector.
2. Turn ignition switch ON.
3. Check voltage signal between combination meter harness con-
nector M70 terminal 19 and ground.
OK or NG
OK >> Replace combination meter.
NG >> Replace unified meter and A/C amp. Refer to DI-34, "
Removal and Installation of Unified Meter
and A/C Amp." .
DTC [B2205] Vehicle Speed CircuitBKS002B3
1. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) SELF-DIAGNOSIS
Perform the ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-57, "
CONSULT-II Func-
tions" (with VDC system) or BRC-17, "CONSULT-II Functions (ABS)" (without VDC system).
Self
-diagnostic results content
No malfunction detected>>Replace unified meter and A/C amp.
Malfunction detected>>Check applicable parts, and repair or replace corresponding parts.
Removal and Installation of Unified Meter and A/C Amp.BKS001SP
REMOVAL
1. Remove the audio unit. Refer to AV- 1 5 , "Removal and Installa-
tion of Audio Unit" (with integrated display system) or AV- 3 4 ,
"Removal and Installation of Audio Unit" (with integrated color
display system).
2. Remove screws (5) and remove bracket.
3. Remove screw and remove the unified meter and A/C amp.
(Auto amp.)
INSTALLATION
Note the following, and install in the reverse order of removal.
CAUTION:
Unified meter and A/C amp. screws (2) are different from other securing screws. Never confuse them
when installing.19 – Ground:
SKIA8732E
SKIA3362E
SKIA8643E
Page 1241 of 3502
WARNING LAMPS
DI-35
C
D
E
F
G
H
I
J
L
MA
B
DI
WARNING LAMPSPFP:24814
System DescriptionBKS003R5
OIL PRESSURE WARNING LAMP
Oil pressure warning lamp turns ON when reducing engine oil pressure abnormally.
IPDM E/R inputs oil pressure switch signal from oil pressure switch, and transmits the signal to unified
meter and A/C amp. through BCM with CAN communication.
Unified meter and A/C amp. transmits oil pressure switch signal to combination meter with communication
line.
Let the combination meter turn oil pressure warning lamp ON with received oil pressure switch signal.
Page 1251 of 3502
WARNING LAMPS
DI-45
C
D
E
F
G
H
I
J
L
MA
B
DI
Oil Pressure Warning Lamp Stays Off (Ignition Switch ON)BKS001SS
1. CHECK IPDM E/R OUTPUT SIGNAL
Activate IPDM E/R auto active test. Refer to PG-21, "
Auto Active Test" .
Is oil pressure warning lamp blinking?
No malfunction detected>> GO TO 5.
Malfunction detected>> Go to 2.
2. CHECK SELF-DIAGNOSTIC RESULTS OF IPDM E/R
Select “IPDM E/R” on CONSULT-II, and perform self diagnosis of IPDM E/R. Refer to PG-19, "
CONSULT-II
Function (IPDM E/R)"
Self-diagnosis result content?
YES >> GO TO 3.
NO >> GO TO PG-19, "
SELF-DIAG RESULTS" in “IPDM E/R”.
3. CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
Select “METER A/C AMP” on CONSULT-II. Operate ignition switch
with “OIL W/L” of “DATA MONITOR” and check operation status.
OK or NG
OK >> Replace combination meter.
NG >> GO TO 4.
4. CHECK BCM INPUT SIGNAL
Select “DATA MONITOR” of “SIGNAL BUFFER”. Refer to BCS-13,
"CONSULT-II Function (BCM)" . Operate ignition switch with “OIL
PRESS SW” of “DATA MONITOR” and check operate status.
OK or NG
OK >> Replace combination meter .
NG >> Replace IPDM E/R.“OIL W/L”
When ignition switch is in ON
position (Engine stopped.): ON
When engine running : OFF
PKIA2064E
“OIL PRESS SW”
When ignition switch is in ON
position (Engine stopped.): ON
When engine running : OFF
SKIA8709E
Page 1256 of 3502
DI-50
A/T INDICATOR
A/T Indicator Is MalfunctionBKS001SW
1. CHECK SELF-DIAGNOSIS OF COMBINATION METER
Perform combination meter self-diagnosis. Refer to DI-13, "
OPERA-
TION PROCEDURE"
Are all segments displayed?
