9. Release the parking brake.
10. Turn ON electric devices such as headlamps, A/C (set to the coldest temperature) and rear
window defogger to discharge the high voltage battery. Allow approximately 15 minutes to
discharge. Discharge is complete when the READY
indicator (B) (green) turns OFF and
the hybrid system warning indicator (C) (orange) turns ON.
11. Press the ignition switch (A) to turn the system OFF.
Please contact following number if the vehicle could not be discharged. • 1-800-662-6200 (US) or 1-800-361-4792 (Canada)
• Hours of operation are 8am-5pm (Monday-Friday) Eastern, Central and Pacific time zones.
3-4 How to Handle a Damaged Vehicle
3-4.1 High Voltage System Shut-Down Procedure
Any of the following procedures can shut down the high voltage system. The dismantling operation canonly
begin after shutting down the high voltage system. If the vehicle is heavily damaged, for example the high
voltage battery is deformed, broken or cracked, appropriate PPE must always be used and the high voltage
battery and high voltage components must not be touched.
DANGER
•Failure to properly shut down the high voltage system before the dismantling
procedures are performed will result in serious injury or death from electrical shock.
To prevent serious injury or death, NEVER touch high voltage harnesses or components
without always wearing appropriate Personal Protective Equipment (PPE) . PPE must
always be worn when touching or working on high voltage components.
•When contact with high voltage components or high voltage harnesses is
unavoidable, or when there is risk of such contact, you must always wear appropriate
PPE. PPE must always be worn when touching or working on high voltage components.
AAYIA0033ZZ
DG–19
Page 20 of 51

•The vehicle contains parts that contain powerful magnets. If a person who is
wearing a pacemaker or other medical device is close to these parts, the medical
device may be affected by the magnets. Such persons must not perform work on thevehicle.
• Be sure to check the READY indicator (1) in the instrument cluster, and verify that the READY indicator is off and the high voltage system is stopped.
• After the high voltage system is shut down, please wait for approximately ten (10) minutes for complete discharge of the high voltage capacitor. While waiting, do not
operate any vehicle functions.
• Remove the 12-volt battery negative (-) terminal and wait for three (3) minutes to discharge the air bag capacitor. Even though the 12-volt battery negative (-) is
disconnected, the Supplemental Restraint System (SRS) air bag maintains voltage for
three (3) minutes. There is a possibility of sudden SRS air bag inflation due to
harness short circuit or damage and it may cause serious injuries.
• The 12V system will remain active even after the 12-volt battery negative (-) terminal is removed while the high voltage system is active. This is because the DC/DC converter
will not shut down and power will be supplied to the 12V system and high voltage
system continuously.
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust the steering
column, adjust the seats, unlock the doors, open the trunk, etc. as required. Once the 12-volt battery is
disconnected, power controls will not operate.
Powering Down the High Voltage System
The high voltage system can be shut down with any 1 of the following procedures: • Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primary Procedure
(DG–21)
.
• Remove the fuse for the high voltage control system and disconnect the 12-volt battery. Refer to
Alternate Procedure 1 (Remove Fuses) (DG–23).
• Remove the service plug and disconnect the 12-volt battery. Refer to
Alternate Procedure 2
(Remove Service Plug) (DG–25)
.
DG–20
Page 21 of 51

Primary Procedure
NOTE:Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. Check the READY indicator (A) status in the instrument cluster. If it is on, the high voltage systemis active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch (B) once to turn OFF the high voltage system. Then verify whether the READY indicator (A) is off.
If the READY indicator (A) does not turn off, continue to the next steps to open the trunk for
12-volt battery negative cable access.
4.
If possible, keep the Infiniti Intelligent Key at least 5 meters
(16 feet) away from the vehicle (except as noted below) .
5. Open the trunk using any of the following: a. push-button switch (C) on the lower LH side ofthe instrument panel.
b. trunk button (D) on the Infiniti Intelligent Key [press for longer than one (1) second].
c. trunk open request switch (E) (located above license plate)*.
d. with the mechanical key (F) housed inside the Infiniti Intelligent Key.
Method Shift Selector Position Ignition Switch Status
a P or N Any
b P OFF
c* Any Any d Any Any
* You must have the Infiniti Intelligent Key within approximately 1 meter (3 feet) range of trunk request switch
to use the trunk open request switch function.
AAYIA0062ZZ
AAYIA0068ZZ
DG–21
Page 23 of 51

Alternate Procedure 1 (Remove Fuses)
NOTE:Before removing any fuses, if necessary, lower the windows, adjust the steering column,
adjust the seats, unlock the doors, etc. Once fuses are removed, power controls will notoperate.
1. Pull release handle (A) to open the hood.
2. Remove fuse box cover (B) .
3. Remove 80A fuse (C) (black) .
4. If you cannot identify the fuse (C) , remove all fuses in the fuse box.
To avoid unintended reinstallation and risk of electrical shock and severe personal
injury or death, the dismantler should carry the fuse or fuses on his/her person and cover
the fuse box with insulated tape.
A
A
B
BC80A Fuse (Black)
Front
AAYIA0125GB
DG–23
Page 25 of 51

Alternate Procedure 2 (Remove Service Plug)
DANGER
•Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the dismantler from serious injury or death
by electrical shock.
•
Immediately cover the service plug socket with insulated tape. The high voltage
battery retains high voltage power even when the service plug is removed. To avoid
electric shock, NEVER touch the terminals inside the socket.
To avoid unintended reinstallation and risk of electrical shock and severe personal injury
or death, the dismantler should carry the service plug on his/her person while work is in progress.
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. Check the READY indicator (A) status in the instrument cluster. If it is on, the high voltage systemis active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch (B) once to turn OFF the high voltage system. Then verify whether the READY indicator (A) is off.
If the READY indicator (A) does not turn off, continue to the next steps to open the trunk for
12-volt battery negative cable access.
AAYIA0062ZZ
DG–25