SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-307
STEP 2. Check the input signal by using "DATA LIST"
menu of the SWS monitor.
Check the input signals from the following switches:
Ignition switch: "ON" to "OFF"
Lighting switch: "TAIL" or "HEAD"
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "H/L AUTO-CUT."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "LIGHTING."
g. Select "H/L AUTO-CUT."
(4) Check that normal conditions are displayed for the items
described in the table below.
(5) When the driver's door is opened, check that normal
conditions are displayed for the items described in the table
below.
Q: Does the Diagnostic Tool MB991958 display the items
"TAILLAMP SW", "IG SW IG1", "FRONT DOOR SW" and
"H/L AUTO-CUT" as normal condition?
Normal conditions are displayed for all the items :
Replace the front-ECU. Verify that the headlamp
automatic shutdown function works normally.
Normal condition is not displayed for "TAILLAMP SW" :
Refer to Inspection Procedure M-5 "ETACS-ECU
does not receive any signal from the taillamp switch
P.54B-420."
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 01 TAILLAMP SW ON
ITEM 30 IG SW (IG1) OFF
ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 32 FRONT DOOR SW ON
ITEM 35 H/L AUTO-CUT ON
Page 355 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-355
54B
INTERIOR LAMP
GENERAL DESCRIPTION CONCERNING THE INTERIOR LAMPM1549021800236
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80The following ECUs affect the functions and control
of the interior lamps.
Interior lamp control function
The ETACS-ECU controls the interior lamps by turn-
ing them on and off in the following way:
When a door is opened with the ignition switch
off, the interior lamps up to a luminance of 100
percent. When a door is closed, the interior lamps
dims at a luminance of 65 percent, and goes off
30 seconds later. However if the ignition switch is
turned ON or if a door is locked while the interior
lamps is dimming, the dome lamp will go off at
that point.
When a door is opened with the ignition switch
ON, the interior lamps up at a luminance of 100
percent. When a door is closed, the interior lamps
go off.
When the ignition key is removed with all doors
closed, the interior lamps up at a luminance of
100 percent, and goes off 30 seconds later. How-
ever if the ignition key is inserted again or if a
door is locked while the interior lamps is lighting,
the interior lamps will go off at that point.
To check keyless entry operations more easily,
the interior lamps is flashed once when the doors
are locked. When the doors are unlocked, the
interior lamps at a luminance of 100 percent, and
go off 15 seconds later.
NOTE: The dimmer function can be customised on
vehicles equipped with a multi center display (middle
grade type). Refer to P.54B-486.
NOTE: The dotted lines indicate that lighting mode
when the ignition switch is turned ON, door is locked,
or any door is opened during the timer illumination
time. FUNCTION CONTROL ECU
Interior lamp control function ETACS-ECU
Interior lamp automatic-shutoff function ETACS-ECU
Ignition key hole illumination lamp function ETACS-ECU
Door ajar indicator ETACS-ECU
Seat belt indicator ETACS-ECU
Page 359 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-359
INSPECTION PROCEDURE K-1: Interior Light: The dome lamp do not illuminate and go out normally.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the dome lamp according
to the following signals:
Ignition switch (IG1): ON or OFF
Key reminder switch: ON or OFF
Door switches: ON or OFF
Driver’s door lock actuator switch: ON or OFF
Interior lamp loaded signal: ON
.
TECHNICAL DESCRIPTION (COMMENT)
If the dome lamp does not illuminate normally, a
burned-out dome lamp bulb, the input circuits from
the switches described in "CIRCUIT OPERATION",
the power supply line to the switches or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 366 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-366
INSPECTION PROCEDURE K-2: Interior Light: The front dome lamp, rear dome lamp or trunk lamp do
not illuminate or go out normally.
.
CIRCUIT OPERATION
The ETACS-ECU operates the dome lamp according
to the following signals:
Ignition switch (IG1): ON or OFF
Key reminder switch: ON or OFF
Door switches: ON or OFF
Trunk lid latch assembly: ON or OFF
Driver’s door lock actuator switch: LOCK or
UNLOCK
.
Page 377 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-377
CIRCUIT OPERATION
The ETACS-ECU operates the dome lamp dimming
function according to the input signals from the fol-
lowing switches:
Ignition switch (IG1): OFF
Key reminder switch: ON
Door switches: OFF
Driver's door lock actuator switch: LOCK or
UNLOCK
.
TECHNICAL DESCRIPTION (COMMENT)
If the dome lamps do not dim normally, the input cir-
cuits from the switches described in "CIRCUIT
OPERATION" or the ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the dome lamp.
If a door is opened while the dome lamp switch is at
"door-linked" position, the dome lamp should illuminate.
