INFINITI QX56 2008 Factory Service Manual
Manufacturer: INFINITI, Model Year: 2008, Model line: QX56, Model: INFINITI QX56 2008Pages: 4083, PDF Size: 81.73 MB
Page 2871 of 4083

PWC-30
< COMPONENT DIAGNOSIS >
ENCODER
1. Disconnect rear power window control unit LH.
2. Check continuity between rear power window motor LH connec-tor D204 terminal 6 and rear power window control unit LH con-
nector D209 terminal 3.
OK or NG
OK >> Replace rear power window control unit LH.
NG >> Repair or replace harness.
7. CHECK REAR POWER WINDOW MO TOR LH LIMIT SWITCH SIGNAL
1. Turn ignition switch ON.
2. Check voltage between rear power window control unit LH con- nector and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 8
8. CHECK REAR POWER WINDOW SWITCH LH OUTPUT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between rear power window control unit LH har- ness connector D209 terminal 2 and ground.
OK or NG
OK >> GO TO 9
NG >> Replace rear power window control unit LH.
9. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear power window control unit LH.
3. Check continuity between rear power window control unit LH connector D209 terminal 2 and rear power window motor LH
connector D204 terminal 5.
OK or NG
OK >> Replace rear power window motor LH. Refer to GW-13,
"Removal and Installation".
NG >> Repair or replace harness.
REAR RH
6 - 3 : Continuity should exist.
LIIA1383E
ConnectorTe r m i n a l s
Condition Voltage (V)
(Approx.)
(+) (-)
D209 3 Ground Rear power window LH is be-
tween fully-open and just be-
fore fully-close
d position (ON) 0
Rear power window LH is be-
tween just before fully-closed
position and fully-closed posi-
tion (OFF) 5
LIIA2366E
2 - Ground
: Approx. 5V
LIIA2367E
2 - 5: Continuity should exist.
LIIA1385E
Revision: March 2010 2008 QX56
Page 2872 of 4083

ENCODERPWC-31
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
REAR RH : DescriptionINFOID:0000000001806215
Detects condition of the front power window motor LH operation and transmits to main power window and door
lock/unlock switch as pulse signal.
REAR RH : Component Function CheckINFOID:0000000001806217
1. CHECK ENCODER OPERATION
Does front door glass RH perform AUTO open/close operation normally when operating main power window
and door lock/unlock switch?
Is the inspection result normal?
YES >> Encoder operation is OK.
NO >> Refer to PWC-31, "
REAR RH : Diagnosis Procedure"
REAR RH : Diagnosis ProcedureINFOID:0000000001806218
Encoder Circuit Check
1. CHECK ENCODER SIGNAL
1. Turn ignition switch ON.
2. Check the signal between rear power window control unit RH connector D309 terminal 4 and ground with oscilloscope.
OK or NG
OK >> GO TO 2
NG >> Replace rear power window control unit RH.
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear power window control unit RH and rear power window motor RH.
3. Check continuity between rear power window control unit RH
connector D309 terminal 4 and rear power window motor RH
connector D304 terminal 3.
OK or NG
OK >> GO TO 3
NG >> Repair or replace harness.
3. CHECK REAR POWER WINDOW MOTOR RH POWER SUPPLY
Connec- tor Te r m i n a l s
Condition Signal
(+) (-)
D309 4 Ground Opening
LIIA2368E
OCC3383D
4 - 3 : Continuity should exist.
LIIA1389E
Revision: March 2010 2008 QX56
Page 2873 of 4083

PWC-32
< COMPONENT DIAGNOSIS >
ENCODER
1. Turn ignition switch OFF.
2. Disconnect rear power window motor RH.
3. Turn ignition switch ON.
4. Check voltage between rear power window motor RH connectorD304 terminal 4 and ground.
OK or NG
OK >> GO TO 5
NG >> GO TO 4
4. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear power window motor RH and rear power win- dow control unit RH.
3. Check continuity between rear power window motor RH connec- tor D304 (B) terminal 4 and rear power window control unit RH
connector D309 (A) terminal 5.
OK or NG
OK >> Replace rear power window switch RH. Refer to PWC-
117, "Removal and Installation".
NG >> Repair or replace harness.
5. CHECK ENCODER GROUND
1. Disconnect rear power window motor RH.
2. Check continuity between rear power window motor RH connec- tor D304 terminal 6 and ground.
OK or NG
OK >> GO TO 7
NG >> GO TO 6
6. CHECK ENCODER GROUND CIRCUIT
1. Disconnect rear power window control unit RH.
2. Check continuity between rear power window motor RH connec- tor D304 terminal 6 and rear power window control unit RH con-
nector D309 terminal 3.
OK or NG
OK >> Replace rear power window control unit RH.
NG >> Repair or replace harness.
7. CHECK REAR POWER WINDOW MOTOR RH LIMIT SWITCH SIGNAL
4 - Ground
: Approx. 10V
LIIA0378E
4 - 5: Continuity should exist.
LIIA2358E
6 - Ground: Continuity should exist.
LIIA0380E
6 - 3: Continuity should exist.
LIIA1383E
Revision: March 2010 2008 QX56
Page 2874 of 4083

