sensor INFINITI FX35 2005 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2005, Model line: FX35, Model: INFINITI FX35 2005Pages: 4731, PDF Size: 60.13 MB
Page 2440 of 4731
![INFINITI FX35 2005 Service Manual DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1047
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
3. CHECK CAMSHAFT POSITION (CMP) SENSOR (PHASE) POWER SUPPLY CIRCU INFINITI FX35 2005 Service Manual DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1047
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
3. CHECK CAMSHAFT POSITION (CMP) SENSOR (PHASE) POWER SUPPLY CIRCU](/img/42/57020/w960_57020-2439.png)
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1047
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
3. CHECK CAMSHAFT POSITION (CMP) SENSOR (PHASE) POWER SUPPLY CIRCUIT
1. Disconnect camshaft position (CMP) sensor (PHASE) harness connector.
2. Turn ignition switch ON.
3. Check voltage between CMP sensor (PHASE) terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors F102, M82
Harness for open or short between camshaft position sensor (PHASE) and ECM
Harness for open or short between camshaft position sensor (PHASE) and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK CMP SENSOR (PHASE) GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between CMP sensor (PHASE) terminal 1 and ground.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F102, M82
Harness for open or short between CMP sensor (PHASE) and ground
>> Repair open circuit or short to power in harness or connectors.
PBIB1499E
Voltage: Battery voltage
SEF481Y
Continuity should exist.
Page 2441 of 4731
![INFINITI FX35 2005 Service Manual EC-1048
[VK45DE]
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
Revision: 2005 July 2005 FX
7. CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector. INFINITI FX35 2005 Service Manual EC-1048
[VK45DE]
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
Revision: 2005 July 2005 FX
7. CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.](/img/42/57020/w960_57020-2440.png)
EC-1048
[VK45DE]
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
Revision: 2005 July 2005 FX
7. CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 14 and CMP sensor (PHASE) terminal 2. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK CAMSHAFT POSITION SENSOR (PHASE)
Refer to EC-1049, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace camshaft position sensor (PHASE).
9. CHECK CAMSHAFT SPROCKET (EXHAUST)
Visually check camshaft sprocket (exhaust) for chipping.
OK or NG
OK >> GO TO 10.
NG >> Replace camshaft sprocket (exhaust).
10. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Continuity should exist.
Page 2442 of 4731
![INFINITI FX35 2005 Service Manual DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1049
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS007YW
CAMSHAFT POSITION SENSOR (PHASE)
1. L INFINITI FX35 2005 Service Manual DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1049
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS007YW
CAMSHAFT POSITION SENSOR (PHASE)
1. L](/img/42/57020/w960_57020-2441.png)
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE) EC-1049
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS007YW
CAMSHAFT POSITION SENSOR (PHASE)
1. Loosen the fixing bolt of the sensor.
2. Disconnect camshaft position sensor (PHASE) harness connector.
3. Remove the sensor.
4. Visually check the sensor for chipping.
5. Check resistance as shown in the figure.
Removal and InstallationABS007YX
CAMSHAFT POSITION SENSOR (PHASE)
Refer to EM-212, "CAMSHAFT" .
PBIB0563E
Terminal No. (Polarity) Resistance Ω [at 25 °C (77 °F)]
3(+) - 1 (-) Except 0 or ∞
2 (+) - 1 (-)
3 (+) - 2 (-)
PBIB0564E
Page 2443 of 4731
![INFINITI FX35 2005 Service Manual EC-1050
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS00E5B
The ECM monitors the sw INFINITI FX35 2005 Service Manual EC-1050
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS00E5B
The ECM monitors the sw](/img/42/57020/w960_57020-2442.png)
EC-1050
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS00E5B
The ECM monitors the switching frequency ratio of heated oxygen
sensors 1 and 2.
A three way catalyst (Manifold) with high oxygen storage capacity
will indicate a low switching frequency of heated oxygen sensor 2.
As oxygen storage capacity decreases, the heated oxygen sensor 2
switching frequency will increase.
When the frequency ratio of heated oxygen sensors 1 and 2
approaches a specified limit value, the three way catalyst (Manifold)
malfunction is diagnosed.
DTC Confirmation ProcedureABS00E5C
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
2. Start engine and warm it up to the normal operating tempera- ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C
(158 °F).
If not, warm up engine and go to next step when “COOLAN
TEMP/S” indication reaches to 70 °C (158 °F).
7. Open engine hood.
SEF484YF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420
(Bank 1)
Catalyst system efficiency
below threshold
Three way catalyst (Manifold) does not operate
properly.
Three way catalyst (Manifold) does not have
enough oxygen storage capacity.
