ignition INFINITI QX56 2006 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2006, Model line: QX56, Model: INFINITI QX56 2006Pages: 3383, PDF Size: 51.76 MB
Page 482 of 3383

TROUBLE DIAGNOSISATC-81
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
6. CHECK FRONT AIR CONTROL FOR PBR POWER AND GROUND
1. Reconnect front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 2 and terminal 15.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. CHECK PBR REFERENCE VOLTAGE CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 2 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary.
8. CHECK PBR REFERENCE VOLTAGE AND GROUND CIRCUITS
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 2 and terminal 15.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. CHECK PBR REFERENCE VOLTAGE CIRCUIT FOR OPEN
1. Disconnect the air mix door motor (rear) harness connector.
2. Check continuity between air mix door motor (rear) harness con- nector B155 (B) terminal 3, 2 and front air control harness con-
nector M49 (A) terminal 2, 15.
OK or NG
OK >> Replace air mix door motor (rear). Refer to ATC-163,
"REAR AIR MIX DOOR MOTOR" .
NG >> Repair or replace harness as necessary.
Connector Te r m i n a l s
Voltage
(Approx.)
(+) (-)
Front air control: M49 2 15 5V
WJIA1729E
Continuity should not exist.
WJIA1730E
Continuity should exist.
WJIA1731E
2 - 3 : Continuity should exist.
15 - 2 : Continuity should exist.
WJIA1748E
Page 483 of 3383

ATC-82
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
10. CHECK PBR FEEDBACK VOLTAGE
1. Reconnect the front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M50 terminal 42 and ground while rotating temperature control dial
(rear) from maximum cold to maximum heat.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
11 . CHECK PBR FEEDBACK SIGNAL CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect front air control harness connector.
3. Check continuity between front air control harness connector M50 terminal 42 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary.
12. CHECK PBR FEEDBACK CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the air mix door motor (rear) harness connector and front air control harness connector.
3. Check continuity between air mix door motor (rear) harness con- nector B155 terminal 4 and front air control harness connector
M50 terminal 42.
OK or NG
OK >> Replace air mix door motor (rear). Refer to ATC-163,
"REAR AIR MIX DOOR MOTOR" .
NG >> Repair or replace harness as necessary. Voltage : Approx. 1V - 4.5V
LJIA0053E
Continuity should not exist.
WJIA1749E
Continuity should exist.
LJIA0054E
Page 486 of 3383

TROUBLE DIAGNOSISATC-85
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
COMPONENT DESCRIPTION
Intake door motor
The intake door motor is attached to the intake unit assembly. It
rotates so that air is drawn from inlets set by the front air control.
Motor rotation is conveyed to a lever which activates the intake door.
DIAGNOSTIC PROCEDURE FOR INTAKE DOOR MOTOR
1. CHECK FRONT AIR CONTROL FOR POWER AND GROUND
1. Turn ignition switch ON.
2. Check voltage between front air control harness connector M49 terminal 7 and terminal 8 while placing the HVAC system into
self-diagnostic mode.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. CHECK INTAKE DOOR MOTOR CIRCUITS FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 7, 8 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary.
WJIA0552E
Connector Terminals
Condition Voltage
(Approx.)
(+) (-)
Front air control: M49 7 8
Self-diagnostic
mode Battery
voltage
WJIA1757E
7 - Ground : Continuity should not exist.
8 - Ground : Continuity should not exist.
WJIA1758E
Page 487 of 3383

ATC-86
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
3. CHECK FRONT AIR CONTROL FOR GROUND AND POWER
1. Press the BACK button to back out of self-diagnostic mode.
2. Check voltage between front air control harness connector M49 terminal 7 and terminal 8 while placing the HVAC system into
self-diagnostic mode.
OK or NG
OK >> GO TO 4.
NG >> Replace front air control. Refer to ATC-144, "
FRONT AIR CONTROL" .
4. CHECK INTAKE DOOR MOTOR AND CIRCUITS FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 7 and terminal 8.
OK or NG
OK >> Replace intake door motor. Refer to ATC-160, "Removal
and Installation" .
NG >> GO TO 5.
5. CHECK INTAKE DOOR MOTOR CIRCUITS FOR OPEN
1. Disconnect the intake door motor harness connector.
2. Check continuity between front air control harness connector M49 terminal 7, 8 and the intake door motor harness connector
M58 terminal 1, 6.
OK or NG
OK >> Replace intake door motor. Refer to ATC-160, "Removal
and Installation" .
NG >> Repair or replace harness as necessary.
Connector Terminals
Condition Voltage
(Approx.)
(+) (-)
Front air control: M49 8 7 Self-diagnostic
mode Battery
voltage
WJIA1759E
Continuity should exist.
WJIA1760E
1 - 7 : Continuity should exist.
6 - 8 : Continuity should exist.
WJIA0591E
Page 490 of 3383

