Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
Page 51 of 406
Page 46 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
R elevant tests of IEC 60529 or Y.5.3 .................... : N/A
Y.5.3 Water spray test N/A
Y.5.4 Protection from plants and vermin N/A
Y.5.5 Protection from excessive dust N/A
Y.5.5.1 General N/A
Y.5.5.2 IP5X equipment N/A
Y.5.5.3 IP6X equipment N/A
Y.6 Mechanical strength of enclosures
N/A
Y.6.1 General N/A
Y.6.2 Impact test ................................ ............................. : N/A
Page 52 of 406
Page 47 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.2 TABLE: Classification of electrical energy sources
P
Supply
Voltage Location (e.g.
circuit
designation) Test conditions Parameters ES
Class
U (V) I (mA) Type 1 )
Addition al
Info 2 )
12 V d.c. Input power Normal 12 - - - ES1
Supplementary information:
1) Type: Steady state (SS), Capacitance (CP), Single pulse (SP), Repetitive pulses (RP) , etc.
2) Additional Info: Frequency, Pulse duration, Pulse off time, Capacitance val ue , etc.
5.4.1.8 TABLE: Working voltage measurement
N/A
Location RMS voltage
(V) Peak voltage
(V) Frequency
(Hz) Comments
Supplementary information:
5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics
N/A
Method ................................ ................................ ............................ : ISO 306 / B50
Object/ Part No./Material Manufacturer/trademark Thickness (mm) T softening (°C)
Supplementary information:
5.4.1.10.3 TABLE: Ball pressure test of thermoplastics
N/A
Allowed impression diameter (mm) ................................ ............... :
2 mm
Object/Part No./Material Manufac turer/trademark Thickness (mm) Test
temperature ( C) Impression
diameter (mm)
Supplementary information:
Page 53 of 406
Page 48 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.2, 5.4.3 TABLE: Minimum Clearances/Creepage distance
N/A
Clearance (cl) and
creepage distance
(cr) at/of/between: U
p
(V) U
rms
(V) Freq 1 )
(Hz) Required
cl (mm) cl
(mm) E.S. 2)
(V)
Required
cr (mm) cr
(mm)
Supplementary information:
1) O nly for frequency above 30 kHz
2) Complete Electric Strength voltage (E.S. (V) when 5.4.2.4 applied)
5.4.4.2 TABLE: Minimum distance through insulation
N/A
Distance through insulation
(DTI) at/of Peak voltage (V) Insulation Required DTI
(mm) Measured DTI
(mm)
Supplementary information:
5.4.4.9 TABLE: Solid insulation at frequencies >30 kHz
N/A
Insulation material E
P
Frequency
(kHz ) K
R
Thickness
d (mm) Insulation V
PW
(Vpk)
Supplementary information:
5.4.9 TABLE: Electric strength tests
N/A
Test voltage applied between: Voltage shape
(Surge, Impulse, AC,
DC, etc.) Test voltage (V) Breakdown
Yes / No
Supple mentary information:
Page 54 of 406
Page 49 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.5.2.2 TABLE: Stored discharge on capacitors
N/A
Location Supply voltage (V) Operating and fault
condition 1)
Switch
position Measured
voltage
(Vpk) ES Class
Supplementary information:
X - capacitors installed for testin g:
bleeding resistor rating:
ICX:
1) Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit
5.6.6 TABLE: Resistance of protective conductors and terminations
N/A
Loca tion Test current
(A) Duration
(min) Voltage drop
(V) Resistance
( Ω )
Supplementary information:
5.7.4 TABLE: Unearthed accessible parts
N/A
Location Operating and
fault conditions Supply
Voltage (V) Parameters ES
class
Voltage
(V
rms or V
pk ) Current
(A
rms or A
pk ) Freq.
(Hz)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
5.7.5 TABLE: Earthed accessible conductive part
N/A
Supply voltage (V) ........................... :
Phase(s) ................................ ......... : [] Single Phase; [ ] Three Pha se : [ ] Delta [ ] W ye
Power Distribution System ............. : TN TT IT
Location Fault Condition No in IEC
60990 clause 6.2.2 Touch current
(mA) Comment
Supplementary Information:
Page 55 of 406
Page 50 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.8 TABLE: Backfeed safeguard in battery backed up supplies
N/A
Location Supply
voltage (V) Operating and fault
condition Time (s) Open - circuit
voltage (V) Touch
current (A) ES Class
Supplementary information:
Abbreviation: SC= short circui t, OC= open circuit
6.2.2 TABLE: Power source circuit classifications
P
Location Operating and
fault condition Voltage (V) Current (A) Max.
