A1 CHECK THE BATTERY POWER SUPPLY TO THE INSTRUMENT
CLUSTER CAUTION: Use the correct probe adapter(s) when making
measurements. Failure to use the correct probe adapter(s) may
damage the connector.
z Key in OFF position.
z Disconnect: Instrument Cluster C220b.
z Measure voltage between the instrument cluster C220b pin 10,
circuit 729 (RD/WH), harness side and ground.
z Is the voltage greater than 10 volts? Yes
GO to
A2 .
No
REPAIR the circuit.
TEST the system
for normal
operation. A2 CHECK THE RUN POWER SUPPLY TO THE INSTRUMENT
CLUSTER z
Key in ON position.
z Measure the voltage between the instrument cluster C220b pin 11,
circuit 489 (PK/BK), harness side and ground.
z Is the voltage greater than 10 volts? Yes
GO to
A3 .
No
REPAIR the circuit.
TEST the system
for normal
operation. A3 CHECK THE RUN/START POWER SUPPLY TO THE INSTRUMENT
CLUSTER z
Key in OFF position.
z Disconnect: Instrument Cluster C220b.
z Key in ON position.
z Measure the voltage between the instrument cluster C220b pin 12,
circuit 20 (WH/LB), harness side and ground.
z Is the voltage greater than 10 volts? Yes
GO to
A4 .
No
REPAIR the circuit.
TEST the system
for normal
operation. Klj . 14 ba
412003 Mustang Workshop Manual