YES >> GO TO 2.
NO >> Replace combination meter.
2. CHECK SELF-DIAGNOSIS RESULTS OF UNIFIED AND METER AND A/C AMP.
Select “METER A/C AMP” on CONSULT-II, and then perform self-diagnosis of unified meter and A/C amp.
Refer to DI-29, "
CONSULT-II Function (METER A/C AMP)"
Self-diagnosis result content
No malfunction detected >>SO TO 3
Malfunction detected >>GO TO DI-17, "
SYMPTOM CHART 2"
3. CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
1. Connect CONSULT-II and start engine.
2. Use “DATA MONITOR” of “METER A/C AMP” on CONSULT-II.
Confirm each indication on the monitor when operating the shift
lever.
OK or NG
OK >> Replace combination meter.
NG >> GO TO 4.
SKIB0783E
CONSULT-II display Switch operation Operation status
P RANGE INDP range position ON
Except for P range position OFF
R RANGE INDR range position ON
Except for R range position OFF
N RANGE INDN range position ON
Except for N range position OFF
D RANGE INDD range position ON
Except for D range position OFF
3 RANGE IND3 range position ON
Except for 3 range position OFF
2 RANGE IND2 range position ON
Except for 2 range position OFF
1 RANGE IND1 range position ON
Except for 1 range position OFF
SKIB0784E
Page 1260 of 3502
DI-54
CVT INDICATOR
CVT Indicator Is MalfunctionBKS002B6
1. CHECK SELF-DIAGNOSIS OF COMBINATION METER
Perform combination meter self-diagnosis. Refer to DI-13, "
OPERA-
TION PROCEDURE" .
Are all segments displayed?
YES >> GO TO 2.
NO >> Replace combination meter.
2. CHECK SELF-DIAGNOSTIC RESULTS OF UNIFIED METER AND A/C AMP.
Select “METER A/C AMP” on CONSULT-II, and perform self-diagnosis of unified meter and A/C amp. Refer
toDI-29, "
CONSULT-II Function (METER A/C AMP)" .
Self
-diagnostic results content
No malfunction detected>>GO TO 3.
Malfunction detected>>Check applicable parts, and repair or replace corresponding parts.
3. CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
1. Connect CONSULT-II and start engine.
2. Use “DATA MONITOR” of “METER A/C AMP” on CONSULT-II.
Confirm each indication on the monitor when operating the shift
lever.
OK or NG
OK >> Replace combination meter.
NG >> GO TO 4.
EL-3828D
CONSULT-II display Switch operationOperation
status
AT - M I N DManual mode range ON
Except for manual mode range OFF
AT - M G E A RManual mode range (shift-up or down) 5-1
Except for manual mode range 1
P RANGE INDP range position ON
Except for P range position OFF
R RANGE INDR range position ON
Except for R range position OFF
N RANGE INDN range position ON
Except for N range position OFF
D RANGE INDD range position ON
Except for D range position OFF
L RANGE INDL range position ON
Except for L range position OFF
PKID0249E
Page 1262 of 3502
DI-56
WARNING CHIME
WARNING CHIMEPFP:24814
System DescriptionBKS001SX
POWER SUPPLY AND GROUND CIRCUIT
Power is supplied at all times
through 50A fusible link (letter M , located in the fuse and fusible link block)
to BCM terminal 55,
through 15A fuse [No. 17, located in the fuse block (J/B)]
to combination meter terminal 7
to key switch terminal 1 (without Intelligent Key), and
to BCM terminal 42,
through 15A fuse [No. 18, located in the fuse block (J/B)] (with Intelligent Key)
to key switch terminal 3, and
to ignition knob switch terminal 7,
through 10A fuse [No. 19, located in the fuse block (J/B)]
to unified meter and A/C amp. terminal 21.
When ignition switch ON or START position, power is supplied
through 10A fuse [No. 1, located in the fuse block (J/B)]
to BCM terminal 38,
through 10A fuse [No. 12, located in the fuse block (J/B)]
to unified meter and A/C amp. terminal 22,
through 10A fuse [No. 14, located in the fuse block (J/B)]
to combination meter terminal 8.
