PARKING DISTANCE CONTROL
Vdiag No: 04-08
Fault finding - Introduction 87F - 2
Fault finding - System operation 87F - 7
Fault finding - Allocation of computer tracks 87F - 8
Fault finding - Replacement of components 87F - 10
Fault finding - Configurations and programming 87F - 11
Fault finding - Fault summary table 87F - 12
Fault finding - Interpretation of faults 87F - 13
Fault finding - Conformity check 87F - 28
Fault finding - Status summary table 87F - 30
Fault finding - Interpretation of statuses 87F - 31
Fault finding - Parameter summary table 87F - 39
Fault finding - Interpretation of parameters 87F - 40
Fault finding - Customer complaints 87F - 42
Fault finding - Fault Finding Chart 87F - 43
87F
MR-372-J84-87F000$000_engTOC.mif

Page 2 of 47

PARKING DISTANCE CONTROL
Fault finding - Introduction
87F
87F - 2V4 MR-372-J84-87F000$066_eng.mif
187F
Vdiag No: 04-08PARKING DISTANCE CONTROL
Fault finding - Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type
Fault finding procedures (this manual):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM), paper.
Type of diagnostic tools
–CLIP + multiplex line sensor
Special tooling required
3. RECAP
To run fault finding on the vehicle computers, switch on the ignition.
Depending on the type of vehicle equipment, proceed as follows:
To cut off the + after ignition feed, proceed as follows:Vehicle(s): CLIO III, Laguna II ph 1 and 2
Vel-Satis ph1 and 2,
Espace IV ph1 and 2,
Mégane II, Scénic II, Modus ph2Computer name: Parking distance control
Vdiag No: 04-08
Special tooling required
Multimeter
Elé. 1681 Universal bornier
For vehicles with radio frequency remote control/key,
switch on the ignition with the key.
For vehicles with a Renault card,
with the vehicle card in the card reader,
press and hold start button (longer than 5 seconds) with start-up conditions not fulfilled,
connect the diagnostic tool and perform the required operations.
For vehicles with key/radiofrequency remote control, use the key to switch off the ignition.
For vehicles with a Renault card,
press the Start button twice briefly (less than 3 seconds),
ensure that the + after ignition feed has been cut off by checking that the computer indicator lights on the
instrument panel have gone out.
AAP_V04_PRELI/AAP_V08_PRELI
MR-372-J84-87F000$066_eng.mif

Page 3 of 47

PARKING DISTANCE CONTROL
Fault finding - Introduction
87F
87F - 3V4 MR-372-J84-87F000$066_eng.mif
Vdiag No: 04-08
Faults
Faults are declared as either present or stored (depending on whether they appeared in a certain context and have
disappeared since, or whether they remain present but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is used following
the + after ignition supply being switched on (without operating the system components).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the instructions in the Notes section.
If the fault is confirmed when the instructions in the Notes section are applied, the fault is present. Deal with the fault
If the fault is not confirmed, check:
–the electrical lines which correspond to the fault,
–the connectors for these lines (for oxidation, bent pins, etc.),
–the resistance of the component detected as faulty,
–the condition of the wires (melted or split insulation, wear).
Conformity check
The aim of the conformity check is to check data that does not produce a fault on the diagnostic tool because the
data is inconsistent. Therefore, this stage is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer
complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section gives the fault finding procedures for statuses and parameters and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Customer complaints - Fault finding chart
If the test with the diagnostic tool is OK but the customer complaint is still present, the fault should be processed by
customer complaint.
A synopsis of the general procedure to follow is provided on the following page
in the form of a flow chart.

