DTC Description Possible Causes Action P1230-14
Fuel Pump Low Speed
Malfunction (VLCM) -
Circuit short to ground
or open
High Side output not
driven - Diagnosis
feedback indicates
output is short to
ground, open circuit
Refer to the electrical circuit diagrams and check
fuel pump delivery module for short to ground, open
circuit P1230-93
Fuel Pump Low Speed
Malfunction (VLCM) - No
operation
High Side output not
driven - Diagnosis
feedback indicates
output is at open load
or short to power
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check
fuel pump delivery module for short to power, open
circuit P1346-11
Fuel Level Sensor B
Circuit - Circuit short to
ground
Fuel level sensor B
analogue input circuit -
short to ground
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check
fuel level sensor B analogue input circuit for short to
ground P1346-15
Fuel Level Sensor B
Circuit - Circuit short to
battery or open
Fuel level sensor B
analogue input circuit -
short to power, open
circuit
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check
fuel level sensor B analogue input circuit for short to
power, open circuit P1624-13
Anti-theft System -
Circuit open
Anti-theft signal circuit
from CJB - open circuit
Refer to the electrical circuit diagrams and check
anti-theft signal circuit from CJB for open circuit C111A-11
Right Stop Lamp -
Circuit short to ground
Right stomp lamp
control circuit - short to
ground
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check
right stomp lamp control circuit for short to ground C111A-12
Right Stop Lamp -
Circuit short to battery
Right stomp lamp
control circuit - short to
power
Refer to the electrical circuit diagrams and check
right stomp lamp control circuit for short to power C111A-13
Right Stop Lamp -
Circuit open
Right stomp lamp
control circuit - open
circuit
Refer to the electrical circuit diagrams and check
right stomp lamp control circuit for open circuit C111B-11
Left Stop Lamp - Circuit
short to ground
Left stomp lamp control
circuit - short to ground
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check left
stomp lamp control circuit for short to ground C111B-13
Left Stop Lamp - Circuit
open
Left stomp lamp control
circuit - open circuit
Refer to the electrical circuit diagrams and check left
stomp lamp control circuit for open circuit C1120-11
Reversing lamp - Circuit
short to ground
Reverse lamp control
circuit - short to ground
Carry out any pinpoint test associated with this DTC
using the manufacturer approved diagnostic system.
Refer to the electrical circuit diagrams and check
reverse lamp control circuit for short to ground C1120-12
Reversing lamp - Circuit
short to battery
Reverse lamp control
circuit - short to power
Refer to the electrical circuit diagrams and check
reverse lamp control circuit for short to power C1120-13
Reversing lamp - Circuit
open
Reverse lamp control
circuit - open circuit
Refer to the electrical circuit diagrams and check
reverse lamp control circuit for open circuit C1120-15
Reversing lamp - Circuit
short to battery or open
Reverse lamp control
circuit - short circuit to
power, open circuit, high
resistance
Refer to the electrical circuit diagrams and check
reverse lamp control circuit for short circuit to power,
open circuit, high resistance. Repair wiring harness
as required. Clear DTC and retest