1-1.2 Interior
Interior
components referenced in this manual are as follows:
A. Assist charge gauge B. READY indicator (green) C. Energy flow display *1
D. Energy flow display *1 E. Liftgate switch F. Hood release handle
G. START/STOP switch and
ON indicator lamp (orange)
*1: This screen may not be displayed due to customer settings. Only one of these screens will display
energy flow depending on vehicle optional equipment. AAYIA0261ZZ
DG–7
Page 9 of 48

1-3 Warning and Indicator Lamp Information
1. Hybrid System Warning Lamp (Orange) 2. READY Indicator (Green)
3. Master Warning Lamp (Orange or Red) 4. Hybrid System Overheated Stop Vehicle Warning
(Vehicle Information Display) Lamp Name
Icon Description
READ
Y Indicator
(Green) This lamp is on when the high-voltage system is powered up
and
the vehicle is ready to drive.
Master Warning Lamp
(Orange or Red) This lamp is on when another warning lamp or message is
displayed
in the instrument cluster.
Hybrid System
Warning Lamp *1
(Orange) This lamp is on or blinking when:
•
Malfunction has occurred in the high-voltage system and/or
• High-voltage leak to vehicle chassis and/or
• Emergency shut-off system has been activated. The shut-off system activates in the following conditions:
–
Front and side collisions in which the air bags are deployed.
– Certain rear collisions.
– Certain high-voltage system malfunctions.
*1: When this lamp is ON, the READY Indicator will turn OFF. AAYIA0263ZZ
DG–9
Page 19 of 48

NOTE:
The
engine must not be running at this time. If the engine has restarted, repeat the
previous steps.
9. Release the parking brake.
10. Unbuckle the seat belt and open the driver door. The READY indicator should remain ON
and
the engine should not be running.
11.
Turn ON electric devices such as headlamps, A/C (set to the coldest temperature) and rear window
defogger to discharge the battery. Allow approximately 15 minutes to discharge. Discharge is
complete when the READY indicator (B) (green) turns OFF, the hybrid system warning
indicator
(C) (orange) turns ON and the message display indicates “Li-ion battery low”.
12. Press the ignition switch (A) to turn the system OFF.
Please contact following number if the vehicle could not be discharged. • 1-800-662-6200 (US) or 1-800-361-4792 (Canada)
• Hours of operation are 8am - 5pm (Monday-Friday) Eastern, Central and Pacific time zones. AAYIA0078GB
AAYIA0334ZZ
DG–19
Page 34 of 48

4. Jump Starting
T
o start the hybrid system with a booster battery, the instructions and precautions below must be followed. If done incorrectly, jump starting can lead to a 12-volt battery explosion, resulting in severe
personal
injury or death. It could also damage your vehicle.
Jump starting provides power to the 12-volt system to allow the electrical systems to operate. The electrical
systems must be operating to allow the high-voltage battery to be charged. Jump starting does not charge
the high-voltage battery.
Discharged 12-volt battery may cause the following issues: • The instrument cluster cannot be displayed while the ignition switch is turned ON. (The hybridsystem cannot start.)
• Headlamps, horn, etc. are weak. • To avoid electrical shock, the high-voltage battery CANNOT be jump started.
•
Explosive hydrogen gas is always present in the vicinity of the 12-volt battery. Keep all
sparks and flames away from the 12-volt battery. Make sure the vent tube is mounted.
• Do not allow battery fluid to come into contact with eyes, skin, clothing or painted surfaces. Battery fluid is a corrosive sulfuric acid solution that can cause severe burns.
If the fluid comes into contact with anything, immediately flush the contacted area
with water.
• The booster battery must be rated at 12-volts. Use of an improperly rated battery can damage the vehicle.
• Whenever working on or near a 12-volt battery, always wear suitable eye protectors (for example, goggles or industrial safety spectacles) and remove rings, metal bands, or any
other jewelry. Do not lean over the 12-volt battery when jump starting.
• Do not attempt to jump start a frozen battery. It could explode and cause serious injury.
• QX60 HYBRID is equipped with an automatic cooling fan. It could come on at any time. Keep hands and other objects away from it.
• Always follow the jump starting instructions below. Failure to do so could result in damage to the charging system and cause personal injury.
DG–34
Page 36 of 48

If the green READY light does not come on, press the START button to turn the
Hybrid
System OFF. Carefully disconnect the negative cable then the positive cable. It is
recommended the vehicle is taken to an INFINITI retailer for repair.
9. After the green READY light in the meter display comes ON, carefully disconnect the
negative
cable and then the positive cable.
10. Replace the vent caps (if so equipped) . Be sure to dispose of the cloth used to cover the vent holes as it may be contaminated with corrosive acid.
11. Reinstall the fuse box cover.
NOTE:
If it is not possible to turn the hybrid system ON by following this procedure, it is
recommended you contact an INFINITI retailer immediately.
4-2 Shift Selector Lever Lock Release
If the 12-volt battery is low or discharged, the selector lever cannot be moved from the Park (P) position. If a
booster battery is not available, the selector lever lock can be manually released. To manually release the
selector lever lock, perform the following procedure: 1. Push the ignition switch to the LOCK or OFF position.
2. Apply the parking brake.
3. Remove the shift lock cover using a suitable tool.
4. Push down the shift lock using a suitable tool as shownin the illustration.
5. Push the selector lever button and move the selector lever to the Neutral (N) position while holding down the
shift lock. AAYIA0487ZZ
DG–36