Page 4 of 47

PARKING DISTANCE CONTROL
Fault finding - Introduction
87F
87F - 4V4 MR-372-J84-87F000$066_eng.mif
Vdiag No: 04-08
4. FAULT FINDING PROCEDURE
Perform a pre-diagnostic on
the system
Print the system fault finding log
(available on CLIP and in the
Workshop Repair Manual or
Technical Note)
Connect CLIP
no
Dialogue with
computer?
yes
Read the faults
no
Faults
present
yes
Deal with present faults
Deal with stored faults
no
The cause is
still presentFault
solved
yes
Refer to ALP No. 1
Conformity check
no
The cause is
still presentFault
solved
Use fault finding charts (ALPs)
no
The cause is
still presentFault
solved
Contact the Techline with the
completed fault finding log

Page 5 of 47

PARKING DISTANCE CONTROL
Fault finding - Introduction
87F
87F - 5V4 MR-372-J84-87F000$066_eng.mif
Vdiag No: 04-08
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of voltage, resistance and insulation are generally correct, especially if the fault is not
present when the analysis is made (stored fault).
Visual inspection
Look for damage under the bonnet and in the passenger compartment.
Carefully check the fuses, insulators and wiring harness routing.
Look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored to
present.
Make sure that the connectors are properly locked.
Apply light pressure to the connectors.
Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
Disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no crimping on
the insulating section).
Make sure that the clips and tabs are properly locked in the sockets.
Check that no clips or tabs have been dislodged during connection.
Check the clip contact pressure using an appropriate model of tab.
Resistance check
Check the continuity of entire lines, then section by section.
Look for a short circuit to earth, to + 12 V or to another wire.
If a fault is detected, repair or replace the wiring harness.

Page 6 of 47

PARKING DISTANCE CONTROL
Fault finding - Introduction
87F
87F - 6V4 MR-372-J84-87F000$066_eng.mif
Vdiag No: 04-08
5. FAULT FINDING LOG
You will always be asked for this log:
●when requesting technical assistance from Techline,
●for approval requests when replacing parts for which approval is mandatory,
●to be attached to monitored parts for which reimbursement is requested. The log is needed for warranty
reimbursement, and enables better analysis of the parts removed.
6. SAFETY ADVICE
Safety rules must be observed during any work on a component to prevent any damage or injury:
–check the battery voltage to avoid incorrect operation of computer functions,
–use the appropriate tools,
–do not touch the xenon bulbs, and do not work on the COSLAD system when it is in operation, as the voltage can
be above 20,000 V. IMPORTANTIMPORTANT
Any fault on a complex system requires thorough fault finding with the appropriate tools. The
FAULT FINDING LOG, which should be completed during the procedure, enables you to keep
track of the procedure which is carried out. It is an essential document when consulting the
manufacturer.
IT IS THEREFORE ESSENTIAL THAT THE FAULT FINDING LOG IS FILLED OUT EVERY TIME IT IS
REQUESTED BY TECHLINE OR THE WARRANT RETURNS DEPARTMENT.

Page 7 of 47

PARKING DISTANCE CONTROL
Fault finding - System operation
87F
87F - 7V4 MR-372-J84-87F000$132_eng.mif
Vdiag No: 04-08PARKING DISTANCE CONTROL
Fault finding - System operation
Description of operation
The system consists of four sensors built into the rear bumper, a computer and a buzzer.
The system assists the driver during parking manoeuvres by warning of any obstacles to the rear of the vehicle.
–The sensors and the computer calculate the distance between the vehicle and any obstacles. The sensors operate
over a distance range from 20 - 30 cm minimum to 150 cm maximum.
–The driver is informed of the distances by a buzzer.
–The system only works when the vehicle is in reverse gear. Activation is indicated by a brief 0.5 second
activation sound.
The buzzer is activated when the vehicle is 150 cm from the obstacle. As the distance diminishes, the frequency of
the buzzer increases. When the distance reaches 20 - 30 cm, the buzzer becomes continuous.
–The system can only be activated in + after ignition feed.
DEACTIVATING THE SYSTEM:
–The parking distance control can be deactivated in two ways:
–Temporary deactivation: briefly pressing (1 second) the parking distance control switch on the dashboard
deactivates the system (the red warning light on the switch comes on). The function can be switched on again by
pressing briefly for a second time (the red indicator light on the switch goes out) or by switching the ignition off and
back on.
–Permanent deactivation: the parking distance control system can be deactivated for a longer period by pressing
and holding (for approximately 3 seconds) the parking distance control switch on the dashboard (the red warning
light on the switch comes on). The function can be switched on again only by pressing and holding the switch
again (the red warning light on the switch goes out).
Fault finding:
A low pitched, 5-second continuous warning sound upon switching on the ignition informs the driver that a
system fault has occurred.Note:
Using the diagnostic tool statuses, it is possible to find out the function status (ready, detecting, suspended or
disabled) by using status ET003 Parking distance control function (see conformity check or the relevant
status interpretation).
MR-372-J84-87F000$132_eng.mif