Three way catalyst (Manifold)
Exhaust tube
Intake air leaks
Fuel injector
Fuel injector leaks
Spark plug
Improper ignition timing
P0430
0430
(Bank 2)
SEF174Y
Page 2445 of 4731
![INFINITI FX35 2005 Service Manual EC-1052
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
7. Make sure that the voltage switching frequency (high & low)
between ECM terminals 55 and ground, or 74 and INFINITI FX35 2005 Service Manual EC-1052
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
7. Make sure that the voltage switching frequency (high & low)
between ECM terminals 55 and ground, or 74 and](/img/42/57020/w960_57020-2444.png)
EC-1052
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
7. Make sure that the voltage switching frequency (high & low)
between ECM terminals 55 and ground, or 74 and ground is
very less than that of ECM terminals 16 and ground, or 35 and
ground.
Switching frequency ratio = A/B
A: Heated oxygen sensor 2 voltage switching frequency
B: Heated oxygen sensor 1 voltage switching frequency
This ratio should be less than 0.75.
If the ratio is greater than above, it means three way catalyst
does not operate properly. Go to EC-1052, "
Diagnostic Proce-
dure" .
NOTE:
If the voltage at terminal 16 or 35 does not switch periodically more than 5 times within 10 seconds at step 5,
perform trouble diagnosis for “DTC P0133, P0153” first. (See EC-944
.)
Diagnostic ProcedureABS00E5E
1. CHECK EXHAUST SYSTEM
Visually check exhaust tubes and muffler for dent.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace.
2. CHECK EXHAUST GAS LEAK
1. Start engine and run it at idle.
2. Listen for an exhaust gas leak before the three way catalyst (Manifold).
OK or NG
OK >> GO TO 3.
NG >> Repair or replace.
3. CHECK INTAKE AIR LEAK
Listen for an intake air leak after the mass air flow sensor.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace.
PBIB1529E
SEC502D
Page 2449 of 4731
![INFINITI FX35 2005 Service Manual EC-1056
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
DTC P0441 EVAP CONTROL SYSTEMPFP:14950
System DescriptionABS007NQ
NOTE:
If DTC P0441 is displayed with other DTC such as P21 INFINITI FX35 2005 Service Manual EC-1056
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
DTC P0441 EVAP CONTROL SYSTEMPFP:14950
System DescriptionABS007NQ
NOTE:
If DTC P0441 is displayed with other DTC such as P21](/img/42/57020/w960_57020-2448.png)
EC-1056
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
DTC P0441 EVAP CONTROL SYSTEMPFP:14950
System DescriptionABS007NQ
NOTE:
If DTC P0441 is displayed with other DTC such as P2122, P2123, P2127, P2128 or P2138, first perform
trouble diagnosis for other DTC.
In this evaporative emission (EVAP) control system, purge flow occurs during non-closed throttle conditions.
Purge volume is related to air intake volume. Under normal purge conditions (non-closed throttle), the EVAP
canister purge volume control solenoid valve is open to admit purge flow. Purge flow exposes the EVAP con-
trol system pressure sensor to intake manifold vacuum.
On Board Diagnosis LogicABS007NR
Under normal conditions (non-closed throttle), sensor output voltage indicates if pressure drop and purge flow
are adequate. If not, a malfunction is determined.
DTC Confirmation ProcedureABS007NS
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
PBIB1026E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0441
0441 EVAP control system
incorrect purge flow EVAP control system does not operate prop-
erly, EVAP control system has a leak between
intake manifold and EVAP control system pres-
sure sensor.
EVAP canister purge volume control
solenoid valve stuck closed
EVAP control system pressure sensor
and the circuit
Loose, disconnected or improper con-
nection of rubber tube
Blocked rubber tube
Cracked EVAP canister
EVAP canister purge volume control
solenoid valve circuit
Accelerator pedal position sensor
Blocked purge port
EVAP canister vent control valve
Page 2450 of 4731
![INFINITI FX35 2005 Service Manual DTC P0441 EVAP CONTROL SYSTEM EC-1057
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. INFINITI FX35 2005 Service Manual DTC P0441 EVAP CONTROL SYSTEM EC-1057
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2.](/img/42/57020/w960_57020-2449.png)
DTC P0441 EVAP CONTROL SYSTEM EC-1057
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 70 seconds.
4. Select “PURG FLOW P0441” of “EVAPORATIVE SYSTEM” in “DTC CONFIRMATION” mode with CON- SULT-II.
5. Touch “START”. If “COMPLETED” is displayed, go to step 7.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-II screen. Maintain the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
1058, "Diagnostic Procedure" .
Overall Function CheckABS007NT
Use this procedure to check the overall monitoring function of the EVAP control system purge flow monitoring.
During this check, a 1st trip DTC might not be confirmed.