TROUBLE DIAGNOSISATC-89
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
DIAGNOSTIC PROCEDURE FOR DEFROSTER DOOR MOTOR
1. CHECK FRONT AIR CONTROL FOR POWER AND GROUND
1. Turn ignition switch ON.
2. Press the defroster switch ( ).
3. Check voltage between front air control harness connector M49 terminal 20 and terminal 19 and press the defroster switch ( )
again.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. CHECK DEFROSTER DOOR MOTOR CIRCUITS FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 19, 20 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary.
3. CHECK FRONT AIR CONTROL FOR GROUND AND POWER
1. Press the defroster switch ( ).
2. Check voltage between front air control harness connector M49 terminal 19 and terminal 20 and press the defroster switch ( )
again.
OK or NG
OK >> GO TO 4.
NG >> Replace front air control. Refer to ATC-144, "
FRONT AIR CONTROL" .
ConnectorTerminals
Condition Voltage
(Approx.)
(+) (-)
Front air control: M49 20 19 Press
defroster
switch Battery
voltage
WJIA1765E
19 - Ground : Continuity should not exist.
20 - Ground : Continuity should not exist.
WJIA1766E
Connector Terminals
Condition Voltage
(Approx.)
(+) (-)
Front air control: M49 19 20 Press
defroster switch Battery
voltage
WJIA1767E
Page 491 of 3383

ATC-90
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
4. CHECK DEFROSTER DOOR MOTOR AND CIRCUITS FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 19 and terminal 20.
OK or NG6
OK >> GO TO 6.
NG >> GO TO 5.
5. CHECK DEFROSTER DOOR MOTOR CIRCUITS FOR OPEN
1. Disconnect the defroster door motor harness connector.
2. Check continuity between front air control harness connector M49 terminal 19, 20 and the defroster door motor harness con-
nector M144 terminal 1, 6.
OK or NG
OK >> Replace defroster door motor. Refer to ATC-159,
"Removal and Installation" .
NG >> Repair or replace harness as necessary.
6. CHECK FRONT AIR CONTROL FOR PBR POWER AND GROUND
1. Reconnect front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 2 and terminal 15.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. CHECK PBR REFERENCE VOLTAGE CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 2 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary. Continuity should exist.
WJIA1773E
19 - 1
: Continuity should exist.
20 - 6 : Continuity should exist.
WJIA0553E
Connector Terminals
Voltage
(Approx.)
(+) (-)
Front air control: M49 2 15 5V
WJIA1729E
Continuity should not exist.
WJIA1730E
Page 492 of 3383

TROUBLE DIAGNOSISATC-91
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
8. CHECK PBR REFERENCE VOLTAGE AND GROUND CIRCUITS
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 2 and terminal 15.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. CHECK PBR REFERENCE VOLTAGE CIRCUIT FOR OPEN
1. Disconnect the defroster door motor harness connector.
2. Check continuity between defroster door motor harness connec- tor M144 (B) terminal 3, 2 and front air control harness connec-
tor M49 (A) terminal 2, 15.
OK or NG
OK >> Replace defroster door motor. Refer to ATC-159,
"Removal and Installation" .
NG >> Repair or replace harness as necessary.
10. CHECK PBR FEEDBACK VOLTAGE
1. Reconnect the front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 25 and ground while cycling defroster switch on and off.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
11 . CHECK PBR FEEDBACK SIGNAL CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 25 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary. Continuity should exist.
WJIA1731E
2 - 3
: Continuity should exist.
15 - 2 : Continuity should exist.
WJIA1777E
Voltage : Approx. 1V - 4.5V
WJIA1786E
Continuity should not exist.
WJIA1787E
Page 493 of 3383

ATC-92
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
12. CHECK PBR FEEDBACK CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the defroster door motor harness connector and front air control harness connector.
3. Check continuity between defroster door motor harness connec- tor M144 terminal 4 and front air control harness connector M49
terminal 25
OK or NG
OK >> Replace defroster door motor. Refer to ATC-159,
"Removal and Installation" .
NG >> Repair or replace harness as necessary. Continuity should exist.WJIA0558E
Page 497 of 3383
![INFINITI QX56 2006 Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE INFINITI QX56 2006 Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE](/img/42/57028/w960_57028-496.png)
ATC-96
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE LINK BOX" .
OK or NG
OK >> GO TO 2.
NG >> GO TO 10.
2. CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector.
3. Turn ignition switch ON.
4. Press the mode switch to select any mode except OFF.
5. Turn the front blower control dial to high.
6. Check voltage between front blower motor harness connector M62 terminal 2 and ground.
OK or NG
OK >> GO TO 12.
NG >> GO TO 3.
3. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor relay.
3. Check voltage between front blower motor relay harness con- nector M107 terminal 5 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK FRONT BLOWER MOTOR RELAY
Turn ignition switch OFF.
Refer to ATC-100, "
Front Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace front blower motor relay. Fuses are good.
2 - Ground
: Battery voltage.
WJIA1331E
5 - Ground: Battery voltage.
WJIA1886E
Page 498 of 3383

TROUBLE DIAGNOSISATC-97
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
5. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
Check continuity between front blower motor relay harness connec-
tor M107 terminal 3 and front blower motor harness connector M62
terminal 2.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK VARIABLE BLOWER CONTROL POWER SUPPLY CIRCUIT FOR OPEN
1. Disconnect variable blower control harness connector.
2. Check continuity between front blower motor relay harness con- nector M107 terminals 3 and variable blower control harness
connector M122 terminal 1.
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
7. CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1. Disconnect front air control connector.
2. Check continuity between front air control harness connector M49 terminal 13 and variable blower control harness connector
M122 terminal 2.
OK or NG
OK >> GO TO 8.
NG >> Repair harness or connector.
8. CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front blower motor relay harness con- nector M107 terminal 2 and ground.
OK or NG
OK >> GO TO 9.
NG >> Repair harness or connector. 3 - 2
: Continuity should exist.
WJIA1360E
3 - 1: Continuity should exist.
WJIA1361E
13 - 2: Continuity should exist.
WJIA1362E
2 - Ground: Battery voltage.
WJIA1363E