Page 8 of 47

PARKING DISTANCE CONTROL
Fault finding - Allocation of computer tracks87F
87F - 8V4 MR-372-J84-87F000$198_eng.mif
Vdiag No: 04-08PARKING DISTANCE CONTROL
Fault finding - Allocation of computer tracks
Computer with 1 connector (Clio III, Laguna II ph1 and 2, Vel Satis ph1 and 2 Espace IV ph 1 and 2 Mégane II,
Scénic II, Modus ph2):
Track Description
1+ 12 V after ignition feed
2+ 12 V buzzer
3Computer earth
4Reverse gear signal (+ 12 V)
5Warning light control
6Buzzer earth
7Not used
8Diagnostic line K
9+ 12 V rear sensors
10 Rear sensors earth
11 Not used
12 Parking distance control On/Off switch signal
13 Right-hand inner sensor signal
14 Left-hand inner sensor signal
15 Left-hand outer sensor signal
16 Right-hand outer sensor signal
Note:
For Scénic II, the computer and buzzer are located on the left-hand side of the luggage compartment behind the
interior trim.
MR-372-J84-87F000$198_eng.mif

Page 9 of 47

PARKING DISTANCE CONTROL
Fault finding - Allocation of computer tracks87F
87F - 9V4 MR-372-J84-87F000$198_eng.mif
Vdiag No: 04-08PARKING DISTANCE CONTROL
Fault finding - Allocation of computer tracks
Computer with 2 connectors (Laguna II ph1, Vel Satis ph1, Espace IV ph1):
12-TRACK CONNECTOR
16-TRACK CONNECTORTrack Description
1Not used
2Right-hand inner sensor signal
3Left-hand inner sensor signal
4Right-hand outer sensor signal
5Left-hand outer sensor signal
6Not used
7Not used
8Rear sensors earth
9Not used
10 Not used
11 + 12 V rear sensors
12 Not used
Track Description
1+ 12 V after ignition
2Buzzer earth
3Not used
4Parking distance control On/Off switch signal
5Not used
6Reverse gear signal (+ 12 V)
7Not used
8Computer earth
9Not used
10 + 12 V buzzer
11 Not used
12 Diagnostic line K
13 Warning light control
14 Not used
15 Not used
16 Not used

Page 10 of 47

PARKING DISTANCE CONTROL
Fault finding - Replacement of components
87F
87F - 10V4 MR-372-J84-87F000$264_eng.mif
Vdiag No: 04-08PARKING DISTANCE CONTROL
Fault finding - Replacement of components
REPLACING THE PARKING DISTANCE CONTROL COMPUTER
BEFORE REPLACING ANY COMPUTER IT IS ESSENTIAL THAT YOU CONTACT TECHLINE.
When replacing the computer, apply the following procedure:
–switch off the ignition,
–replace the parking distance control computer (see MR 392, 385, 405, 395, 364, 370 or 470 mechanical systems
87F parking distance control, parking distance control computer: Removal - Refitting),
–configure the vehicle identification using command CF005 Vehicle identification (refer to Configurations and
Programming),
–configure the volume of the buzzer and adjust the pitch using commands CF001 Buzzer volume and CF006
Adjusting the pitch (refer to Configurations and Programming),
–enter the VIN using command VP001 Enter VIN,
–check that the system is operating correctly and make sure that there are no faults.