Power 1)
(W) Time (S) PS class
Mains part - 1 2 V d.c. - - - PS3
(Declared)
Speaker
output W orst - case fault 7.38 1.85
( calculated ) 13.62 3 PS1
CN501
(49, GND) /
LCD PMR W orst - case fault 1.70 0.01 0.02 3 PS1
CN951
( 51, GND ) /
KEY_POW ER W orst - case fault 3.25 0.10 0.33 3 PS1
CN951
(17,GND) Worst - case fault 3.32 3.90 13.00 3 PS1
CN951
(1, GND) /
SYS 5.2 W orst - cas e fault 4.20 8.20 34.4 0 5
PS2
CN951
( 15 , GND ) /
VCC *) W orst - case fault 7.60 12.70 96.7 0 5
PS2
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
1) Measured after 3 s for PS1 and measured after 5 s for PS2 and PS3.
PS3: All combu stible materials except for PS2 and PS1 parts below.
PS2: Monitor circuit and keyboard circuit.
*) LCD module and keyboard power line .
Page 56 of 406
Page 51 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
6.2.3.1 TABLE: Determination of Arcing PIS
N/A
Location Open circuit voltage
after 3 s (V pk ) Measured r.m.s
current (A)
Calculated value
Arcing PIS?
Yes / No
Supplementary information:
6.2.3.2 TABLE: Determination of resistive PIS
P
Location Operating and fault condition Dissipate power (W) Arcing PIS?
Yes / No
Supplementary information:
Abbrevia tion: SC= short circuit; OC= open circuit
All components located within PS3 and PS2 are considered as resistive PIS.
A combination of voltmeter, VA and ammeter IA may be used instead of a wattmeter.
If a separate voltmeter and ammeter are used, the product of (VA x IA) is used to determine Resistive PIS
classification.
A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under
single fault conditions has either a power exceeding 100 W measured immediately after the introduction of
the fault if electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15
W measured 30 s after introduction of the fault.
8.5.5 TABLE: High pressure lamp
N/A
Lamp manufacturer Lamp type Explosion meth od Longest axis of
glass particle
(mm) Particle found
beyond 1 m
Yes / No
Supplementary information:
Page 57 of 406
Page 52 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
9.6 TABLE: Temperature measurements for wireless power transmitters
N/A
Supply voltage (V) ................................ .......... :
Max. transmit power of transmitter (W) .......... :
F oreign objects w/o receiver and
direct contact with receiver and
direct contact with receiver and at
distance of 2 mm with receiver and at
distance of 5 mm
Object
( o
C) Ambient
( o
C) Object
( o
C) Ambient
( o
C) Object
( o
C) Ambient
( o
C) Object
( o
C) Ambient
( o
C )
Supplementary information:
5.4.1.4 ,
9.3, B.1.5 ,
B.2.6 TABLE: Temperature measurements
P
Supply voltage (V) ................................ .......... : 14.4 V
d.c. 14.4 V
d.c. 14.4 V
d.c.
Ambient temperature during test T
amb ( C) .... : 21.0 25 1)
85 2)
Maximum measured tempe rature T of part/at:
T ( C) Allowed
T
max ( C)
1. Display PCB near IC100 43.6 - 107.6 130
2. Display panel body (Not accessible) 51.1 - 115.1 -
3. Connector body (CN310) 46.1 - 110.1 -
4. PCB near SD card slot 45.1 - 109.1 130
5. Main PCB near CN15 0 44.9 - 108.9 130
6. Main PCB near IC 402 65.7 - 129.7 130
7. Main PCB near L304 52.3 - 116.3 130
8. Main to Display connector body (CN951) 57.6 - 121.6 -
9. PCB near BD7820 64.7 - 128.7 130
10. PCB near CN151 46.7 - 110.7 130
11. Amp IC body (IC163) 78.3 - 142.3 -
12. PCB near C298 56.8 - 120.8 130
13. Main to Antenna connector body (CN990) 54.1 - 118.1 -
14. Antenna PCB near IC182 61.3 - 125.3 130
15. Monitor body 37.4 41.4 - 71
Page 58 of 406
Page 53 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
16. Power key knob body 25.5 29.5 - 60
17. Enclosure near media button 28.6 32.6 - 77
18. Frame body (Not accessible) 34.4 - 98.4 -
19. Metal enclosure body (Not accessible) 40.4 - 104.4 -
Ambient temperature See
above See
above See
above -
Temperature T of winding: t
1 (°C)
R
1 ( ) t
2 (°C)
R
2 ( ) T ( C) Allowed
T
max ( C) Insulation
class
Supplementary information:
Note 1. The temperatures for accessible parts are adjusted to reflect a value of 25 °C .
