oil level RENAULT SCENIC 2008 J84 / 2.G Automatic Transmission Siemens TA2000 Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 128, PDF Size: 0.43 MB
Page 26 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-26V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF018
PRESENT
OR
STOREDCONVERTER LOCKUP SLIPPAGE
NOTESCarry out injection system fault finding and check that it is operating correctly.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit
–DF016 Converter lock-up solenoid valve circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF038: Turbine speed sensor circuit.
–DF049 Gearbox oil pressure regulation.
Conditions for applying the fault finding procedure to stored faults:
The fault is reported present after driving in fixed 3
rd gear with speed stabilisation for
more than 3 minutes.
To check that there are no faults with the converter lock-up solenoid valve, use the interpretation of fault
DF016 Converter lock-up solenoid valve circuit.
To check that there are no faults with the turbine speed sensor, apply the interpretation of fault DF038 Turbine
speed sensor circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the transmission is not leaking oil.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF018/DP0TA2000_V11_DF018/DP0TA2000_V15_DF018
Page 35 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-35V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF049
PRESENT
OR
STOREDGEARBOX OIL PRESSURE REGULATION
1.DEF : Pressure regulation
NOTESCarry out injection system fault finding and check that it is operating correctly.
If the following faults are present or stored, deal with them first:
–DF003 Sensor feeds.
–DF005 Oil pressure sensor circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF038: Turbine speed sensor circuit.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
To make sure there are no problems with the pressure lock-up solenoid valve, use the interpretation of fault DF036
Pressure regulating solenoid valve circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the gearbox is not leaking oil.
Carry out a conformity check to detect any possible faults.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF049/DP0TA2000_V11_DF049/DP0TA2000_V15_DF049
Page 61 of 128
AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 61V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15AUTOMATIC TRANSMISSION
Fault finding – Conformity check
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESRun fault finding on the injection system and make sure that it is working perfectly.
If the following faults are present or stored, deal with them first:
DF003 - DF005 - DF016 - DF017 - DF018 - DF020 - DF023 - DF024 - DF036 -
DF049 - DF131
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
To make sure that there are no faults with the gearbox oil temperature sensor, apply the interpretation of fault
DF023 Gearbox oil temperature sensor.
To make sure that there are no faults with the exchanger flow solenoid valve, apply the interpretation of fault DF017
Exchanger flow solenoid valve circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels (for
Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling for Scénic II)).
Check that the gearbox is not leaking oil.
Check that the water-oil exchanger is not blocked.
If the fault is still present, there is a definitely a mechanical or hydraulic fault.
Deal with the other faults then proceed with the conformity check.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF177/DP0TA2000_V11_DF177/DP0TA2000_V15_DF177
MR-372-J84-23A050$462.mif
Page 102 of 128
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 102V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR003
OIL PRESSURE
NOTESThere must be no present or stored faults.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer.
Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connections:
●Connection code 5U between components 119 and 781.
●Connection code 5W between components 119 and 781.
●Connection code 5V between components 119 and 781.
●Connection code 5AZ, between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Reconnect the modular connector.
Measure the resistance of component 781 between the following connections:
●Connection code 5U.
●Connection code 5W.
The value should be approximately 20 kΩ.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, replace the sensor.
Measure the resistance of component 754 between the following connections:
●Connection code 5AZ.
●Connection code 5BA.
The value should be approximately 1 Ω ± 0.2 Ω at 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the solenoid valve or the electric/hydraulic interface harness is damaged.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the gearbox is not leaking oil.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_PR003/DP0TA2000_V11_PR003 /DP0TA2000_V15_PR003
Page 107 of 128
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 107V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR128
ENGINE/TURBINE SPEED DIFFERENCE
NOTESThere must be no present or stored faults.
Check gearbox oil grade and level.
If an oil change or top-up is necessary see the Draining-Filling-Levels section of the Workshop Repair Manual.
Check that the gearbox is not leaking oil.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connections:
●Connection code 5DA between components 119 and 1017.
●Connection code 5DB between components 119 and 1017.
●Connection code 5BX between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 1017 between the following connections:
●Connection code 5DA.
●Connection code 5DB.
The value should be approximately 300 Ω ± 40 Ω at a temperature of approximately 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is not correct, either the sensor or the harness is damaged. Replace the faulty component.
Measure the resistance of component 754 between the following connections:
●Connection code 5BX.
●Connection code 5BA.
The value should be approximately 1 Ω ± 0.2 Ω at 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the solenoid valve or the electric/hydraulic interface harness is damaged.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_PR128/DP0TA2000_V11_PR128 /DP0TA2000_V15_PR128
Page 113 of 128
AUTOMATIC TRANSMISSION
Fault finding – Dealing with command modes23A
23A - 113V4 MR-372-J84-23A050$792.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
AC024
ACTUATOR SEQUENTIAL CONTROL
NOTESCheck the 20A permanent computer feed fuse marked 15 in the Protection and
Switching Unit. Check the cleanliness and condition of the connections.
Check the 5A after-ignition computer feed fuse marked 5H in the Protection and
Switching Unit.
Replace the fuses if necessary.
