lock MITSUBISHI 380 2005 Workshop Manual
[x] Cancel search | Manufacturer: MITSUBISHI, Model Year: 2005, Model line: 380, Model: MITSUBISHI 380 2005Pages: 1500, PDF Size: 47.87 MB
Page 332 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-332
NOTE: Also check junction block connector C-204 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-204 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between rear combination lamp
(LH) connector F-09 (terminal 5) and ETACS-ECU
connector C-219 (terminal 14) in good condition?
YES : Replace the rear combination lamp socket assembly
(LH). Verify that the turn-signal lamps illuminate
normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the turn-signal lamps illuminate normally.
STEP 32. Check rear combination lamp (RH) connector
F-03 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is rear combination lamp (RH) connector F-03 in good
condition?
YES : Go to Step 33.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2. Verify that the turn-signal lamps illuminate
normally.
STEP 33. Check the rear turn-signal lamp bulb (RH).
(1) Remove the rear turn-signal (RH) lamp bulb.
(2) Verify that the rear turn-signal lamp bulb (RH) is not
damaged or burned out.
Q: Is the rear turn-signal (RH) lamp bulb in good
condition?
YES : Go to Step 34.
NO : Replace the rear turn-signal (RH) lamp bulb. Verify
that the turn-signal lamps illuminate normally.
Page 335 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-335
NOTE: Also check junction block connector C-204 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-204 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between rear combination lamp
(RH) connector F-03 (terminal 5) and ETACS-ECU
connector C-219 (terminal 9) in good condition?
YES : Replace the rear combination lamp socket assembly
(RH). Verify that the turn-signal lamps illuminate
normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the turn-signal lamps illuminate normally.
INSPECTION PROCEDURE I-4: The turn-signal lamp indicator does not illuminate normally.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
At the same time that the turn-signal lamps are illu-
minated, the ETACS-ECU sends a signal to illumi-
nate the turn-signal lamp indicator via the CAN bus
line.
.
TECHNICAL DESCRIPTION (COMMENT)
If the turn-signal indicator does not illuminate nor-
mally, connector(s), wiring harness in the CAN bus
lines, the ETACS-ECU or the combination meter may
be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The combination meter may be defective
The ETACS-ECU may be defective
.
Page 336 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-336
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the turn-signal lamps.
When the column switch or the hazard warning lamp switch are
operated, check that the turn-signal lamps illuminate and go off
normally.
Q: Are the turn-signal lamps in good condition?
YES : Go to Step 2.
NO : First, repair the turn-signal lamp(s). Refer to
Inspection Procedure I-3 "One of the turn-signal
lamps does not illuminate P.54B-316."
STEP 2. Using Diagnostic Tool MB991958, diagnose the
CAN bus line.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect Diagnostic Tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis P.54C-15).
Page 337 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-337
STEP 3. Using Diagnostic Tool MB991958, read the
combination meter diagnostic trouble code.
Check whether the combination meter-related DTC is set.
(1) Turn the ignition switch to the "ON" position.
(2) Check whether a combination meter-related DTC is set.
(3) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the DTC set?
YES : Diagnose the combination meter. Refer to P.54A-48.
NO : Go to Step 4.
Page 341 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-341
STEP 2. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
Set each switch to the following condition before checking input
signal from the fog lamp switch:
Ignition switch: ON
Fog lamp switch: ON
NOTE: Turn the ignition switch to the "ON" position in order to
disable the headlamp automatic shutdown function.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Operate Diagnostic Tool MB991958 according to the
procedure below to display "F.FOG."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "LIGHTING."
g. Select "F.FOG."
(3) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the Diagnostic Tool MB991958 display the items
"IG SW (IG1)" and "F.FOG LAMP" as normal condition?
Normal conditions are displayed for all the items : Go to
St e p 3 .
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1) P.54B-408."
Normal condition is not displayed for "F.FOG LAMP" :
Refer to Inspection Procedure M-3 "ETACS-ECU
does not receive any signal from the fog lamp switch
P.54B-410." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) ON
ITEM 36 F.FOG LAMP ON
Page 352 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-352
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the fog lamps.
When the fog lamp switch is operated, check that the fog lamps
illuminate/go off normally.
Q: Are the fog lamps operating properly?
YES : Go to Step 2.
NO : First, repair the fog lamps. Refer to Inspection
Procedure J-3 "One of the fog lamps does not
illuminate P.54B-345."
STEP 2. Using Diagnostic Tool MB991958, diagnose the
CAN bus line.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect Diagnostic Tool MB991958. Refer to "How to
connect SWS monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis P.54C-15).
Page 353 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-353
STEP 3. Using Diagnostic Tool MB991958, read the
combination meter diagnostic trouble code.
(1) Check whether a combination meter-related DTC is set.
(2) Turn the ignition switch to the "ON" position.
Check whether the combination meter-related DTC is set.
(3) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the DTC set?
YES : Diagnose the combination meter. Refer to P.54A-48.
NO : Go to Step 4.
Page 355 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-355
54B
INTERIOR LAMP
GENERAL DESCRIPTION CONCERNING THE INTERIOR LAMPM1549021800236
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80The following ECUs affect the functions and control
of the interior lamps.
Interior lamp control function
The ETACS-ECU controls the interior lamps by turn-
ing them on and off in the following way:
When a door is opened with the ignition switch
off, the interior lamps up to a luminance of 100
percent. When a door is closed, the interior lamps
dims at a luminance of 65 percent, and goes off
30 seconds later. However if the ignition switch is
turned ON or if a door is locked while the interior
lamps is dimming, the dome lamp will go off at
that point.
When a door is opened with the ignition switch
ON, the interior lamps up at a luminance of 100
percent. When a door is closed, the interior lamps
go off.
When the ignition key is removed with all doors
closed, the interior lamps up at a luminance of
100 percent, and goes off 30 seconds later. How-
ever if the ignition key is inserted again or if a
door is locked while the interior lamps is lighting,
the interior lamps will go off at that point.
To check keyless entry operations more easily,
the interior lamps is flashed once when the doors
are locked. When the doors are unlocked, the
interior lamps at a luminance of 100 percent, and
go off 15 seconds later.
NOTE: The dimmer function can be customised on
vehicles equipped with a multi center display (middle
grade type). Refer to P.54B-486.
NOTE: The dotted lines indicate that lighting mode
when the ignition switch is turned ON, door is locked,
or any door is opened during the timer illumination
time. FUNCTION CONTROL ECU
Interior lamp control function ETACS-ECU
Interior lamp automatic-shutoff function ETACS-ECU
Ignition key hole illumination lamp function ETACS-ECU
Door ajar indicator ETACS-ECU
Seat belt indicator ETACS-ECU
Page 359 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-359
INSPECTION PROCEDURE K-1: Interior Light: The dome lamp do not illuminate and go out normally.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the dome lamp according
to the following signals:
Ignition switch (IG1): ON or OFF
Key reminder switch: ON or OFF
Door switches: ON or OFF
Driver’s door lock actuator switch: ON or OFF
Interior lamp loaded signal: ON
.
TECHNICAL DESCRIPTION (COMMENT)
If the dome lamp does not illuminate normally, a
burned-out dome lamp bulb, the input circuits from
the switches described in "CIRCUIT OPERATION",
the power supply line to the switches or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 361 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-361
STEP 1. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."