wiring RENAULT SCENIC 2007 J84 / 2.G Automatic Transmission Siemens TA2005 Workshop Manual

Page 2 of 139

AUTOMATIC TRANSMISSION
Fault finding - Introduction
23A
23A - 2V5 MR-372-J84-23A100$058.mif
123A
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type
Fault finding procedures (this manual):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM), paper.
Type of diagnostic tools
–CLIP
Special tooling required
3. RECAP
Procedure
To run fault finding on the vehicle computers, switch on the ignition.
Proceed as follows:
–Connect the diagnostic tool and perform the required operations. Vehicle(s): MEGANE II and SCENIC II
Function concerned: Automatic transmissionName of computer: Siemens TA 2005
Vdiag No.: 14-18
Special tooling required
Multimeter
Elé. 1681Universal bornier
WARNING
Computer supply for the fault finding procedure:
To run fault finding on the vehicle computers, proceed as follows:
–Place the vehicle's card in the card reader (keyless vehicle scenario 1 (entry level, not hands-free) and
scenario 2 (top of the range, hands-free),
–Press and hold the Start button (more than 5 seconds) outside start-up conditions,
–Then connect the diagnostic tool and perform the required operations.
DP0TA2005_V14_PRELI/DP0TA2005_V18_PRELI
MR-372-J84-23A100$058.mif

Page 5 of 139

AUTOMATIC TRANSMISSION
Fault finding - Introduction
23A
23A - 5V5 MR-372-J84-23A100$058.mif
SIEMENS TA2005
Vdiag No.: 14-18
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of the voltage, resistance and insulation are generally correct, especially if the fault is not
present when analysing (stored fault).
Visual inspection
Look for damage under the bonnet and in the passenger compartment.
Carefully check the fuses, insulators and wiring harness routing.
Look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored or
present.
Check that the connectors are correctly locked.
Apply light pressure to the connectors.
Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
Disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no crimping on
the insulating section).
Check that the clips and tabs are correctly locked in the sockets.
Make sure that no clips or tabs have been dislodged during connection.
Check the clip contact pressure using an appropriate model of tab.
Check the continuity/insulation
Check the continuity of entire lines, then section by section.
Look for a short circuit to earth, to + 12 V or to another wire.
If a fault is detected, repair or replace the wiring harness.

Page 16 of 139

Fault finding - Interpretation of faults23A
23A-16V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
DF003
PRESENT
OR
STOREDANALOGUE SENSOR SUPPLY
1.DEF: Voltage outside permitted range of values
NOTESSpecial notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Customer complaint: deterioration in gear shift strategies.
Deal first with faults: DF005 Oil pressure sensor circuit and DF023 Gearbox oil temperature sensor circuit.
Disconnect the battery.
Check the condition and cleanliness of the modular connector connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●connection code 5U, between components 119 and 781,
●connection code 5V, between components 119 and 781,
●connection code 5BC, between components 119 and 754,
●connection code 5BB, between components 119 and 754.
Check the supply of the analogue sensors = 5 V.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF003/DP0TA2005_V18_DF003
MR-372-J84-23A100$348.mif

Page 17 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-17V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF005
PRESENT
OR
STOREDOIL PRESSURE SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after a timed period of 10 seconds with the engine running
at 2000 rpm.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connection:
●connection code 5U, between components 119 and 781.
With the ignition on, check for + 5 V on connection 5U of the oil pressure sensor connector.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
●connection code 5W, between components 119 and 781,
●connection code 5V, between components 119 and 781.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The voltage on connection 5U of the modular connector must be + 5 V, otherwise check the computer supply.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 781 between connections 5V and 5W on the computer connector (female
connector).
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the sensor if the resistance is not approximately 20 kΩ.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF005/DP0TA2005_V18_DF005