Check the cleanliness and condition of the connections.
Engine speed zero and gear lever in position P or N.
If the solenoid valves are not activated, check:
–the gearbox oil level,
–the cleanness and condition of the computer connector and modular connector,
Check the insulation, continuity and absence of interference resistance on the following connections:
●Connection code 5AU between components 119 and 754.
●Connection code 5AV between components 119 and 754.
●Connection code 5AW between components 119 and 754.
●Connection code 5AX between components 119 and 754.
●Connection code 5AY between components 119 and 754.
●Connection code 5DL between components 119 and 754.
●Connection code 5DM between components 119 and 754.
●Connection code 5BA between components 119 and 754.
●Connection code 5AZ, between components 119 and 754.
●Connection code 5DD between components 119 and 1019.
●Connection code 5DN between components 119 and 1019.
If the fault is still present, contact the Techline.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ACO24/DP0TA2000_V11_AC024 /DP0TA2000_V15_AC024
Page 117 of 128
AUTOMATIC TRANSMISSION
Fault finding – Fault Finding Chart23A
23A-117V4 MR-372-J84-23A050$924.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
Start with the ALP1 cycle
ALP3 Automatic transmission operating faults
NOTESOnly refer to Customer complaints after carrying out a complete fault finding
procedure with the diagnostic tool and the conformity check.
If the engine races when shifting from 1/2 when cold (automatic transmission oil
temperature lower than 15˚C), replace the pressure modulating solenoid valve
(EVM).
Use the diagnostic tool to check the
consistency between the display and the gear
lever positions (ignition on and engine
stopped).Adjust the control settings following the instructions
provided (see MR 370, Mechanical, 23 A,
Automatic Transmission, Automatic
transmission control unit (for Mégane II and
Scénic II)).
Are they consistent?
Check the oil level and the condition of the oil
(colour, odour, etc.).Replace the automatic transmission (see MR 364,
Mechanical, 23A, Automatic transmission,
Removal-Refitting (for Mégane II) and MR 370,
Mechanical, 23A, Automatic transmission,
Removal-Refitting (for Scénic II)). Does the condition of the oil suggest there
is an internal fault in the automatic
transmission?
With the engine stopped, check the line
pressure information provided by the pressure
sensor (PR003 Oil pressure).Replace the pressure sensor (see MR 364,
Mechanical, 23A, Automatic transmission,
Pressure sensor (for Mégane II) and MR 370,
Mechanical, 23A, Automatic transmission,
Pressure sensor (for Scénic II)). Is the value higher than 0.2 bar?
NO
YES
YES
NO
YES
NO
A
AFTER REPAIRCarry out a road test followed by a complete check with the diagnostic tool.
DP0TA2000_V10_ALP3/DP0TA2000_V11_ALP3/DP0TA2000_V15_ALP3
Page 118 of 128
AUTOMATIC TRANSMISSION
Fault finding – Fault Finding Chart23A
23A-118V4 MR-372-J84-23A050$924.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ALP3
CONTINUED 1
Check the oil level.
Check the oil pressure value using PR003 Oil pressure:
Warm engine with gearbox oil temperature between 65 and 90˚C.
Measure the line pressure under the 3 following conditions:
Important
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bars.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bars.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bars.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bars.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bars.
Do the recorded values correspond to the specified values?
Shift the gear lever into position D and monitor
PR007 Turbine speed when accelerating.Replace the pressure modulating solenoid valve and
the oil. Repeat the check after replacement.
If the fault is still present, replace the hydraulic
distributor and all the solenoid valves (see MR 364
Mechanical, 23A, Automatic transmission,
Hydraulic distributor (for Mégane II) and MR 370
Mechanical, 23A, Automatic transmission,
Hydraulic distributor (for Scénic II)).
Does the turbine speed change?
Replace the automatic transmission (see MR 364, Mechanical, 23A,
Automatic transmission, Removal-Refitting (for Mégane II) and
MR 370, Mechanical, 23A, Automatic transmission, Removal-Refitting
(for Scénic II)).
A
YESNO
NOYES
B
AFTER REPAIRCarry out a road test followed by a complete check with the diagnostic tool.
Page 123 of 128
AUTOMATIC TRANSMISSION
Fault finding – Fault Finding Chart23A
23A -123V4 MR-372-J84-23A050$924.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ALP7 Oil present under vehicle
NOTESOnly refer to Customer complaints after carrying out a complete fault finding
procedure with the diagnostic tool and the conformity check.
Check the colour of the oil under the vehicle to determine the source of the leak (automatic transmission fluid is
red).
Clean the engine and gearbox.
Check the oil level in the engine and gearbox.
Top up if necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-levels (for Mégane II) and
MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
If there is no gearbox leak, look for a leak in the engine compartment.
If the leak is from the gearbox side:
–Locate the source of the leak and carry out the necessary repairs.
–Replace any faulty parts.
–Check the oil level.
AFTER REPAIRCarry out a road test followed by a complete check with the diagnostic tool.
DP0TA2000_V10_ALP7/DP0TA2000_V11_ALP7/DP0TA2000_V15_ALP7