SUBARU LEGACY 1996 Service Repair Manual
Page 2091 of 2890
WIRING DIAGRAM:
LHD Model
B2M0534
323
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code
Page 2092 of 2890
WIRING DIAGRAM:
RHD Model
B2M0786
B2M0596A
10BL1
CHECK OUTPUT SIGNAL FROM ECM.
1) Turn ignition switch to ON.
2) Measure voltage between ECM and chassis ground.
: Connector & terminal
(B84) No. 15 (+)—Chassis ground ( ):
Is the voltage more than 10 V?
: Go to step10BL2.
: Go to step10BL3.
324
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code
Page 2093 of 2890
B2M0596A
10BL2CHECK HARNESS BETWEEN ECM AND
PRESSURE SOURCES SWITCHING
SOLENOID VALVE CONNECTOR.
1) Turn ignition switch to OFF.
2) Disconnect connector from pressure sources switching
solenoid valve.
3) Turn ignition switch to ON.
4) Measure voltage between ECM and chassis ground.
: Connector & terminal
(B84) No. 15 (+)—Chassis ground ( ):
Is the voltage more than 10 V?
: Repair short circuit in harness between ECM and
pressure sources switching solenoid valve con-
nector and replace ECM.
: Go to next step 5).
OBD0485
5) Turn ignition switch to OFF.
6) Measure resistance between pressure sources switch-
ing solenoid valve connector terminals.
: Terminals
No. 1—No. 2:
Is the resistance less than 1Ω?
: Replace pressure sources switching solenoid
valve and ECM.
: Go to next.
: Is there poor contact in ECM connector?
: Repair poor contact in ECM connector.
: Replace ECM.
325
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code
Page 2094 of 2890
OBD0488A
10BL3CHECK HARNESS BETWEEN ECM AND
PRESSURE SOURCES SWITCHING
SOLENOID VALVE CONNECTOR.
1) Turn ignition switch to OFF.
2) Disconnect connector from pressure sources switching
solenoid valve and ECM.
3) Measure resistance of harness between pressure
sources switching solenoid valve connector and engine
ground.
: Connector & terminal
(B1) No. 1—Engine ground:
Is the resistance less than 10Ω?
: Repair short circuit in harness between ECM and
pressure sources switching solenoid valve con-
nector.
: Go to next step 4).
B2M0597A
4) Measure resistance of harness between ECM and pres-
sure sources switching solenoid valve connector.
: Connector & terminal
(B84) No. 15—(B1) No. 1:
Is the resistance less than 1Ω?
: Go to step10BL4.
: Repair open circuit in harness between ECM and
pressure sources switching solenoid valve con-
nector.
OBD0485
10BL4CHECK PRESSURE SOURCES SWITCH-
ING SOLENOID VALVE.
Measure resistance between pressure sources switching
solenoid valve connector terminals.
: Terminals
No. 1—No. 2:
Is the resistance between 10 and 100Ω?
: Go to step10BL5.
: Replace pressure sources switching solenoid
valve.
326
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code
Page 2095 of 2890
OBD0676A
10BL5CHECK POWER SUPPLY TO PRESSURE
SOURCES SWITCHING SOLENOID
VA LV E .
1) Turn ignition switch to ON.
2) Measure voltage between pressure sources switching
solenoid valve harness connector and engine ground.
: Connector & terminal
(B1) No. 2 (+)—Engine ground ( ):
Is the voltage more than 10 V?
: Go to next.
: Repair open circuit in harness between main relay
and pressure sources switching solenoid valve
connector.
: Is there poor contact in pressure sources
switching solenoid valve connector?
: Repair poor contact in pressure sources switching
solenoid valve connector.
: Contact with SOA service.
NOTE:
Inspection by DTM is required, because probable cause is
deterioration of multiple parts.
327
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code
Page 2096 of 2890
OBD0489
BM: DTC P1103
—ENGINE TORQUE CONTROL SIGNAL
CIRCUIT MALFUNCTION (TRQ)—
DTC DETECTING CONDITION:
Two consecutive trips with fault
TROUBLE SYMPTOM:
Excessive shift shock
10BM1Check input signal for ECM.
10BM2Check harness between ECM and TCM
connector.
CAUTION:
After repair or replacement of faulty parts, conduct
CLEAR MEMORY and INSPECTION MODES.
<Ref. to 2-7 [T3D0] and [T3E0].>
WIRING DIAGRAM:
B2M0598
328
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostics Chart with Trouble Code