Page 18 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-18V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
* CMF: Multifunction switch DF009
PRESENT
OR
STORED
MULTIFUNCTION SWITCH IN PROHIBITED POSITION
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears when the selector lever is moved from position P to position D with
a stop at each lever position.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Use the Mégane II or Scénic II wiring diagram Technical Note.
ACheck the consistency between: ET012 Gear lever position, the instrument panel display and the gear lever
position while shifting the lever into all the possible positions.
BTo check that there is no clearance between the gearbox output lever and the multifunction switch shaft, see
test 1 Checking the gearbox output lever clearance
–If there is clearance, check the tightness of the retaining nut. If this has no effect, replace the lever.
–If there is no clearance, move on to the next step.
CAdjust the control (see MR 370 Mechanical, 23A Automatic transmission, Automatic transmission control
unit (for Mégane II and Scénic II)).
–If the adjustment is correct, then the procedure is complete.
–If the adjustment is incorrect, move on to the next step.
DCheck the cleanliness, condition and mounting of the multifunction switch.
Check the adjustment of the CMF* in neutral (see MR 364 Mechanical, 23A Automatic transmission,
Multifunction switch, Removal - Refitting (for Mégane II) and MR 370 Mechanical, 23A Automatic
transmission, Multifunction switch, Adjustment (for Scénic II)).
–If the adjustment is incorrect, adjust the multifunction switch.
–If the adjustment is correct, move on to the next step.
ECheck the adjustment of the ball detent blade on the gearbox output lever at the unclipped external control
(see Technical Note 4194A: Automatic transmission indicator strip flashing):
–If the adjustment is incorrect, adjust the ball detent blade.
–If the check is correct, move on to the electrical check.
Repair if necessary.
Check the condition and cleanliness of the connector A connections.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF009/DP0TA2005_V18_DF009

Page 19 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-19V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF009
CONTINUED 1
Check for continuity on component 485 between the following connections:
Lever in position P
–Connection codes 5DG and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position R
–Connection codes 5DG and 5DK between components 119 and 485.
–Connection codes 5DH and 5DK between components 119 and 485.
–Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position N
–Connection codes 5DH and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position D
–Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the continuity is faulty, change the multifunction switch.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.

Page 20 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-20V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF009
CONTINUED 2
Check the insulation of component 485 on the following connections:
Lever in position P
●Connection codes 5DH and 5DK between components 119 and 485.
●Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position N
●Connection codes 5DG and 5DK between components 119 and 485.
●Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position D
●Connection codes 5DG and 5DK between components 119 and 485.
●Connection codes 5DH and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the insulation is faulty, replace the multifunction switch.
Check the cleanliness and condition of the connections.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●Connection code 5DG between components 119 and 485.
●Connection code 5DH between components 119 and 485.
●Connection code 5DJ between components 119 and 485.
●Connection code 5DK between components 119 and 485.
●If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.

Page 21 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-21V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF012
PRESENT
OR
STOREDSOLENOID VALVE SUPPLY
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
(see System operation and Allocation of computer tracks on the modular connector)
●connection code 5AU, between components 119 and 754,
●connection code 5AV, between components 119 and 754,
●connection code 5AX, between components 119 and 754,
●connection code 5AW, between components 119 and 754,
●connection code 5AY, between components 119 and 754,
●connection code 5DL, between components 119 and 754,
●connection code 5DM, between components 119 and 754,
●connection code 5BA, between components 119 and 754,
●connection code 5AZ, between components 119 and 754,
●connection code 5BX, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
With the ignition on, check for + 12 V on connections 5BA and 5AU of component 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF012/DP0TA2005_V18_DF012

Page 22 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-22V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF016
PRESENT
OR
STOREDLOCKUP SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control'.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
(see System operation and Allocation of computer tracks on the modular connector)
●connection code 5BX, between components 119 and 754.
●connection code 5BA, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5BX,
●connection code 5BA.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 1 Ω ± 0.12
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF016/DP0TA2005_V18_DF016

Page 23 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-23V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF017
PRESENT
OR
STOREDEXCHANGER FLOW RATE SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5DN, between components 119 and 1019,
●connection code 5DD, between components 119 and 1019.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 1019 between the following connections:
●connection code 5DN,
●connection code 5DD.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the exchanger flow solenoid valve or the wiring harness if the resistance is not 40 Ω ± 4 at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF017/DP0TA2005_V18_DF017

Page:   1-10 11-20 21-30 31-40 41-50 ... 60 next >