01INTRODUCTION
8
INFORMATION JUMP STARTING
WARNING: Hydrogen and oxygen gases
are produced during normal battery
operation. This gas mixture can explode if
flames, sparks or lighted tobacco are brought
near battery. When charging or using a battery in
an enclosed space, always provide ventilation and
shield your eyes.
Keep out of reach of children. Batteries contain
sulphuric acid. Avoid contact with skin, eyes, or
clothing. Also, shield eyes when working near
battery to protect against possible splashing of
acid solution. In case of acid contact with skin,
eyes, or clothing, flush immediately with water for
a minimum of fifteen minutes. If acid is swallowed,
drink large quantities of milk or water, followed by
milk of magnesia, a beaten egg, or vegetable oil.
SEEK MEDICAL AID IMMEDIATELY.
To Jump Start - Negative Ground Battery
WARNING: To avoid any possibility of
injury use particular care when connecting
a booster battery to a discharged battery.
1.Position vehicles so that jump leads will reach,
ensuring that vehiclesDO NOT TOUCH,
alternatively a fully charged slave battery may be
positioned on floor adjacent to vehicle.
2.Ensuring that ignition and all electrical
accessories are switched off, that parking brake
is applied and neutral is selected, connect the
jump leads as follows;
A.Connect one end of first jumper cable to positive
(+) terminal of booster battery.
B.Connect other end of first jumper cable to positive
(+) terminal of discharged battery.
C.Connect one end of second jumper cable to
negative terminal of booster battery.
D.Connect other end of second jumper cable to a
good earth point on the disabled vehicle (eg. engine
front lifting eye, as shown in J6086),NOT TO
NEGATIVE TERMINAL OF DISCHARGED
BATTERY.Keep jumper lead away from moving
parts, pulleys, drive belts and fan blade assembly.
WARNING: Making final cable connection
could cause an electrical arc which if
made near battery could cause an
explosion.
3.If booster battery is installed in another vehicle,
start engine and allow to idle.
4.Start engine of vehicle with discharged battery,
following starting procedure in Owners' Manual.
CAUTION: If vehicle fails to start within a
maximum time of 12 seconds, switch
ignition off and investigate cause. Failing
to follow this instruction could result in
irrepairable damage to catalyst, if fitted.
5.Remove negative (-) jumper cable from the
engine and then terminal of booster battery.
6.Remove positive (+) jumper cable from positive
terminals of booster battery and discharged
battery.
Page 376 of 455
AIR CONDITIONING
1
ADJUSTMENT GENERAL PRECAUTIONS
The refrigerant used in the air conditioning system is
HFC (Hydrofluorocarbon) R134a.
WARNING: R134a is a hazardous liquid
and when handled incorrectly can cause
serious injury. Suitable protective clothing
must be worn when carrying out servicing
operations on the air conditioning system.
WARNING: R134a is odourless and
colourless. Do not handle or discharge in
an enclosed area, or in any area where the
vapour or liquid can come in contact with naked
flame or hot metal. R134a is not flammable, but
can form a highly toxic gas.
WARNING: Do not smoke or weld in areas
where R134a is in use. Inhalation of
concentrations of the vapour can cause
dizziness, disorientation. uncoordination,
narcosis, nausea or vomiting.
WARNING: Do not allow fluids other than
R134a or compressor lubricant to enter the
air conditioning system. Spontaneous
combustion may occur.
WARNING: R134a splashed on any part of
the body will cause immediate freezing of
that area. Also refrigerant cylinders and
replenishment trolleys when discharging will
freeze skin to them if contact is made.
WARNING: The refrigerant used in an air
conditioning system must be reclaimed in
accordance with the recommendations
given with a Refrigerant Recovery Recycling
Recharging Station.
NOTE: Suitable protective clothing
comprises: Wrap around safety glasses or
helmet, heatproof gloves, rubber apron or
waterproof overalls and rubber boots.REMEDIAL ACTIONS
1.If liquid R134a strikes the eye, do not rub it.
