INFINITI QX4 2001 Factory Owners Manual
QX4 2001
INFINITI
INFINITI
https://www.carmanualsonline.info/img/42/57027/w960_57027-0.png
INFINITI QX4 2001 Factory Owners Manual
Page 770 of 2395
LEFT BANKNBEC0121S02
MEC948C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0134, P0154 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Wiring Diagram (Cont'd)
EC-235
Page 772 of 2395

3 CHECK HO2S1 (FRONT) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
MTBL0475
Continuity should exist.
3. Check harness continuity between ECM terminal or HO2S1 terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0476
Continuity should not exist.
4. Also check harness for short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
4 CHECK HO2S1 (FRONT) CONNECTOR FOR WATER
1. Disconnect heated oxygen sensor 1 (front) harness connector.
2. Check connectors for water.
Water should not exist.
OK or NG
OK (With CONSULT-II)©GO TO 5.
OK (Without CONSULT-
II)©GO TO 6.
NG©Repair or replace harness or connectors.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0134, P0154 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Diagnostic Procedure (Cont'd)
EC-237
Page 777 of 2395
Wiring DiagramNBEC0128RIGHT BANKNBEC0128S01
MEC949C
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Wiring Diagram
EC-242
Page 778 of 2395
LEFT BANKNBEC0128S02
MEC950C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Wiring Diagram (Cont'd)
EC-243
Page 780 of 2395

2 DETECT MALFUNCTIONING PART
Check the following.
IHarness connectors M32, F23
IFuse block (J/B) connector M10
I15A fuse
IHarness for open or short between heated oxygen sensor 1 (front) and fuse
©Repair harness or connectors.
3 CHECK HO2S1 (FRONT) OUTPUT CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
MTBL0520
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
4 CHECK HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between HO2S1 (front) terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 6.
NG©GO TO 5.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Diagnostic Procedure (Cont'd)
EC-245
Page 785 of 2395
Wiring Diagram=NBEC0136RIGHT BANKNBEC0136S01
MEC951C
DTC P0137, P0157 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MIN. VOLTAGE MONITORING)
Wiring Diagram
EC-250
Page 786 of 2395
LEFT BANKNBEC0136S02
MEC952C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0137, P0157 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MIN. VOLTAGE MONITORING)
Wiring Diagram (Cont'd)
EC-251
Page 788 of 2395
3 CHECK HO2S2 (REAR) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 2 (rear) harness protector color.
SEF372Z
3. Disconnect corresponding heated oxygen sensor 2 (rear) harness connector.
SEF971Y
4. Disconnect ECM harness connector.
5. Check harness continuity between ECM terminal and rear HO2S terminal as follows.
Refer to Wiring Diagram.
MTBL0521
Continuity should exist.
6. Check harness continuity between ECM terminal or HO2S2 terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0522
Continuity should not exist.
7. Also check harness for short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0137, P0157 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MIN. VOLTAGE MONITORING)
Diagnostic Procedure (Cont'd)
EC-253
Page 789 of 2395

4 CHECK HO2S2 (REAR) GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 4 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
2. Also check harness for short to power.
OK or NG
OK (With CONSULT-II)©GO TO 5.
OK (Without CONSULT-
II)©GO TO 6.
NG©Repair open circuit or short to power in harness or connectors.
5 CHECK HEATED OXYGEN SENSOR 2 (REAR)
With CONSULT-II
1. Start engine and drive vehicle at a speed of more than 70 km/h (43 MPH) for 2 consecutive minutes.
2. Stop vehicle with engine running.
3. Select ªFUEL INJECTIONº in ªACTIVE TESTº mode, and select ªHO2S2 (B1)/(B2)º as the monitor item with CONSULT-
II.
4. Check ªHO2S2 (B1)/(B2)º at idle speed when adjusting ªFUEL INJECTIONº to±25%.
SEF972Y
ªHO2S2 (B1)/(B2)º should be above 0.62V at least once when the ªFUEL INJECTIONº is +25%.
ªHO2S2 (B1)/(B2)º should be below 0.57V at least once when the ªFUEL INJECTIONº is þ25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0137, P0157 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MIN. VOLTAGE MONITORING)
Diagnostic Procedure (Cont'd)
EC-254
Page 795 of 2395
Wiring Diagram=NBEC0144RIGHT BANKNBEC0144S01
MEC951C
DTC P0138, P0158 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MAX. VOLTAGE MONITORING)
Wiring Diagram
EC-260