oil temperature RENAULT SCENIC 2007 J84 / 2.G Automatic Transmission Siemens TA2005 Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2007, Model line: SCENIC, Model: RENAULT SCENIC 2007 J84 / 2.GPages: 139, PDF Size: 0.43 MB
Page 11 of 139
AUTOMATIC TRANSMISSION
Fault finding - System operation
23A
23A - 11V5 MR-372-J84-23A100$116.mif
SIEMENS TA2005
Vdiag No.: 14-18
COMPUTER INPUTS AND OUTPUTS
INPUTS OUTPUTS
Diagnostic socket
Automatic
transmission
computer
Solenoid valve control
+ battery feed
+ after ignition feed + warning lights display
Intersystem signals + diagnostic
socketIntersystem signal + diagnostic
socket
Driver actions (brake light switch,
gear selector, multifunction
switch)Gear lever lock
AUTO sensors (turbine speed, oil
pressure, oil temperature)Reversing lights
Earth
Wire connection
Multiplex connection
Page 14 of 139
Fault finding - Fault summary table23A
23A - 14V5 MR-372-J84-23A100$290.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Fault summary table
* All Mégane vehicles except ScénicTool faultAssociated
DTCDiagnostic tool title
DF003 0641Analogue sensor power supply
DF005 0840Oil pressure sensor circuit
DF009 0705Multifunction switch prohibited position
DF012 0657Solenoid valve supply
DF016 0795Lock-up solenoid valve circuit
DF017 2753Exchanger flow rate solenoid valve circuit
DF023 0710Gearbox oil temperature sensor circuit
DF029 0709Multifunction switch in unstable position
DF036 0775Pressure modulating solenoid valve circuit
*DF064 0814Display circuit
DF084 C001Multiplex network
DF085 0753EVS1 sequence solenoid valve circuit
DF086 0758EVS2 sequence solenoid valve circuit
DF087 0763EVS3 sequence solenoid valve circuit
DF088 0773EVS5 sequence solenoid valve circuit
DF089 0768EVS4 sequence solenoid valve circuit
DF093 0819Manual sequential controls circuit
DF095 1928Gear lever lock electromagnet circuit
DF105 0741Declutching function when stopping
DF109 D123Engine torque multiplex signal
DF112 2709EVS6 sequence solenoid valve circuit
DF113 0740Converter lockup servo control
DF131 0730Slippage
DF145 D12FInvalid pedal position multiplex signal
MR-372-J84-23A100$290.mif
Page 16 of 139
Fault finding - Interpretation of faults23A
23A-16V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
DF003
PRESENT
OR
STOREDANALOGUE SENSOR SUPPLY
1.DEF: Voltage outside permitted range of values
NOTESSpecial notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Customer complaint: deterioration in gear shift strategies.
Deal first with faults: DF005 Oil pressure sensor circuit and DF023 Gearbox oil temperature sensor circuit.
Disconnect the battery.
Check the condition and cleanliness of the modular connector connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●connection code 5U, between components 119 and 781,
●connection code 5V, between components 119 and 781,
●connection code 5BC, between components 119 and 754,
●connection code 5BB, between components 119 and 754.
Check the supply of the analogue sensors = 5 V.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF003/DP0TA2005_V18_DF003
MR-372-J84-23A100$348.mif
Page 24 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-24V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF023
PRESENT
OR
STOREDGEARBOX OIL TEMPERATURE SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5BC, between components 119 and 754,
●connection code 5BB, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5BC,
●connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the sensor or the wiring if the resistance is not between:
2360 Ω and 2660 Ω at 20˚C
290 Ω and 327 Ω at 80˚C
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF023/DP0TA2005_V18_DF023
Page 39 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-39V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF105
PRESENT
OR
STOREDDECLUTCHING WHEN STATIONARY FUNCTION
DEF: Signal outside upper limit
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present following a delay of 5 seconds, with the engine running,
the vehicle stationary with a gear engaged and a difference of more than 384 rpm
between the engine speed and the turbine speed.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Use the Mégane II or Scénic II wiring diagram Technical Note.
Check the oil level in the engine and gearbox.
Top up if necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-levels (for Mégane II) and
MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check the engine speed:
–Possible engine speed instability
–Deal with the faults displayed on the diagnostic tool for the injection computer.
Deal with the other faults first.
Check the turbine speed:
–Possible inconsistency with the turbine speed,
–Possible turbine sensor fault,
–Possible solenoid valve oil pressure fault.
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
–Warm engine with gearbox oil temperature between 65 and 90˚C.
–Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1Engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2Engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3Engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF105/DP0TA2005_V18_DF105
Page 43 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-43V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF113
PRESENT
OR
STOREDCONVERTER LOCK-UP SERVO CONTROL
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF177 Automatic transmission overheating.
–DF226 Automatic transmission internal pressure.
–DF244 Turbine speed sensor signal
Use the Mégane II or Scénic II wiring diagram Technical Note.
Check the quality and level of the gearbox oil (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the gearbox is not leaking oil.
Carry out the converter setting point test.
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
Warm engine with gearbox oil temperature between 65 and 90˚C.
Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF113/DP0TA2005_V18_DF113
Page 48 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-48V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF017 Exchanger flow solenoid valve circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF131 Slipping.
–DF226 Automatic transmission internal pressure.
–DF237 Invalid coolant temperature signal.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the water-oil exchanger is not blocked.
Measure the resistance of component 754 between the following connections:
●connection code 5BC,
●connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be between:
2660 Ω < R < 2360 Ω at 20˚C and 327 Ω < R < 290 Ω at 80˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF177/DP0TA2005_V18_DF177
Page 52 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-52V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF226
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION INTERNAL PRESSURE
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Sensor feeds.
–DF005 Oil pressure sensor circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF244 Turbine speed sensor signal
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check the gearbox oil grade and level (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scénic II)).
Check that the gearbox is not leaking oil
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II)).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
●Warm engine with gearbox oil temperature between 65 and 90˚C.
●Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating (e.g.:
air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF226/DP0TA2005_V18_DF226
Page 73 of 139
Fault finding - Conformity check23A
23A - 73V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Conformity check
MAIN SCREEN
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
2Turbine speedPR007:Turbine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
3Power supplyPR008:Computer feed
voltage10 V < X < 13 VIn the event of a
fault, consult the
interpretation of this
parameter.
4Gearbox oil
temperaturePR004:Gearbox oil
temperature- 40 ˚C < X < 140 ˚CIn the event of a
fault, consult the
interpretation of this
parameter.
5Coolant
temperaturePR001:Coolant
temperature- 40 ˚C < X < 120 ˚CIn the event of a
fault, consult the
interpretation of this
parameter.
6Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
DP0TA2005_V14_CCONF/DP0TA2005_V18_CCONF
MR-372-J84-23A100$464.mif
Page 80 of 139
AUTOMATIC TRANSMISSION
Fault finding - Conformity check
23A
23A - 80V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18
SUB-FUNCTION: PRESSURE REGULATION (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
6Difference
between
reference
pressure and oil
pressurePR146:Difference
between
reference and oil
pressureX = PR138 - PR003 None.
7Gearbox oil
temperaturePR004:Gearbox oil
temperature- 40 ˚C < X < 140 ˚CIf there is a fault,
refer to the
interpretation of this
parameter.
8Sequential
actuator controlAC024:Sequential
actuator controlCommand used to actuate
all the solenoid valves.In the event of a
fault, refer to the
interpretation of this
command.