WITH GST
1. Lift up drive wheels.
2. Start engine (VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF, wait at least 10 seconds.
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM terminals 32 (EVAP control system pressure sensor signal) and ground.
6. Check EVAP control system pressure sensor value at idle speed and note it.
7. Establish and maintain the following conditions for at least 1 minute.
8. Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (mea- sured at step 6) for at least 1 second.
Selector lever Suitable position
Vehicle speed 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,000 rpm
B/FUEL SCHDL 1.0 - 10.0 msec
Engine coolant temperature 70 - 100 °C (158 - 212 °F)
PBIB0826E
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Gear position Any position other than P, N or R
PBIB1109E
Page 2453 of 4731
![INFINITI FX35 2005 Service Manual EC-1060
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
8. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector. INFINITI FX35 2005 Service Manual EC-1060
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
8. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.](/img/42/57020/w960_57020-2452.png)
EC-1060
[VK45DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
8. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
OK or NG
OK >> GO TO 9.
NG >> Replace EVAP control system pressure sensor.
9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR FUNCTION
Refer to DTC P0452 EC-1087, "
DTC Confirmation Procedure" , P0453 EC-1093, "DTC Confirmation Proce-
dure" .
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP control system pressure sensor.
10. CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 11.
NG >> Clean the rubber tube using an air blower.
11 . CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-1081, "
Component Inspection" .
OK or NG
OK >> GO TO 12.
NG >> Replace EVAP canister vent control valve.
12. CHECK EVAP PURGE LINE
Inspect EVAP purge line (pipe and rubber tube). Check for evidence of leaks.
Refer to EC-731, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 13.
NG >> Replace it.
13. CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 14.
14. CHECK INTERMITTENT INCIDENT
Refer to EC-854, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Water should not exist.
Page 2454 of 4731
![INFINITI FX35 2005 Service Manual DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC P0442 EVAP CONTROL SYSTEMPFP:14950
On Board Diagnosis LogicABS007NV
This diagnosi INFINITI FX35 2005 Service Manual DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC P0442 EVAP CONTROL SYSTEMPFP:14950
On Board Diagnosis LogicABS007NV
This diagnosi](/img/42/57020/w960_57020-2453.png)
DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC P0442 EVAP CONTROL SYSTEMPFP:14950
On Board Diagnosis LogicABS007NV
This diagnosis detects leaks in the EVAP purge line using engine intake manifold vacuum.
If pressure does not increase, the ECM will check for leaks in the line between the fuel tank and EVAP canister
purge volume control solenoid valve, under the following “Vacuum test” conditions.
The EVAP canister vent control valve is closed to shut the EVAP purge line off. The EVAP canister purge vol-
ume control solenoid valve will then be opened to depressurize the EVAP purge line using intake manifold
vacuum. After this occurs, the EVAP canister purge volume control solenoid valve will be closed.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0442
0442 EVAP control system
small leak detected
(negative pressure) EVAP control system has a leak, EVAP
control system does not operate prop-
erly.
Incorrect fuel tank vacuum relief valve
Incorrect fuel filler cap used
Fuel filler cap remains open or fails to close.
Foreign matter caught in fuel filler cap.
Leak is in line between intake manifold and
EVAP canister purge volume control solenoid
valve.
Foreign matter caught in EVAP canister vent
control valve.
EVAP canister or fuel tank leaks
EVAP purge line (pipe and rubber tube) leaks
EVAP purge line rubber tube bent
Loose or disconnected rubber tube
EVAP canister vent control valve and the circuit
EVAP canister purge volume control solenoid
valve and the circuit
Fuel tank temperature sensor
O-ring of EVAP canister vent control valve is
missing or damaged
EVAP canister is saturated with water
EVAP control system pressure sensor
Fuel level sensor and the circuit
Refueling EVAP vapor cut valve
ORVR system leaks
PBIB1026E
Page 2459 of 4731
![INFINITI FX35 2005 Service Manual EC-1066
[VK45DE]
DTC P0442 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
9. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP contro INFINITI FX35 2005 Service Manual EC-1066
[VK45DE]
DTC P0442 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
9. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP contro](/img/42/57020/w960_57020-2458.png)
EC-1066
[VK45DE]
DTC P0442 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
9. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
2. Does water drain from the EVAP canister?
Ye s o r N o
Yes >> GO TO 10.
No (With CONSULT-II)>>GO TO 12.
No (Without CONSULT-II)>>GO TO 13.
10. CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).
OK or NG
OK (With CONSULT-II)>>GO TO 12.
OK (Without CONSULT-II)>>GO TO 13.
NG >> GO TO 11.
11 . DETECT MALFUNCTIONING PART
Check the following.
EVAP canister for damage
EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 15.
NG >> GO TO 14.
PBIB1031E
PBIB0147E