radiator cap NISSAN 350Z 2007 Z33 Automatic Air Conditioner Workshop Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2007, Model line: 350Z, Model: NISSAN 350Z 2007 Z33Pages: 142, PDF Size: 5.44 MB
Page 89 of 142
TROUBLE DIAGNOSIS
ATC-89
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
Insufficient HeatingNJS00017
SYMPTOM: Insufficient heating
INSPECTION FLOW
*1AT C - 5 3 , "Operational Check"*2ATC-46, "FUNCTION CONFIRMA-
TION PROCEDURE", see No. 1.*3ATC-46, "
FUNCTION CONFIRMA-
TION PROCEDURE", see No. 5 to 7.
*4AT C - 6 3 , "
Air Mix Door Motor Cir-
cuit"
*5ATC-46, "FUNCTION CONFIRMA-
TION PROCEDURE", see No. 9.*6ATC-56, "
LAN System Circuit"
*7AT C - 6 9 , "Blower Motor Circuit"*8ATC-63, "Air Mix Door Motor Circuit"*9EC-223, "DTC P0117, P0118 ECT
SENSOR"
*10CO-10, "Changing Engine Coolant"*11CO-15, "Checking Radiator Cap"
SJIA1131E
Page 133 of 142
REFRIGERANT LINES
ATC-133
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION:
Make sure liquid tank bracket is securely installed at protru-
sion of condenser.
Make sure liquid tank bracket does not move to a position
below center of liquid tank.
Replace O-rings of condenser pipe with new ones, and then
apply compressor oil to it when installing it.
When recharging refrigerant, check for leaks.
Removal and Installation of CondenserNJS00023
REMOVAL
1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Drain engine coolant. Refer to CO-10, "
Changing Engine Coolant" .
3. Remove cover for condenser mounting bolt.
4. Remove tower bar. Refer to FSU-20, "
TOWER BAR" .
5. Remove engine cover (1), (2). Refer to EM-17, "
INTAKE MANIFOLD COLLECTOR" .
6. Remove air cleaner case (LH) and air duct (LH). Refer to and EM-15, "
AIR CLEANER AND AIR DUCT" .
7. Remove radiator fan shroud after removing radiator upper hose.
8. Remove mounting bolt for condenser.
9. Remove mounting bolt (A) from high-pressure flexible hose
bracket (1).
10. Disconnect one-touch joint between high-pressure flexible hose
(1) and condenser with disconnector (SST: 9253089912).
CAUTION:
Cap or wrap the high-pressure flexible hose and condenser
with suitable material such as vinyl tape to avoid the entry
of air.
Disconnect one-touch joint between high-pressure pipe 1 (2)
and condenser with disconnector (SST: 9253089908).
CAUTION:
Cap or wrap the joint of high-pressure pipe 1 and con-
denser with suitable material such as vinyl tape to avoid the
entry of air.
RJIA1441E
SJIA0249E
PJIA0183E
PJIA0189E