Ground is supplied
to BCM terminal 52
to unified meter and A/C amp. terminals 29 and 30, and
to combination meter terminals 10, 11 and 12
through grounds M71 and M72.
NOTE:
When ignition key warning chime and light warning chime should be performed at the same time, the priorities
for each chime are the following.
1. Light warning chime
2. Ignition key warning chime
IGNITION KEY WARNING CHIME (WITHOUT INTELLIGENT KEY)
With the key inserted into the ignition switch, and the ignition switch OFF or ACC, when driver's door open, the
warning chime will sound.
Power is supplied
through key switch terminal 4
to BCM terminal 37.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects key inserted into the ignition switch, and sends key warning signal to unified meter and A/C amp.
with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination meter
with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
Page 1263 of 3502
WARNING CHIME
DI-57
C
D
E
F
G
H
I
J
L
MA
B
DI
IGNITION KEY WARNING CHIME (WITH INTELLIGENT KEY)
When Mechanical Key Is Used
With the key inserted into the ignition switch, and the ignition switch LOCK or ACC, when driver's door open,
the warning chime will sound.
Power is supplied
through ignition knob switch, key switch and key lock solenoid terminal 8
to BCM terminal 37.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects key inserted into the ignition switch, and sends key warning signal to unified meter and A/C amp.
with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination meter
with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
When Intelligent Key Is Carried With The Driver
With the ignition knob is in LOCK (push switch ON) or ACC, when driver's door open, the warning chime will
sound.
Power is supplied
through ignition knob switch, key switch and key lock solenoid terminal 2
to Intelligent Key unit terminal 27.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM sends front door switch signal to Intelligent Key unit with CAN communication line.
Intelligent Key unit detects ignition knob return is forgotten, and sends key warning signal to unified meter and
A/C amp. with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination
meter with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
LIGHT WARNING CHIME
With the key removed from the ignition switch or with the ignition knob is in LOCK (push switch OFF) [with
Intelligent Key], the drive door open, and the lighting switch in ON position, the warning chime will sound.
[Except when headlamp battery saver control operates (for 5 minutes after ignition switch is turned to OFF or
ACC position) and headlamps do not illuminate.]
Signal is supplied
from combination switch (lighting switch) terminals 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10
to BCM terminals 2, 3, 4, 5, 6, 32, 33, 34, 35 and 36.
NOTE:
BCM detected lighting switch in 1st or 2nd position, refer to LT- 1 8 3 , "
Combination Switch Reading Func-
tion" .
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects headlamps are illuminated, and sends light warning signal to unified meter and A/C amp. with
CAN communication line. Unified meter and A/C amp. sends light warning signal to combination meter with
communication line between unified meter and A/C amp. and combination meter.
When combination meter receives light warning signal, it sounds warning chime.
Page 1270 of 3502
DI-64
WARNING CHIME
*1: With Intelligent key
*2: Without Intelligent key
Terminals and Reference Value for Unified Meter and A/C Amp. BKS001T4
35 G/B Combination switch output 2
ONLights, turn signals, wipers OFF
(Wiper dial position 4)
36 G/W Combination switch output 1
37B/R
*1
BR*2Key switch signal OFFKey is removed Approx. 0V
Key is inserted Approx. 12V
38 R Ignition switch ON or START ON — Battery voltage
39 L CAN-H OFF — —
40 P CAN-L OFF — —
42 Y/R Battery power supply OFF — Battery voltage
52 B Ground ON — Approx. 0V
55 W/B Battery power supply OFF — Battery voltage
62 SB Front door switch (driver side) OFFWhen driver door is opened
(Door switch ON)Approx. 0V
When driver door is closed
(Door switch OFF)Approx. 12V Te r m i n a lWire
colorItemMeasuring condition
Reference value
Ignition
switchOperation or condition
SKIA5292E
Te r m i n a lWire
colorItem Measuring condition
Reference value
Ignition
switchOperation or condition
1 L CAN-H OFF — —
9RTX communication line (To
combination meter)ON —
11 P C A N - L O F F — —
19 G/BRX communication line
(From combination meter)ON —
21 Y/R Battery power supply OFF — Battery voltage
22 G Ignition switch ON or START ON — Battery voltage
29 B Ground (power) ON — Approx. 0V
30 B Ground ON — Approx. 0V
SKIA3362E
SKIA3361E
Page 1271 of 3502
WARNING CHIME
DI-65
C
D
E
F
G
H
I
J
L
MA
B
DI
Terminals and Reference Value for Combination MeterBKS001T5
CONSULT-II FunctionBKS001T6
CONSULT-II performs the following functions communicating with the BCM.
