wheel RENAULT SCENIC 2007 J84 / 2.G Electrical Equipment - Xenon Bulbs Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2007, Model line: SCENIC, Model: RENAULT SCENIC 2007 J84 / 2.GPages: 38, PDF Size: 0.12 MB
Page 10 of 38
80C-10V2 MR-372-J84-80C000$040.mif
80C
Program No.: V010
Vdiag No.: 05
AFTER REPAIRTurn on dipped-beam headlights.
Check that the system performs its initialisation to verify that the computer has no
faults.
Adjust the headlights manually.
CF001COMPUTER CALIBRATION
NOTESThis configuration enables the computer to store the vehicle's reference level.
Begin by configuring the vehicle type; then calibrate the vehicle level.
The vehicle must be stationary. Also, the front and rear sensor values must be within
the permissible range.
To calibrate the computer, proceed as follows:
–Check tyre pressure and adjust if faulty.
–Park the vehicle on a level horizontal surface.
–Make sure that the headlights have been properly adjusted manually.
–Position the vehicle with the wheels set straight ahead, engine switched off, driver behind the wheel and dipped
headlights on.
–Turn on the ignition and enter xenon bulbs fault finding mode.
–Select Configuration mode.
–Run configuration CF001.
–When calibration is complete, exit fault finding mode.
–Lock and unlock the vehicle doors with the card.
–The computer has now been calibrated.
–Check status LC010, which should indicate Completed.
LC010COMPUTER CALIBRATIONNot completed
Completed
The configuration reading LC010 can have either of two statuses:
–Not completed: The computer has not been calibrated, the vehicle's reference level is unknown, and the
maximum and minimum body height levels have not been programmed.
–Completed: The computer has been calibrated. Normal system operation. The sensor reference levels have
been programmed.
XENON BULBS
Fault finding – Configurations and programming
Page 29 of 38
80C-29
AFTER REPAIRCarry out another fault finding check on the system.
Clear the fault memory.
Deal with any other faults.
V2 MR-372-J84-80C000$080.mif
80C
Program No.: V010
Vdiag No.: 05
ET001COMPUTER CALIBRATIONNot completed
Completed
NOTESThere must be no present or stored faults.
Special notes: The vehicle must be stationary, parked on a level surface with a driver
behind the wheel and the fuel tank full.
Not completedStatus ET001 must indicate not done if the computer has not yet been calibrated
and the vehicle reference heights have not been programmed.
If status ET001 remains stuck on the "not done" status, run the full fault finding procedure
because a component may be defective.
CompletedStatus ET001 must indicate Done if the computer has been calibrated and the vehicle
reference heights have been programmed.
This is normal operation status.
LAD_V05_ET001
XENON BULBS
Fault finding – Interpretation of statuses