ENCODERPWC-33
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
1. Turn ignition switch ON.
2. Check voltage between rear power window control unit RH con- nector and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 8
8. CHECK REAR POWER WINDOW SWITCH RH OUTPUT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between rear power window control unit RH har- ness connector D309 terminal 2 and ground.
OK or NG
OK >> GO TO 9
NG >> Replace rear power window control unit RH.
9. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear power window control unit RH.
3. Check continuity between rear power window control unit RH connector D309 terminal 2 and rear power window motor RH
connector D304 terminal 5.
OK or NG
OK >> Replace rear power window motor RH. Refer to GW-13,
"Removal and Installation".
NG >> Repair or replace harness.
Connector Te r m i n a l s
Condition Voltage (V)
(Approx.)
(+) (-)
D209 3 Ground Rear power window RH is be-
tween fully-open and just be-
fore fully-closed position (ON)
0
Rear power window RH is be-
tween just before fully-closed
position and fully-closed posi-
tion (OFF) 5
LIIA2366E
2 - Ground
: Approx. 5V
LIIA2367E
2 - 5 : Continuity should exist.
LIIA1385E
Revision: March 2010 2008 QX56
Page 2875 of 4083

PWC-34
< COMPONENT DIAGNOSIS >
DOOR SWITCH
DOOR SWITCH
DescriptionINFOID:0000000001735683
Detects door open/close condition and transmits the signal to BCM.
Component Function CheckINFOID:0000000001735684
1. CHECK FRONT DOOR SWITCH INPUT SIGNAL
Check (“DOOR SW-DR” and “DOOR SW-AS”) in “DATA MONITOR” mode with CONSULT-III. Refer to PWC-
10, "RETAINED PWR : CONSULT-III Function (BCM - RETAINED PWR)".
Is the inspection result normal?
YES >> Front door switch circuit is OK.
NO >> Refer to PWC-34, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001735685
1. CHECK FRONT DOOR SWITCH
Check voltage between BCM connector and ground.
Is the measurement value within the specification?
YES >> Replace BCM. Refer to BCS-55, "Removal and Installation".
NO >> GO TO 2
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and front door switch.
3. Check continuity between BCM connector and front door switch connector.
4. Check continuity between front door switch connector and ground.
Monitor item Condition
DOOR SW-DR OPEN
: ON
CLOSE : OFF
DOOR SW-AS OPEN
: ON
CLOSE : OFF
Te r m i n a l s
Door conditionVoltage (V)
(Approx.)
(+)
(–)
BCM
connector Te r m i n a l
M18 12 GroundFront door
RH OPEN
0
CLOSE Battery voltage
M19 47 Front door
LH OPEN
0
CLOSE Battery voltage
LIIA0946E
BCM connector Terminal Front door switch
connector Terminal Continuity
M18 12RH: B108
2Yes
M19 47LH: B8
LIIA0947E
Revision: March 2010 2008 QX56
Page 2876 of 4083

DOOR SWITCHPWC-35
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3. CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
Is the measurement value within the specification?
YES >> GO TO 4
NO >> Replace BCM. Refer to BCS-55, "
Removal and Installation".
4. CHECK FRONT DOOR SWITCH
Check front door switch.
Refer to PWC-35, "
Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI-38, "Intermittent Incident".
NO >> Replace front door switch.
Component InspectionINFOID:0000000001735686
1. CHECK FRONT DOOR SWITCH
Check front door switches.
Is the inspection result normal?
YES >> Front door switch is OK.
NO >> Replace front door switch.
Front door switch connector Te r m i n a l
GroundContinuity
B8 (LH) 2N o
B108 (RH)
Te r m i n a l
Voltage (V)
(Approx.)
(+)
(–)
BCM connector Terminal
M18 12
Ground Battery voltage
M19 47
LIIA0946E
Te r m i n a l
Door switch Continuity
Door switches
2 Ground part of
door switch Pressed
No
Released Yes
LIIA2377E
Revision: March 2010 2008 QX56
Page 2877 of 4083

