Iat DAEWOO LACETTI 2004 Service Repair Manual
[x] Cancel search | Manufacturer: DAEWOO, Model Year: 2004, Model line: LACETTI, Model: DAEWOO LACETTI 2004Pages: 2643, PDF Size: 80.54 MB
Page 1511 of 2643

5A1 – 162IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1863
EDS 4 OUTPUT OPEN
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output ampere of the EDS 4 is less than 10mA.
S No DTC P1861, P1862.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1863 sets, the possible cause of fault
could be EDS4 valve.
Page 1513 of 2643

5A1 – 164IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1864
EDS 5 OUTPUT SHORTED TO GROUND
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output voltage of the EDS 5 is less than 2 volt.
S No DTC P1865, P1866.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1864 sets, the possible cause of fault
could be EDS valve.
Page 1515 of 2643

5A1 – 166IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1865
EDS 5 OUTPUT SHORTED TO POWER
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output voltage of the EDS 5 (at ON) is 12 volt.
S No DTC P1864, P1866.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1865 sets, the possible cause of fault
could be EDS5.
Page 1517 of 2643

5A1 – 168IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1866
EDS 5 OUTPUT OPEN
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output ampere of the EDS 5 is less than 10mA.
S No DTC P1864, P1865.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1866 sets, the possible cause of fault
could be EDS valve.
Page 1519 of 2643

5A1 – 170IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1867
EDS 6 OUTPUT SHORTED TO GROUND
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output voltage of the EDS 6 is less than 2 volt.
S No DTC P1868, P1869.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1867 sets, the possible cause of fault
could be EDS valve.
Page 1521 of 2643

5A1 – 172IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1868
EDS 6 OUTPUT SHORTED TO POWER
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output voltage of the EDS 6 (at ON) is 12 volt.
S No DTC P1867, P1869.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1868 sets, the possible cause of fault
could be TCM.
Page 1523 of 2643

5A1 – 174IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1869
EDS 6 OUTPUT OPEN
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S Output ampere of the EDS 6 is less than 10mA.
S No DTC P1867, P1868.
S Immediately after the above condition occurs.
Action Taken When The DTC SetsS The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1869 sets, the possible cause of fault
could be EDS valve.
Page 1525 of 2643

5A1 – 176IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1871
EDS VALVE POWER SUPPLY CIRCUIT SHORTED TO
POWER
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S If the voltage applied to high side driver is higher
than the threshold(6V) with high side driver switch
off status then a fault is detected.
S No DTC P1870.
S Immediately after the above condition occurs.
Action Taken When The DTC SetsS The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1871 sets, the possible cause of fault
could be EDS valve power supply line.
Page 1527 of 2643

5A1 – 178IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P1874
SOLENOID VALVE POWER SUPPLY CIRCUIT SHORTED
TO POWER
Circuit Description
The pressure control valves (EDS valves 3,4,5 and 6) are
precision electronic pressure regulators that control the
operation of the clutches, brakes and lock–up clutch.
The valve reduces the system pressure with which the
downstream solenoid valves and electrical pressure regu-
lating valves are supplied. It is possible to use smaller so-
lenoid valves as a result. The EDS require a constant input
pressure.
Conditions for Setting the DTC
S No DTC P1873.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear.
S Power supply cut off to the EDS valve.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1874 sets, the possible cause of fault
could be solenoid valve power supply line.
Page 1530 of 2643

ZF 4 HP 16 AUTOMATIC TRANSAXLE 5A1 – 181
DAEWOO V–121 BL4
S No input speed error DTCs P0715, P0716, or
P0717.
S Output speed is greater than 256 rpm.
S Input speed is greater than 400 rpm.
S 2–1 gear shift is active.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
3rd gear.S Open lock–up clutch.
Conditions for Clearing the MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P1881 sets, the possible cause of fault
could be TCM.
DTC P1881 – 2–1 Shift Malfunction
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Is the check completed?–Go to Step 2Go to ”On–
Board Diagnos-
tic System
Check”
21. Install the scan tool.
2. Turn the ignition ON, with the engine OFF.
Then, start engine and allow it to warm up at
idle.
3. Observe ”idle rpm, TPS” on the scan tool.
Was a problem found?–Go to ”Engine
Diagnostic In-
formation”Go to Step 3
3Inspect ”ECM”. Refer to Section 1F, System Diagno-
sis, EOBD System Check.
Was a problem found?–Go to ”Engine
Diagnostic In-
formation”Go to Step 4
41. Turn the ignition OFF.
2. Disconnect the TCM wiring connector.
3. Measure the voltage between terminal B3 and
B13 of the transaxle wiring connector.
4. Turn the ignition ON.
5. Measure the voltage between terminal C15 and
B13 of the transaxle wiring connector.
6. Measure the voltage between terminal C16 and
B13 of the transaxle wiring connector.
Is the voltage within the values shown?11–14VGo to Step 5Go to ”System
Voltage Low or
High”
5Replace the TCM.
Is the action complete?–Go to Step 6–
61. After the repair, use a scan tool ”clear info”
function and road test the vehicle.
2. Review the ”DTC info”.
Has the last test failed or is the current DTC dis-
played?–Replace the
transaxle as-
semblyRepair verified
exit DTC chart