Fault finding - Interpretation of faults
LPN RADIO
Vdiag No.: C4
86A
DF056
PRESENT
OR
STOREDMICROPHONE
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
–the + after ignition feed is activated,
–the multimedia system has been switched on using the on/off button,
–the "hands-free" function has been activated.
Use the wiring diagrams Technical Note for Scénic II ph2, Espace IV ph2, Trafic II
ph2 or Kangoo 2.
Look for any damage to the wiring harness and check the condition and connection of the connectors for
components 261 and 789.
Manipulate the wiring harness in order to observe a change in the fault status (present → stored).
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connector(s), otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–connection code 107F,
–connection code 107G,
between components 261 and 789.
If the connection or connections are faulty and if there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, replace the microphone.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
LPN_VC4_DF056