check engine RENAULT SCENIC 2009 J84 / 2.G Engine And Peripherals EDC16 Repair Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 273
Page 107 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -107V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF118
PRESENT
OR
STOREDEGR SOLENOID VALVE SERVO-CONTROL
1.DEF : Insufficient EGR valve flow
2.DEF : Excessive EGR valve flow
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
–the engine is started
–a road test
Special notes:
If the fault is present the EGR function is disabled.
If 2.DEF is present,
–the level 1 warning light is lit,
–there is smoke coming from the exhaust.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Priority when dealing with a number of faults:
–DF272 EGR valve control circuit if it is present or stored.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check for continuity and the absence of interference resistance of the following connections:
Injection computer, brown 48-track connector B, track C2 Track 1 EGR valve connector
Injection computer brown 48-track connector B, track D2 Track 5 EGR valve connector
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit (pipes pierced or damaged) and that the clamps are properly
tightened.
Measure the resistance of the EGR valve motor between tracks 1 and 5.
If the resistance measured is not between 1 Ω < X < 400 Ω at 20˚C, replace the EGR valve.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reset programming and select EGR valve to reset the EGR valve offsets
(see Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF118
Page 108 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -108V3 MR-372-J84-13B250$405.mif
DF195
PRESENT
OR
STOREDENGINE SPEED/CAMSHAFT SENSOR CONSISTENCY
1.DEF : Inconsistency of the signal
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after an attempt to start.
Special notes:
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, start the engine and check that the fault does not reappear.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Check the engine speed sensor and camshaft sensor connectors.
Check the injection computer connections.
Repair if necessary.
With the connector disconnected, check the continuity and absence of interference resistance on the following
connections:
injection computer connector B, track A1 track 1 of the camshaft sensor
injection computer connector B, track D1 track 2 of the camshaft sensor
injection computer connector B, track B1 track 1 of the engine speed sensor
injection computer connector B, track C1 track 2 of the engine speed sensor
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF195EDC16
PROGRAM No.: C1
Vdiag No.: 51
Page 109 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -109V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF195
CONTINUED
With the ignition on and the camshaft sensor connected:
Use a voltmeter to measure the voltage between tracks 1 and 3 of the camshaft sensor:
The voltage displayed should be equal to the battery voltage 0.08 V)
–If the voltage is outside permitted tolerance values, take the measurement again on the connector, with the
camshaft sensor disconnected,
–If the voltage is still outside permitted tolerance values with the sensor disconnected.
Check for continuity and absence of interference resistance on the following connection:
Camshaft sensor, track 3 + after ignition feed after relay
–If the measured voltage is correct with the sensor disconnected,
Measure the resistance of the camshaft sensor between tracks 2 and 3.
Replace the sensor if its resistance is not 10,250 ± 500 Ω at 20˚C
Check that the engine speed sensor is correctly mounted and that the flywheel target is not damaged.
Check that the gap between the engine speed sensor and the flywheel is 0.5 to 1.8 mm.
Measure the resistance of the engine speed sensor between terminals A and B of its black connector.
If the winding resistance is not between 510 Ω and 850 Ω at an engine temperature of 20˚C, replace the engine
speed sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
Page 110 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-110V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF209
PRESENT
OR
STOREDEGR POSITION SENSOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Micro-breaks
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
–there is smoke coming from the exhaust,
–the EGR offset fault finding function is disabled,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
–DF012 Sensor supply voltage no. 2 if it is present or stored.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
CO.0
NOTESNone.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF209
Page 113 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-113V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF226
PRESENT
OR
STORED
DAMPER VALVE CIRCUIT
CC.1 : Short circuit to + 12 V
CC.0 : Short circuit to earth
CO : Open circuit
CC : Short circuit
1.DEF : Internal electronic fault
2.DEF : External fault finding
3.DEF : Values outside tolerances
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
–the engine is started,
–a road test,
–actuator command AC012 Damper valve;
–switching off the ignition and waiting for 1 minute.
Special notes:
If the fault is present:
–it is difficult or even impossible to start the vehicle,
–the engine stops noisily,
–the level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
CC.1
NOTESAfter any work is carried out on the damper valve, run SC036
Reinitialise programming and select Damper valve, then
switch off the ignition and wait 1 minute.
Check the damper valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation from the + 12 V feed of the following connection:
Earth Track 1 of the damper valve
Injection computer brown 48-track connector B, track J4 Track 3 of the damper valve
Injection computer brown 48-track connector B, track B2 Track 4 of the damper valve
Repair if necessary.
If the fault is still present, replace the damper valve.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF226
Page 119 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-119V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Interpretation of faults
DF276
PRESENT
INJECTOR CODE PROGRAMMING
1.DEF : Internal electronic fault when writing
2.DEF : No code in memory
NOTESCondition for applying fault finding ONLY to a present fault:
The fault is declared present after:
–reprogramming the injection computer,
–replacing and programming the injection computer.
Special notes:
If the fault is present:
–the engine speed is limited,
–the level 1 warning light is lit.
1.DEF
NOTESNone.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting for 1 minute and then re-establish dialogue,
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF276P
Page 120 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -120V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF276
CONTINUED
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed).
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 Use of Injector Codes becomes YES, fault DF276 Injector Code Programming
will be present, and the engine will operate in defect mode.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establish dialogue:
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
Page 121 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -121V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF532
PRESENT
OR
STOREDALTERNATOR CHARGE SIGNAL
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Above maximum threshold
2.DEF : Below minimum threshold
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
If the fault is present, the level 1 warning light comes on.
IMPORTANT
The fault can appear after the alternator has been saturated for too long.
For stored faults, clear the fault, switch off the ignition and wait for 1 minute before
carrying out a road test to confirm the fault before any operation.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, check the insulation and continuity on the following connection:
Injection computer, connector C, track A3Alternator, Track 2, black connector
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF532
Page 128 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -128V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF652
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–ignition is on (CC.0),
–following a road test, engine warm (CO.1).
Special notes:
If the fault is present:
–the EGR function is inhibited,
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
Priorities when dealing with a number of faults:
DF011 Sensor voltage supply no. 1
IMPORTANT
The turbine upstream temperature sensor only measures temperatures above
200˚C.
Check the condition of the turbine upstream temperature sensor connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 1589).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 120).
If one of the connectors is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF652
Page 130 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -130V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF778
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE CONTROL
1.DEF: Temperature measured too high
2.DEF: Parameter at max limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–the engine is started with a speed greater than 1750 rpm and a fuel flow greater than
30 mg/st,
–a road test.
Special notes:
If the fault is present:
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
Apply TEST 3 Turbocharged air inlet circuit check.
Check the turbine upstream temperature sensor connections.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF778