RENAULT SCENIC 2007 J84 / 2.G Automatic Transmission Siemens TA2005 Service Manual

Page 41 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-41V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF109
PRESENT
OR
STOREDENGINE TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF109/DP0TA2005_V18_DF109

Page 42 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-42V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF112
PRESENT
OR
STOREDEVS6 SEQUENCE SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESDeal with fault DF012 Solenoid valves supply first if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5AU, between components 119 and 754,
●connection code 5DM, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5DM,
●connection code 5AU.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 40 Ω ± 2
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF112/DP0TA2005_V18_DF112

Page 43 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-43V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF113
PRESENT
OR
STOREDCONVERTER LOCK-UP SERVO CONTROL
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF177 Automatic transmission overheating.
–DF226 Automatic transmission internal pressure.
–DF244 Turbine speed sensor signal
Use the Mégane II or Scénic II wiring diagram Technical Note.
Check the quality and level of the gearbox oil (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the gearbox is not leaking oil.
Carry out the converter setting point test.
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
Warm engine with gearbox oil temperature between 65 and 90˚C.
Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF113/DP0TA2005_V18_DF113

Page 44 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-44V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF113
CONTINUED
If the line pressure recorded under one of these 3 conditions is incorrect, replace the line pressure sensor.
If the line pressures recorded under these 3 conditions are good, then the pressure sensor is operating correctly.
Replace the pressure regulating solenoid valve.
If the fault is still present after the pressure regulating solenoid valve has been replaced, replace the hydraulic
distributor and during refitting, take into account Technical Note 4194A Automatic transmission indicator strip
flashing for the adjustment of the ball detent blade
If the fault is still present, contact the Techline
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.

Page 45 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-45V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF131
PRESENT
OR
STOREDSLIPPAGE
1.DEF: Permanent low level
NOTESDeal with all other faults first.
Conditions for applying the fault finding procedure to stored faults:
Safe mode is triggered after a fault, not by the driver.
In particular, check that there are no faults on:
–the turbine speed sensor, DF244 Turbine speed sensor signal.
–the vehicle speed signal, DF230 Invalid vehicle speed multiplex signal.
Check that PR003 “Oil pressure” equals 21 bar. (forced setpoint)
Possible defective components:
Slave cylinder (brakes, clutch) or computer.
Then check cleanliness and condition of the gearbox oil.
If the fault is still present, contact Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF131/DP0TA2005_V18_DF131

Page 46 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-46V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
If the fault appears following a road test during which the quality of the gear changes
deteriorates.
Disconnect the battery.
Disconnect the gearbox computer. Check the cleanliness and condition of the connectors.
Disconnect the engine management computer. Check the cleanliness and condition of the connectors.
If the fault is still present, run fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
Repair if necessary.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF145/DP0TA2005_V18_DF145

Page 47 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-47V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF147
PRESENT
OR
STOREDINVALID ANTICIPATED TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF147/DP0TA2005_V18_DF147

Page 48 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-48V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF017 Exchanger flow solenoid valve circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF131 Slipping.
–DF226 Automatic transmission internal pressure.
–DF237 Invalid coolant temperature signal.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the water-oil exchanger is not blocked.
Measure the resistance of component 754 between the following connections:
●connection code 5BC,
●connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be between:
2660 Ω < R < 2360 Ω at 20˚C and 327 Ω < R < 290 Ω at 80˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF177/DP0TA2005_V18_DF177

Page 49 of 139

Fault finding - Interpretation of faults23A
23A-49V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
DF183
PRESENT
OR
STOREDNO UCH MULTIPLEX SIGNAL
1.DEF: Carry out the multiplex network fault finding procedure
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, run fault finding on the UCH system (see 87B, Passenger compartment
connection unit).
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF183/DP0TA2005_V18_DF183
MR-372-J84-23A100$406.mif

Page 50 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-50V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF185
PRESENT
OR
STOREDNO ABS/ESP MULTIPLEX SIGNAL
1.DEF: Carry out the multiplex network fault finding procedure
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the system (see 38C, ABS).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF185/DP0TA2005_V18_DF185