PWC-36
< COMPONENT DIAGNOSIS >
DOOR KEY CYLINDER SWITCH
DOOR KEY CYLINDER SWITCH
DescriptionINFOID:0000000001735687
Main power window and door lock/unlock switch detects condition of the door key cylinder and transmits to
BCM as the LOCK or UNLOCK signals.
Component Function CheckINFOID:0000000001735688
1. CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL
Check (“KEY CYL LK-SW”, “KEY CYL UN-SW”) in “DAT A MONITOR” mode for “POWER DOOR LOCK SYS-
TEM” with CONSULT-III. Refer to DLK-51, "
INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLI-
GENT KEY)".
Is the inspection result normal?
YES >> Key cylinder switch is OK.
NO >> Refer to PWC-36, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001735689
1. CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/ unlock switch connector and ground.
Is the measurement value within the specification?
YES >> Replace main power window and door lock/unlock switch.
NO >> GO TO 2
2. CHECK DOOR KEY CYLINDER SIGNAL CIRCUIT
Monitor item Condition
KEY CYL LK-SW Lock
: ON
Neutral / Unlock : OFF
KEY CYL UN-SW Unlock
: ON
Neutral / Lock : OFF
Te r m i n a l s
Key positionVoltage (V)
(Approx.)
(+)
(–)
Main power window
and door lock/unlock switch connector Te r m i n a l
D7 4
Ground Lock
0
Neutral/Unlock 5
6 Unlock
0
Neutral/Lock 5
ALKIA0309ZZ
Revision: March 2010 2008 QX56
Page 2878 of 4083

DOOR KEY CYLINDER SWITCHPWC-37
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and front door lock assembly LH (key cylinder switch).
3. Check continuity between main power window and door lock/ unlock switch connector (A) and front door lock assembly LH
(key cylinder switch) connector (B).
4. Check continuity between main power window and door lock/unlock switch connector (A) and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3. CHECK DOOR KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between front door lock assembly LH (key cylinder
switch) connector and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4. CHECK DOOR KEY CYLINDER SWITCH
Check door key cylinder switch.
Refer to PWC-37, "
Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI-38, "Intermittent Incident".
NO >> Replace front door lock assembly LH (door key cylinder switch).
Component InspectionINFOID:0000000001735690
COMPONENT INSPECTION
1. CHECK DOOR KEY CYLINDER SWITCH
Main power window
and door lock/unlock switch connector Te r m i n a lFront door lock as-
sembly LH (key cylin-
der switch) connector Terminal Continuity
D7 (A) 4
D14 (B) 1
Ye s
66
Main power window and door lock/unlock switch connector Te r m i n a l
Ground Continuity
D7 (A) 4
No
6
ALKIA1025ZZ
Front door lock assembly LH (key
cylinder switch) connector Te r m i n a l
GroundContinuity
D14 5 Yes
LIIA1572E
Revision: March 2010 2008 QX56
Page 2879 of 4083

PWC-38
< COMPONENT DIAGNOSIS >
DOOR KEY CYLINDER SWITCH
Check front door lock assembly LH (key cylinder switch).
Is the inspection result normal?
YES >> Key cylinder switch is OK.
NO >> Replace front door lock assembly LH (key cylinder switch).
Te r m i n a lKey positionContinuity
Front door lock assembly LH
(key cylinder switch) connector
6 5 Unlock
Yes
Neutral/Lock No
1 Lock
Yes
Neutral/Unlock No
LIIA1573E
Revision: March 2010 2008 QX56
Page 2880 of 4083

POWER WINDOW SERIAL LINKPWC-39
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
POWER WINDOW SERIAL LINK
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH : DescriptionINFOID:0000000001735691
Main power window and door lock/unlock switch, power window and door lock/unlock switch RH and BCM
transmit and receive the signal by power window serial link.
The signal mentioned below is transmitted from BCM to main power window and door lock/unlock switch and
power window and door lock/unlock switch RH
• Keyless power window down signal
The signal mentioned below is transmitted from main pow er window and door lock/unlock switch to power win-
dow and door lock/unlock switch RH
• Front door window RH operation signal
• Power window control by key cylinder switch signal
• Power window lock switch signal
• Retained power operation signal
POWER WINDOW MAIN SWITCH : Component Function CheckINFOID:0000000001735692
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
Check (“CDL LOCK SW ”, “CDL UNLOCK SW”) in “D ATA MONITOR” mode for “POWER DOOR LOCK SYS-
TEM” with CONSULT-III. Refer to DLK-48, "
DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)".
Is the inspection result normal?
YES >> Power window serial link is OK.
NO >> Refer to PWC-39, "
POWER WINDOW MAIN SWITCH : Diagnosis Procedure".
POWER WINDOW MAIN SWITCH : Diagnosis ProcedureINFOID:0000000001735693
Power Window Serial Link Check
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
1. Remove Intelligent Key or ignition key, and close front door LH and RH.
2. Check signal between BCM connector and ground with oscillo- scope when door lock and unlock switch (LH and RH) is turned
to “LOCK” or “UNLOCK”.
3. Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch
(LH and RH) is turned to “LOCK” or “UNLOCK”.
Monitor item Condition
CDL LOCK SW LOCK
: ON
UNLOCK : OFF
CDL UNLOCK SW LOCK
: OFF
UNLOCK : ON
LIIA0391E
Revision: March 2010 2008 QX56