Page 86 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
the building installation through the mains
connection or through other apparatus with a
connection to protective earthing –
and to a television distribution system using coaxial
cable, may in some circumstances cr eate a fire
hazard. Connection to a television distribution
system therefore has to be provided through a
device providing electrical isolation below a certain
frequency range (galvanic isolator, see EN 60728 -
11)”
NOTE In Norway, due to regulation for CAT V - installations, and in
Sweden, a galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a dielectric strength
of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Apparater som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et koaksialbasert kabel - TV
nett, kan forå rsake brannfare.
For å unngå dette skal det ved tilkopling av
apparater til kabel - TV nett installeres en
galvanisk isolator mellom apparatet og kabel - TV
nettet.”
Translation to Swedish:
”Apparater som är kopplad till skyddsjord via jordat
vä gguttag och/eller via annan utrustning och
samtidigt ä r kopplad till kabel - TV nä t kan i v issa fall
medfőra risk főr brand. Főr att undvika detta skall vid
anslutning av apparaten till kabel - TV nä t galvanisk
isolator finnas mellan apparaten och kabel - TV
nätet.”.
8.5.4.2.3 United Kingdom
Add the following after the 2 nd
dash bullet in 3 rd
paragraph:
An emergency stop system complying with the
requirements of IEC 60204 - 1 and ISO 13850 is
required where there is a risk of personal injury. N/A
Page 92 of 406

Page 87 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
B.3.1 and
B.4 Ireland and United Kingdom
The following is applicable:
To protect against exce ssive currents and short -
circuits in the primary circuit of direct plug - in
equipment , tests according to Annexes B.3.1 and
B.4 shall be conducted using an external miniature
circuit breaker complying with EN 60898 - 1, Type B,
rated 32A. If the equipment doe s not pass these
tests, suitable protective devices shall be included
as an integral part of the direct plug - in equipment ,
until the requirements of Annexes B.3.1 and B.4 are
met N/A
G.4.2 Denmark
To the end of the subclause the following is added:
Sup ply cords of single phase appliances having a
rated current not exceeding 13 A shall be provided
with a plug according to DS 60884 - 2 - D1:2011.
CLASS I EQUIPMENT provided with socket - outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2 - 1a or DK 2 - 5a.
If a single - phase equipment having a RATED
CURRENT exceeding 13 A or if a polyphase
equ ipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN
60309 - 2.
Mains socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A shal l
be in accordance DS 60884 - 2 - D1:2011 standard
sheet DKA 1 - 4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1 - 3a
or DKA 1 - 1c.
Mains socket - outlets with earth shall be in
compliance with DS 60884 - 2 - D1:2011
Standard Sh eet DK 1 - 3a, DK 1 - 1c, DK1 - 1d, DK 1 - 5a
or DK 1 - 7a
Justification:
Heavy Current Regulations, Section 6c N/A
Page 93 of 406

Page 88 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
G.4.2 United Kingdom
To the end of the subclause the following is added:
The plug part of direct plug - in equipment shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9,
12.11, 12.12, 12.13, 12.16, and 12.17, except that
the test of 12.17 is performed at not less than
125 °C. Where the metal earth pin is replaced by an
Insulated Shutter Opening Device (ISOD), the
requirements of clauses 22.2 and 23 also apply. N/A
G.7.1 United Kingdom
To the first paragraph the following is added:
Equipment which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord shall be fitted with a ‘standard
plug’ in accordance with the Plugs and Sockets etc.
(Safety) Regulations 1994, Statutory Instrument
1994 No. 1768, unless exempted by those
regulations.
NOTE "Standard plug" is defined in SI 1768:1994 and essentia lly
means an approved plug conforming to BS 1363 or an approved
conversion plug. N/A
G.7.1 Ireland
To the first paragraph the following is added:
Apparatus which is fitted with a flexible cable or cord
shall be provided with a plug in accordance with
S tatutory Instrument 525: 1997, “13 A Plugs and
Conversion Adapters for Domestic Use Regulations:
1997. S.I. 525 provides for the recognition of a
standard of another Member State which is
equivalent to the relevant Irish Standard N/A
G.7.2 Ireland and Un ited Kingdom
To the first paragraph the following is added:
A power supply cord with a conductor of 1,25 mm 2
is
allowed for equipment which is rated over 10 A and
up to and including 13 A. N/A
Page 94 of 406

Page 89 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN)
N/A
10.5.2 Germany
The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type
approval (Bauartzulassung) and marking.
Justification :
German ministerial decree against ionizing radiation
(Rö ntgenverordnung), in force since
2002 - 07 - 01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch - Technische Bundesanstalt, Bundesallee 100, D -
38116 Braunschweig,
Tel.: Int+49 - 531 - 592 - 6320, Internet: http://www.ptb.de N/A
Page 95 of 406

Page 90 of 90 Report No. : 60404487 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
ZD IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS (EN)
N/A
N/A
Page 96 of 406

Report Number…….....:
60404487 001
Model…………………...:
L60SK2 , MIB2GP, L73SK2, L72SK2, L81SK2
P age 1 of 12
Front view for model L60SK2
Rear view for model L60SK2
Page 97 of 406

Report Number…….....:
60404487 001
Model…………………...:
L60SK2 , MIB2GP, L73SK2, L72SK2, L81SK2
P age 2 of 12
Top view for model L60SK2
Bottom view for model L60SK2
Page 98 of 406

Report Number…….....:
60404487 001
Model…………………...:
L60SK2 , MIB2GP, L73SK2, L72SK2, L81SK2
P age 3 of 12
Side view for model L60SK2
Page 99 of 406

Report Number…….....:
60404487 001
Model…………………...:
L60SK2 , MIB2GP, L73SK2, L72SK2, L81SK2
P age 4 of 12
Inside view for model L60SK2
Inside view for model L60SK2
Page 100 of 406

Report Number…….....:
60404487 001
Model…………………...:
L60SK2 , MIB2GP, L73SK2, L72SK2, L81SK2
P age 5 of 12
Main PCB Top view for model L60SK2
Main PCB Bottom view for model L60SK2