Gently run large quantities of eyewash over the
eye to raise the temperature. If eyewash is not
available cool, clean water may be used. Cover
eye with clean pad and seek immediate medical
attention.
2.If liquid R134a is splashed on the skin run large
quantities of water over the area as soon as
possible to raise the temperature. Carry out the
same actions if skin comes into contact with
discharging cylinders. Wrap affected parts in
blankets or similar material and seek immediate
medical attention.
3.If suspected of being overcome by inhalation of
R134a vapour seek fresh air. If unconscious
remove to fresh air. Apply artificial respiration
and/or oxygen and seek immediate medical
attention.
NOTE: Due to its low evaporating
temperature of -30°C, R134a should be
handled with care.
WARNING: Do not allow a refrigerant
container to be heated by a direct flame or
to be placed near any heating appliance. A
refrigerant container must not be heated above
50°C.
WARNING: Do not leave a container of
refrigerant without its cap fitted. Do not
transport a container of refrigerant that is
unrestrained, especially in the boot of a car.
Page 377 of 455
82AIR CONDITIONING
2
ADJUSTMENT SERVICING PRECAUTIONS
Care must be taken when handling refrigeration
system components. Units must not be lifted by their
hoses, pipes or capillary lines. Hoses and lines must
not be subjected to any twist or stress. Ensure that
hoses are positioned in their correct run before fully
tightening the couplings, and ensure that all clips and
supports are used. Torque wrenches of the correct
type must be used when tightening refrigerant
connections to the stated value. An additional spanner
must be used to hold the union to prevent twisting of
the pipe.
Before connecting any hose or pipe ensure that
refrigerant oil is applied to the seat of the new '0' ring
but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs on components must be left in
place until immediately prior to connection.
The receiver/drier contains desiccant which absorbs
moisture. It must be positively sealed at all times.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
Use alcohol and a clean cloth to clean dirty
connections.
Ensure that all new parts fitted are marked for use
withR134a.
Refrigerant oil
Use the approved refrigerant lubricating oil - Nippon
Denso ND-OIL 8.
CAUTION: Do not use any other type of
refrigerant oil.
Refrigerant oil easily absorbs water and must not be
stored for long periods. Do not pour unused oil back
into the container.
When renewing system components, add the
following quantities of refrigerant oil:
Condenser 40ml..........................................................
Evaporator 80ml..........................................................
Pipe or hose 20ml........................................................
Receiver/drier 20ml......................................................Total quantity of refrigerant oil in system = 140ml
A new compressor is sealed and pressurised with
Nitrogen gas, slowly release the sealing cap, gas
pressure should be heard to release as the seal is
broken.
NOTE: A new compressor should always
have its sealing caps in place and these
must not be removed until immediately
prior to fitting
A new compressor is supplied with an oil fill of 140ml.
A calculated quantity of oil must be drained from a
new compressor before fitting.
To calculate the quantity of oil to be drained:
1.Remove sealing plugs from the OLD
compressor.
2.Invert compressor and gravity drain oil into
measuring cylinder. Rotating the compressor
clutch plate will assist complete draining.
3.Note the quantity of oil drained (Yml).
4.Calculate the quantity (Qml) of oil to be drained
from the NEW compressor using the following
formula:
Xml - (Yml + 20ml) = Qml
Rapid refrigerant discharge
When the air conditioning system is involved in
accident damage and the circuit is punctured, the
refrigerant is discharged rapidly. The rapid discharge
of refrigerant will also result in the loss of most of the
oil from the system. The compressor must be
removed and all the remaining oil in the compressor
drained and refilled as follows:
1.Gravity drain all the oil, assist by rotating the
clutch plate (not the pulley).
2.Refill the compressor with 90ml of new
refrigerant oil.
3.Plug the inlet and outlet ports.
Servicing Equipment
The following equipment is required for full servicing
of the air conditioning system.
Recovery, recycling and charging station
Leak detector
Thermometer +20°C to -60°C
Safety goggles and gloves
Page 378 of 455
AIR CONDITIONING
3
ADJUSTMENT REFRIGERANT RECOVERY, RECYCLING,
RECHARGING
WARNING: The air conditioning system is
charged with a high pressure, potentially
toxic refrigerant. Repairs or servicing must
only be carried out by an operator familiar with
both the vehicle system and the charging and
testing equipment.