DIAGNOSTIC ITEMS DESCRIPTION
CONSULT-II BASIC OPERATION PROCEDURE
Refer to GI-34, "CONSULT-II Start Procedure" .
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which performs CAN communication.
DATA MONITOR
Operation procedure
1. Touch “BUZZER” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch “ALL SIGNALS” or “SELECTION FROM MENU” on “DATA MONITOR” screen.
4. If “SELECTION FROM MENU” is selected, touch the desired monitor item. If “ALL SIGNALS” is selected,
all items required to control are monitored.
5. Touch “START”.
6. During monitoring, touching “RECORD” can start recording the monitored item status.
TerminalWire
colorItem Measuring condition
Reference value
Ignition
switchOperation or condition
7 Y/R Battery power supply OFF — Battery voltage
8 P Ignition switch ON or START ON — Battery voltage
10
B Ground ON — Approx. 0V 11
12
18 G/BTX communication line (To
unified meter and A/C amp.)ON —
19 RRX communication line
(From unified meter and A/C
amp.)ON —
SKIA3361E
SKIA3362E
System Test Item Diagnosis mode Description
BCM BUZZERData monitor The input data to the BCM control unit is displayed in real time.
Active test Operation of electrical loads can be checked by sending driving signal to them.
ALL SIGNALS Monitors main items.
SELECTION FROM MENU Selects and monitors items.
Page 1272 of 3502
DI-66
WARNING CHIME
Display Item List
ACTIVE TEST
Operation procedure
1. Touch “BUZZER” on “SELECT TEST ITEM” screen.
2. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch the item to be tested, and check the operation.
4. During the operation check, touching “OFF” deactivates the operation.
Display Item LIst
Trouble DiagnosisBKS001T7
HOW TO PROCEED WITH TROUBLE DIAGNOSIS
1. Confirm the malfunction symptom or customer complaint.
2. Understand the outline of system. Refer to DI-56, "
System Description" .
3. Perform preliminary check. Refer to DI-66, "
PRELIMINARY CHECK" .
4. Select “METER A/C AMP” on CONSULT-II, and then perform self-diagnosis of unified meter and A/C
amp. Refer to DI-29, "
CONSULT-II Function (METER A/C AMP)" . When no malfunction detected, go to
next step 5. When malfunction detected, go to DI-17, "
SYMPTOM CHART 2" in “COMBINATION
METER”.
5. Check symptom and repair or replace the cause of malfunction.
6. Does the warning chime operate normally? If so, GO TO 7. If not, GO TO 5.
7. INSPECTION END
PRELIMINARY CHECK
1. CHECK FUSE AND FUSIBLE LINK
Check BCM fuses and fusible link for blown-out.
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse
or fusible link. Refer to PG-3, "
POWER SUPPLY ROUTING CIRCUIT" .
Monitor item [Unit] ALL SIGNALSSELECTION
FROM MENUDescription
IGN ON SW [ON/OFF] X X Indicates [ON/OFF] condition of ignition switch.
KEY ON SW [ON/OFF] X X Indicates [ON/OFF] condition of key switch.
DOOR SW-DR [ON/OFF] X X Indicates [ON/OFF] condition of front door switch (driver side).
LIGHT SW 1ST [ON/OFF] X X Indicates [ON/OFF] condition of lighting switch.
FR FOG SW [ON/OFF] X X Indicates [ON/OFF] condition of front fog lamp switch.
Test item Malfunction is detected when···
IGN KEY WARN ALMThis test is able to check key warning chime operation. Key warning chime sounds for 2 seconds
after touching “ON” on CONSULT-ll screen.
LIGHT WARN ALMThis test is able to check light warning chime operation. Light warning chime sounds for 2 seconds
after touching “ON” on CONSULT-ll screen.
Unit Power source Fuse and fusible link No.
BCMBatteryM
17
Ignition switch ON or START 1