MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-121
If the passenger's door or driver's door are locked 
while the passenger's door is open and when the key 
is still in the ignition

Page 122 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-122
INSPECTION PROCEDURE C-1: Central Door Locking System: The Central Door Locking System 
does not Work at all.
NOTE: This troubleshooting proced

Page 123 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-123
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interf

Page 124 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-124
STEP 2. Check ETACS-ECU connector C-219 for loose, 
corroded or damaged terminals, or terminals pushed back 
in the connector.
Q: Is ETACS-ECU

Page 125 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-125
STEP 4. Check the wiring harness between ETACS-ECU 
connector C-219 (terminal 2) and fusible link (1).
NOTE: Also check junction block connecto

Page 126 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-126
STEP 5. Check ETACS-ECU connectors C-217 and front 
door lock actuator (RH) connector E-05 for loose, corroded 
or damaged terminals, or termin

Page 127 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-127
NOTE: Also check intermediate connector C-12 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the 
connector. If interm

Page 128 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-128
NOTE: Also check intermediate connector C-12 and junction 
block connector C-211 for loose, corroded, or damaged termi-
nals, or terminals push

Page 129 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-129
INSPECTION PROCEDURE C-2: Central Door Locking System: Some Doors do not Lock or Unlock.
.
CIRCUIT OPERATION
The ETACS-ECU operates the central

Page 130 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-130
.
TECHNICAL DESCRIPTION (COMMENT)
The wiring harness between the door lock actuator or 
the ETACS-ECU and the door lock actuator may be 
defect