Q: Does the dome lamp illuminate normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure K-1 "The dome lamp
do not illuminate and go out normally P.54B-359."
STEP 2. Check the adjustment function.
Q: Has the dome lamp delay-off time been set to other than
"0 second" by the adjustment function?
YES : Go to Step 3.
NO : Set the dome lamp delay-off time to "0 second."
Page 381 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-381
INSPECTION PROCEDURE K-4: Interior Light: The ignition key hole illumination lamp does not
illuminate or go out normally.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
When the driver's door is opened with the ignition
switch at "ACC" position, the ETACS-ECU illumi-
nates the ignition key hole illumination lamp.
The ignition key hole illumination lamp goes out
in 30 seconds after the driver's door is closed.
The ignition key hole illumination lamp remains
illuminated for 30 seconds after the ignition key is
pulled out.
The ETACS-ECU operates the ignition key hole
illumination lamp according to the input signals
from the following switches:
Ignition switch (IG1): OFF
Key reminder switch: OFF
Interior lamp loaded signal: ON
Vehicle condition:
Ignition switch: "LOCK" (OFF) or "ACC" posi-
tion
Ignition key: Removed from the ignition key
cylinder
Driver’s door: Opened or closed
.
TECHNICAL DESCRIPTION (COMMENT)
If the ignition key hole illumination lamp does not illu-
minate, the input circuits from the switches described
in "CIRCUIT OPERATION", the key reminder switch
(ignition key hole illumination lamp bulb) or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 390 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-390
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the interior lamps.
If the interior lamp switch is moved to the "door interlock posi-
tion", the interior lamps should illuminate when either door is
opened.
Q: Do the interior lamp illuminate normally?
All the interior lamps illuminate normally. : Go to Step 2.
None of the interior lamps illuminate normally. : Refer to
Inspection Procedure K-1 "The dome lamp do not
illuminate and go out normally P.54B-359."
Some of the interior lamps do not illuminate normally. :
Refer to Inspection Procedure K-2 "The front dome
lamp, rear dome lamp or trunk lamp do not illuminate
or go out normally P.54B-366."
STEP 2. Check the adjustment function.
Q: Has a setting other than "No auto-shutoff" been
selected for the interior lamp automatic shutdown
function by the adjustment function?
YES : Go to Step 3.
NO : Set the interior lamp automatic shutdown function to
another setting other than "No auto-shutoff".
Page 414 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-414
CIRCUIT OPERATION
The ETACS-ECU operates the following functions or
systems according to signal from the front door
switches:
Light reminder tone alarm function
Door ajar warning buzzer
Forgotten key reminder
Power window timer function
Sunroof timer function
Keyless entry system
Timed locking mechanism
Headlamp automatic shutdown function
Dome lamp
Interior lamp automatic-shutdown function
Ignition key hole illumination lamp
Door-ajar indicator lamp
.
TECHNICAL DESCRIPTION (COMMENT)
If the signal is not normal, the functions or systems
described in "CIRCUIT OPERATION" do not work
normally. If the signal is not normal, the front door
switches or the ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The front door switches may be defective
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 415 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-415
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
STEP 1. Check the input signal (by using the pulse check
mode of the monitor).
Check the input signals from the front door switches.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect the diagnostic tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check that diagnostic tool MB991958 sounds.
Q: Does diagnostic tool MB991958 sound when each front
door is opened and closed?
When the front door (RH) is opened and closed,
diagnostic tool MB991958 does not sound. : Go to Step
2.
When the front door (LH) is opened and closed,
diagnostic tool MB991958 does not sound. : Go to Step
7.
When either front door is opened and closed, diagnostic
tool MB991958 sounds. : Replace the ETACS-ECU. If the
functions described in "CIRCUIT OPERATION" work
normally, the input signal from the front door switches
should be normal.
STEP 2. Check front door switch (RH) connector D-34 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is front door switch (RH) connector D-34 in good
condition?
YES : Go to Step 3.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2. If the functions described in "CIRCUIT
OPERATION" work normally, the input signal from the
front door switch (RH) should be normal.
Page 417 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-417
STEP 6. Check the wiring harness between front door
switch (RH) connector D-34 (terminal 1) and ETACS-ECU
connector C-219 (terminal 10).
NOTE: Also check junction block connector C-204 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-204 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between front door switch (RH)
connector D-34 (terminal 1) and ETACS-ECU connector
C-219 (terminal 10) in good condition?
YES : Replace the ETACS-ECU. If the functions described
in "CIRCUIT OPERATION" work normally, the input
signal from the front door switch (RH) should be
normal.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. If the
functions described in "CIRCUIT OPERATION" work
normally, the input signal from the front door switch
(RH) should be normal.