Note 2. Maximum operating Temperature pe rmitted by the Manufacturer(Tma) is 85 C .
B.2.5 TABLE: Input test
P
U (V) Hz I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
10.2 -
2.31 -
23.56 - - -
Max. normal
load condition.
12.0 -
2.20 3.5
26.40 - - -
Max. normal
load condition.
14.4 -
2.16 -
31.10 - - -
Max. normal
lo ad condition.
Supplementary information:
Max. normal load condition : The equipment is operated in such a way as to deliver one - eighth of the NON -
CLIPPED OUTPUT POWER to the RATED LOAD IMPEDANCE ( 4Ω ) using the standard signal described
in Annex E and Max. brightness for LCD module.
Page 59 of 406
Page 54 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
B.3, B.4 TABLE: Abnormal operating and fault condition tests
P
Ambient temperature T
amb ( C) ................................ ..................... : 2 1 - 2 3
Power source for EUT: Manufacturer, model/type, outputrating .. : -
Component No. Condition Supply
voltage
(V) Test
tim e Fuse no. Fuse
current
(A) Observation
Ventilation
openings Block ed 14.4 2 h - - FI : 2.16 A, NO,
CT (Monitor body : 3 8.0 C,
Power key knob body : 2 6.1
C, Enclosure near media
button : 29.4 C, Ambient :
2 1.2 C, NCD, NH
Speaker output Max. non -
clipp ed output 14.4 2 h - - FI : Max. 3.43 A, NO,
CT ( Amp IC body (IC163) :
80.4 C , Monitor body : 3 8.0
C, Power key knob body :
26.3 C, Enclosure near
media button : 29.5 C,
Ambient : 2 1.5 C, NCD, NH
Speaker output SC 14.4 1 h - - FI : 0.5 - 1.5 5 A , IP , NCD,
NH
IC101(3,8) SC 14.4 1 h - - FI : 0.5 A , CD(IC101) , NH
IC902(1,6) SC 14.4 1 h - - FI : 0.5 A , CD(IC902) , NH
Supplementary information:
Abbreviation:
FI – Final Input Current; IP – Internal protection operated; NO – Normal Operated;
CD – Componen t Damaged (list damaged components); NCD – No Component Damaged;
NH – No Hazard ; CT – Constant temperatures were obtained (list components: temperature;);
NB – No indication of dielectric breakdown; YB – Dielectric breakdown (indicate time and location);
NC – Cheesecloth remained intact; YC – Cheesecloth charred or flamed;
Page 60 of 406
Page 55 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
M.3 TABLE: Protection circuits for batteries provided within the equipment
N/A
Is it possible to install the battery in a reverse polarity position? ...... :
Equipment Specification Ch arging
Voltage (V) Current (A)
Manufacturer/type Battery specification
Non - rechargeable batteries Rechargeable batteries
Discharging
current (A) Unintentional
charging
current (A) Charging Discharging
current (A) Reverse
charging
current (A) Voltage (V) Current (A)
Note: The tests of M.3.2 are applicable only when above appropriate data is not available.
Specified battery temperature ( o
C) ................................ ................... :
Componen
t No. Fault
condition Charge/
discharge mode Test
time Temp.
( o
C) Current
(A) V oltage
(V) Observation
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit NL= no chemical leakage; NS= no spillage of liquid; NE=
no explosion; NF= no emission of flame or expulsion of molten metal.
M.4.2 TABLE: Charg ing safeguards for equipment containing a secondary lithium
battery N/A
Maximum specified charging voltage (V) ................................ ..... :
Maximum specified charging current (A) ................................ ..... :
Highest specified charging temperature ( o
C) .............................. :
Lowest specified charging temperature ( o
C) ............................... :
Battery
manufacturer/type Operating
and fault
condition Measurement Observation
Charging
voltage (V) Charging
current (A) Temp.
( o
C)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified c harging voltage; MSCC=
maximum specified charging current; HSCT= highest specified charging temperature; LSCT= lowest
specified charging temperature