coolant temperature MAZDA 626 1987 Service Manual
[x] Cancel search | Manufacturer: MAZDA, Model Year: 1987, Model line: 626, Model: MAZDA 626 1987Pages: 1865, PDF Size: 94.35 MB
Page 919 of 1865

TROUBLESHOOTING (G4A-HL) 7B
STEP 5 (ROAD TEST)
This step is performed to inspect for problems at the various ranges.
If
these tests show any problems,
adjust or replace by referring to the mechanical sections.
Perform the test at normal ATF operating temperature (50—80°C, 122—176°F).
D Range Test
Shift point, shift pattern, and shift shock
1. Shift the selector lever to D range and depress the OD OFF switch.
2. Accelerate the vehicle with half (4/8) and full (8/8) throttle valve opening.
3. Check that 1-2, 2-3 and 3-OD up-shifts and downshifts and lock-up are obtained. The shift points
must be as shown in the D range shift diagram.
Note
a) Vehicle speed on a chassis roller may not meet the specified shift diagram because of
tire size.
b) There is no lock-up or OD when the coolant temperature is below 72°C (162°F), and when
the OD OFF switch is depressed.
4. Check the up and down shifts for shift shock or slippage.
5. While driving in 3rd (50—60 km/h, 31—37 mph) shift the selector lever to 2 range and check that
3-2 downshift immediately occurs, then decelerate and check that engine braking effect is felt in
2nd gear.
D range shift diagram
FE engine
Caution
8/8 n
-OD
0 20(12) 40(25) 60(37) 80(50) 100(63) 120(74) 140(87)
Vehicle speed km/h (mph)
76GC7B-057
7B—53
Page 1128 of 1865

7C TROUBLESHOOTING
STEP 2 (STALL TEST)
This step is performed to determine if there is slippage of the friction elements or malfunction of the
hydraulic components.
Preparation
Check the following items prior to testing:
1. Engine coolant, engine oil and ATF levels.
2. Warm the engine thoroughly to raise the ATF temperature to operating level (50—80°C, 122—176°F).
3. Set the parking brake and block the front and rear of the wheels.
Pull the parking brake Water temperature
ATF
7C—14
76G07C-024
Page 1830 of 1865

30 TECHNICAL DATA
3A. COOLING SYSTEM (GASOLINE)
Engine model F6, F8, FE SOHC
Item FE DOHC ECE, Hong Kong
Singapore Middle East General
Cooling method Water-cooled, forced circulation
Water pump
Type Centrifugal, timing belt driven
Impeller diameter mm (in) 70 (2.76)
Number
of
impeller blades 6
Speed ratio 1
:
1.00 1
:
1.05
Water seal type Unified mechanical seal
Thermostat
Type Wax, 2-stage Wax
Start
to
open °C (°F) Sub: 83.5-86.5 (182-188) Main: 86.5-89.5 (188-193) 86.5-89.5 (188-193) 80.5-83.5 (177-182)
Full open °C (°F) 100 (212) 95 (203)
Lift mm (in) Sub: 1.5 (0.06) min.
Main: 8.0 (0.31) min. 8.5 (0.33) min.
Radiator
Type Corrugated
fin
Cap opening valve pressure kPa (kg/cm2,
psi)
74-103 (0.75-1.05,
11
-15)
Cooling system pressure kPa (kg/cm2,
psi)
103 (1.05,
15)
Cooling fan
Type Electric
Capacity W MTX 80 Capacity W ATX 120
Current A MTX 5
6 7.6
Current A ATX
—
8.0-11.0
Number
of
blades 4
Outer diameter mm (in) MTX 320 (12.6) Outer diameter mm (in) ATX 340 (13.4)
Switching temperature OFF -
ON
°C(°F) 97 (207) 91 (196)
Coolant
Capacity liters (US qt, Imp
qt)
With heater 7.5 (7.9, 6.6) Capacity liters (US qt, Imp
qt)
Without heater 7.0 (7.4, 6.2)
Protection Mixture percentage (volume)
%
Specific gravity
of
mixture
at
20°C (68 °F) Antifreeze solution
Protection Water Solution
Specific gravity
of
mixture
at
20°C (68 °F) Antifreeze solution Above -16°C (3°F) 65 35 1.054
Above -26°C (-15°F) 55 45 1.066
Above -40 °C (—40°F) 45 55 1.078
30-16
Page 1831 of 1865

TECHNICAL DATA 30
3B. COOLING SYSTEM (DIESEL)
Item Engine model RF-CX, RF-N
Cooling method Water-cooled, forced circulation
Water pump
Type Centrifugal, timing belt driven
Water seal type Unified mechanical seal
Thermostat
Type Wax, two stage
Start
to
open °C (°F) Main valve:
86.5-89.5 (188-193)
78.5-
Sub valve: 81.5 (173-179)
Full open lift mm (in)/°C (°F) Main valve: 8.0 (0.31) Sub valve: 1.5 (0.06) min./100 (212) min./100 (212)
Radiator
Type Corrugated
fin
Cap opening valve pressure kPa (kg/cm2,
psi)
74—103 (0.75—1.05,
11
-15)
Cooling circuit checking pressure kPa (kg/cm2,
psi)
103 (1.05,
15)
Cooling fan
Type Electric
Number
of
blade 4
Outer diameter mm (in) 340 (13.4)
Switching temperature OFF -»
ON
°C (°F) 91 (196)
Voltage V 12
Capacity W-A 120-8.0-11.0
Coolant
Capacity liters (US qt, Imp
qt)
With heater 9.5 (10.0, 8.4) Capacity liters (US qt, Imp
qt)
Without heater 9.0 (9.5, 7.9)
Protection Mixture percentage (Volume) Specific gravity
of
mixture
at
20°C (68 °F) Antifreeze solution
Protection Water Solution
Specific gravity
of
mixture
at
20°C (68 °F) Antifreeze solution Above -16°C (3°F) 65 35 1.054
Above -26°C (-15°F) 55 45 1.066
Above -40°C (-40°F) 45 55 1.078
30-17