diagram INFINITI QX4 2001 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2001, Model line: QX4, Model: INFINITI QX4 2001Pages: 2395, PDF Size: 43.2 MB
Page 796 of 2395

LEFT BANKNBEC0144S02
MEC952C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0138, P0158 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MAX. VOLTAGE MONITORING)
Wiring Diagram (Cont'd)
EC-261
Page 798 of 2395

3 CHECK HO2S2 (REAR) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 2 (rear) harness protector color.
SEF372Z
3. Disconnect corresponding heated oxygen sensor 2 (rear) harness connector.
SEF971Y
4. Disconnect ECM harness connector.
5. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
MTBL0523
Continuity should exist.
6. Check harness continuity between ECM terminal or HO2S2 terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0524
Continuity should not exist.
7. Also check harness for short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0138, P0158 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MAX. VOLTAGE MONITORING)
Diagnostic Procedure (Cont'd)
EC-263
Page 799 of 2395

4 CHECK HO2S2 (REAR) GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 4 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
2. Also check harness for short to power.
OK or NG
OK (With CONSULT-II)©GO TO 5.
OK (Without CONSULT-
II)©GO TO 6.
NG©Repair open circuit or short to power in harness or connectors.
5 CHECK HEATED OXYGEN SENSOR 2 (REAR)
With CONSULT-II
1. Start engine and drive vehicle at a speed of more than 70 km/h (43 MPH) for 2 consecutive minutes.
2. Stop vehicle with engine running.
3. Select ªFUEL INJECTIONº in ªACTIVE TESTº mode, and select ªHO2S2 (B1)/(B2)º as the monitor item with CONSULT-
II.
4. Check ªHO2S2 (B1)/(B2)º at idle speed when adjusting ªFUEL INJECTIONº to±25%.
SEF972Y
ªHO2S2 (B1)/(B2)º should be above 0.62V at least once when the ªFUEL INJECTIONº is +25%.
ªHO2S2 (B1)/(B2)º should be below 0.57V at least once when the ªFUEL INJECTIONº is þ25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0138, P0158 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(MAX. VOLTAGE MONITORING)
Diagnostic Procedure (Cont'd)
EC-264
Page 805 of 2395

Wiring Diagram=NBEC0152RIGHT BANKNBEC0152S01
MEC951C
DTC P0139, P0159 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Wiring Diagram
EC-270
Page 806 of 2395

LEFT BANKNBEC0152S02
MEC952C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0139, P0159 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Wiring Diagram (Cont'd)
EC-271
Page 808 of 2395

3 CHECK HO2S2 (REAR) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 2 (rear) harness protector color.
SEF372Z
3. Disconnect corresponding heated oxygen sensor 2 (rear) harness connector.
SEF971Y
4. Disconnect ECM harness connector.
5. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
MTBL0525
Continuity should exist.
6. Check harness continuity between ECM terminal or HO2S2 terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0526
Continuity should not exist.
7. Also check harness for short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0139, P0159 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-273
Page 809 of 2395

4 CHECK HO2S2 (REAR) GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 4 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
2. Also check harness for short to power.
OK or NG
OK (With CONSULT-II)©GO TO 5.
OK (Without CONSULT-
II)©GO TO 6.
NG©Repair open circuit or short to power in harness or connectors
5 CHECK REAR HEATED OXYGEN SENSOR
With CONSULT-II
1. Start engine and drive vehicle at a speed of more than 70 km/h (43 MPH) for 2 consecutive minutes.
2. Stop vehicle with engine running.
3. Select ªFUEL INJECTIONº in ªACTIVE TESTº mode, and select ªHO2S2 (B1)/(B2)º as the monitor item with CONSULT-
II.
4. Check ªHO2S2 (B1)/(B2)º at idle speed when adjusting ªFUEL INJECTIONº to±25%.
SEF972Y
ªHO2S2 (B1)/(B2)º should be above 0.62V at least once when the ªFUEL INJECTIONº is +25%.
ªHO2S2 (B1)/(B2)º should be below 0.57V at least once when the ªFUEL INJECTIONº is þ25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0139, P0159 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-274
Page 815 of 2395

Wiring DiagramNBEC0160RIGHT BANKNBEC0160S01
MEC951C
DTC P0140, P0160 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Wiring Diagram
EC-280
Page 816 of 2395

LEFT BANKNBEC0160S02
MEC952C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0140, P0160 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Wiring Diagram (Cont'd)
EC-281
Page 818 of 2395

2 CHECK HO2S2 (REAR) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
MTBL0527
Continuity should exist.
2. Check harness continuity between ECM terminal or HO2S2 terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0528
Continuity should not exist.
3. Also check harness for short to power.
OK or NG
OK©GO TO 3.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
3 CHECK HO2S2 (REAR) GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 4 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
2. Also check harness for short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to power in harness or connectors.
4 CHECK HO2S2 (REAR) CONNECTORS FOR WATER
Check heated oxygen sensor connector 2 (rear) and harness connector for water.
Water should not exist.
OK or NG
OK (With CONSULT-II)©GO TO 5.
OK (Without CONSULT-
II)©GO TO 6.
NG©Repair or replace harness or connectors.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0140, P0160 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Diagnostic Procedure (Cont'd)
EC-283