All operations must be carried out in a
well-ventilated area away from open flame and
heat sources.
Always wear safety goggles and gloves when
opening refrigerant connections.
WARNING: Wear eye and hand safety
protection. Open connections slowly in
case liquid or pressure is present. Allow to
bleed off slowly.
CAUTION: Overcharging air conditioning
system will cause excessive head
pressure.
An air conditioning portable Refrigerant Recovery
Recycling Recharging Station for use with R134a
refrigerant incorporates all the features necessary to
recover refrigerant R134a from the air conditioning
system, to filter and remove moisture, to evacuate and
recharge with the reclaimed refrigerant. The unit can
also be used for performance testing and air
conditioning system analysis.
The operator must adhere to the equipment
manufacturers' instructions.
Recovery and recycling
1.Connect a Refrigerant Station to the high and
low pressure servicing connections.
2.Operate the refrigerant recovery system
according to the manufacturers instructions.
3.Measure the amount of oil discharged from the
system. Add an equal amount of new refrigerant
oil to compressor before evacuation sequence.
WARNING: Refrigerant must always be
recycled before reuse, to ensure that the
purity of the refrigerant is high enough for
safe use in the air conditioning system. Recycling
should always be carried out with equipment
which is design certified by Underwriter
Laboratory Inc. for compliance with SAE-J1991.
Other equipment may not recycle refrigerant to
the required level of purity.
A R134a Refrigerant Recovery Recycling
Recharging Station must not be used with any
other type of refrigerant.
Refrigerant R134a from domestic and commercial
sources must not be used in motor vehicle air
conditioning systems.
Evacuation and recharging
1.Add refrigerant oil to compressor if necessary.
2.Renew the receiver/drier.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using inert gas.
3.Connect a Refrigerant Station to the high and
low pressure servicing connections.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
4.Operate the refrigerant evacuation system
according to the manufactures instructions.
NOTE: If the vacuum reading is below
700mmHg after 15 minutes, suspect a leak
in the system. Partially recharge the
system and check for leaks using an electronic
leak tester. Check suction lines first, then run the
compressor for 5 minutes and then check the high
pressure lines.
CAUTION: The system must be Evacuated
immediately before recharging
commences. Delay between Evacuation
and Recharging is not permitted.
Page 379 of 455
82AIR CONDITIONING
4
ADJUSTMENT 5.Operate the refrigerant recharging system
according to the manufactures instructions.
Refrigerant to charge system is 1.1 kg.
6.If the full charge has not been accepted by the
system, start the engine and run it at 1500
rev/min for a minimum of 2 minutes.
Switch on the air conditioning system, open the
vehicle windows, set the temperature control to
cold and switch the blower to maximum speed.
7.Consult Refrigerant Station Manual for correct
procedure to complete the charge.
8.Carry out the air conditioning system
performance test.LEAK TEST SYSTEM
The following instructions refer to an electronic type
Refrigerant Leak Detector for use with R134a, which
is the safest and most sensitive.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using an inert gas (see below).
1.Place the vehicle in a well ventilated area but
free from draughts, as leakage from the system
could be dissipated without detection.
2.Follow the instructions issued by the
manufacturer of the particular leak detector
being used.
3.Commence searching for leaks by passing the
detector probe around all joints and components,
refrigerant gas is heavier than air.
4.Insert the probe into an air outlet of the
evaporator or into the evaporator drain tube.
Switch the air conditioning blower on and off at
intervals of ten seconds. Any leaking refrigerant
will be gathered in by the blower and detected.
5.Insert the probe between the magnetic clutch
and compressor to check the shaft seal for
leaks.
6.Check all service valve connections, valve plate,
head and base plate joints and back seal plate.
7.Check the condenser for leaks at the pipe
unions.
8.If any leaks are found, the system must be
discharged before rectification.
9.Rectify any leaks and recheck for leaks during
evacuation prior to charging.
Leak test using inert gas
Use Nitrogen or Helium gas.
1.Connect gas line to recharging station.
2.Pressurise system to 3 bar.
3.Carry out leak test as above.
Page 383 of 455
AIR CONDITIONING
1
REPAIR COMPRESSOR
Service repair no - 82.10.20
Remove
1.Disconnect battery.
2.Recover refrigerant from air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
3.Remove compressor drive belt.See
Compressor drive belt
4.Disconnect high pressure pipe from compressor.
5.Disconnect low pressure pipe from compressor.
6.Remove 'O' ring from each flange.
7.Disconnect compressor clutch harness
multi-plug.
8.Remove compressor from mounting bracket
studs.Refit
9.If a new compressor is to be fitted first drain oil
from new compressor. Drain and measure oil
from old compressor. Measure new oil equal to
amount from old compressor, add 30 ml extra to
this amount and refill new compressor through
outlet port.
10.Locate compressor over mounting bracket studs.
11.Reconnect compressor clutch harness
multi-plug.
12.Fit new 'O' rings to high and low pressure hose
flanges, lubricate with refrigerant oil.
13.Fit high and low pressure hoses.
14.Fit compressor drive belt
See Compressor
drive belt.
15.Evacuate and recharge air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
16.Reconnect battery.
17.Perform a leak test on disturbed joints.
18.Carry out a functional check.
Page 385 of 455
AIR CONDITIONING
3
REPAIR CONDENSER FAN AND MOTORS
Service repair no - 82.15.08
Remove
1.Disconnect battery.
2.Remove 6 screws and lift grille panel from
vehicle.
3.Disconnect fan motor multi-plugs and release
harness retaining clips.
4.Remove nut and washers and withdraw fan
blade from motor drive shaft.
5.Remove 2 retaining screws, release motor fan
from shroud support brackets and feed motor
multi-plug lead through appropriate aperture.
Refit
6.Feed motor lead through fan shroud.
7.Fit motor to fan shroud support brackets.
8.Reconnect fan lead multi-plug and secure with
retaining clips.
9.Fit fan blade to motor drive shaft.
10.Fit grille panel.
11.Reconnect battery.CONDENSER
Service repair no - 82.15.07
Remove
1.Disconnect battery.
2.Recover refrigerant from air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
3.Remove 6 screws and lift grille panel from
vehicle .
4.Disconnect condenser fan motor lead
multi-plugs.
5.Disconnect receiver/drier dual pressure switch
multi-plug.
6.Disconnect condenser low pressure pipe at
compressor.
7.Disconnect high pressure hose/pipe at
evaporator.
Page 386 of 455
82AIR CONDITIONING
4
REPAIR
8.Remove 4 bolts and large packing washers
securing fan cowling brackets to wing sides.
9.Remove 4 nuts securing fan cowling to lower
mounting bracket and lift complete assembly
from condenser.
10.Remove 2 bolts securing bonnet striker support
plate and cross braces to grille top panel.
11.Remove 2 bolts securing cross braces to front
wings.
12.Lift condenser, from bottom mounting lugs and
carefully ease forwards to clear top grille panel.
13.Lift condenser, complete with receiver/drier, from
vehicle taking care to clear high and low
pressure hose/pipes at side of radiator.
14.Disconnect condenser and receiver/drier pipes.
15.Remove clamp bolts and release receiver/drier if
a new condenser is to be fitted.
16.Discard all pipe connection 'O' rings. Cap or plug
all connections to prevent ingress of dirt and
moisture.Refit
17.Coat unions, threads and new 'O' rings with
refrigerant oil prior to reassembly.
18.Secure receiver/drier to mounting clamps.
19.Fit condenser and receiver/drier pipes.
20.Lower condenser into position ensuring high and
low pressure pipes are located between radiator
and front wing.
21.Secure cross braces and bonnet striker support
plate to top grille.
22.Secure cross braces to front wings.
23.Secure fan cowl assembly to lower mounting
bracket and front wings.
24.Fit high pressure pipe at evaporator.
25.Fit condenser low pressure pipe at compressor.
26.Connect multi-plug at receiver/drier dual
pressure switch.
27.Connect fan motor lead multi-plug.
28.Evacuate and recharge air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
29.Reconnect battery.
30.Fit grille panel.
Page 387 of 455
AIR CONDITIONING
5
REPAIR RECEIVER/DRIER
Service repair no - 82.17.01
Remove
1.Disconnect battery.
2.Recover refrigerant from air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
3.Remove 6 screws and lift grille panel from
vehicle.
4.Disconnect receiver/drier dual pressure switch
multi-plug.
5.Disconnect high pressure pipe at receiver/drier.
6.Disconnect bottom union at condenser.
7.Remove retaining bolts and open clamps.
8.Release receiver/drier from condenser and
discard. It is NOT recommended to refit old unit.
9.Discard all pipe connection 'O' rings. Cap or plug
all connections to prevent ingress of dirt and
moisture.
Refit
10.Coat unions, threads and new 'O' rings with
refrigerant oil prior to reassembly.
11.Secure new receiver/drier in retaining clamp.
12.Fit receiver/drier bottom union connector at
condenser.
13.Fit high pressure pipe to receiver/drier.
14.Fit pressure switch multi-plug.
15.Evacuate and recharge air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
16.Reconnect battery.
17.Fit grille panel assembly.HEATER/COOLER UNIT - LH DRIVE
Service repair no - 82.25.21
Remove
1.Disconnect battery.
2.Recover refrigerant from air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
3.Remove expansion tankSee COOLING
SYSTEM, Repair, Expansion tank
to gain
access to air conditioning high and low pressure
pipes.
4.Disconnect high and low pressure pipes. Discard
pipe connection 'O' rings. Cap or plug
connections to prevent ingress of dirt and
moisture.
5.Disconnect compressor clutch switch multi-plug.
6.Remove pipe connector from vacuum switch.
7.Remove retaining clip and disconnect control
cable from evaporator flap operating rod.
8.Remove screw and release outer cable retaining
bracket.
Page 388 of 455
82AIR CONDITIONING
6
REPAIR 9.Remove plug connector from resistor.
10.Remove relay from connecting block to gain
access to fixing screw.
11.Remove screw and release relay connector
block. Retain relay in connector block.
12.Remove screw and detach air conditioning 30
amp fuse bracket from resistor. Refit both
resistor retaining screws.
13.Using suitable pipe clamps, clamp heater matrix
feed and return hoses at base of heater/cooler
unit. Release retaining clips and remove hoses.
14.From inside vehicle remove front passenger
carpet, if fitted.
15.Remove retaining screws and fold back footwell
insulation.
16.Remove 2 bolts securing heater/cooler unit lower
mounting bracket to bulkhead.
17.From inside engine compartment remove 2 bolts
securing top heater/cooler unit mounting bracket
to engine bulkhead. This also releases earthing
leads.
18.Remove bolt securing support bracket to front of
heater/cooler casing.19.Lift heater/cooler unit clear of air duct seal and
remove from vehicle.
20.Discard all pipe connection 'O' rings.
Refit
21.Coat unions, threads and new 'O' rings with
refrigerant oil prior to reassembly.
22.Position heater/cooler unit in engine
compartment and locate with air duct seal.
23.Secure unit top and bottom mounting brackets to
bulkhead and support bracket to front of unit
casing. Fully tighten fixing bolts when unit is
correctly positioned.
24.Fit footwell insulation.
25.Reconnect heater matrix hoses.
26.Fit air conditioning fuse bracket, relay connector
block, relay and resistor plug connector.
27.Fit control cable to evaporator air flap operating
rod, using a new clip.
28.Fit pipe connector to vacuum switch.
29.Connect compressor clutch switch multi-plug.
30.Connect high and low pressure pipes to
evaporator.
31.Fit expansion tank
See COOLING SYSTEM,
Repair, Expansion tank.
32.Evacuate and recharge air conditioning system
See Adjustment, Refrigerant recovery,
recycling, recharging.
33.Reconnect battery.