13B-243
MR-372-J84-13B200$612.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR073
AIR FLOWMETER FEED VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the air flowmeter feed voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on.
0.5 < PR073 < 1 V
Default value: 0 V.
In the event of a fault, refer to the interpretation of fault DF013 Sensor supply voltage no. 3.
Engine running, engine coolant temperature > 80°C.
1.5 V < PR073 < 2.5 V
Default value: 0 V.
In the event of a fault, refer to the interpretation of fault DF013 Sensor supply voltage no. 3.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR073/EDC16_V58_PR073/EDC16_V5C_PR073/EDC16_V18_PR073/EDC16_V1C_PR073/EDC16_V20_PR073
Page 244 of 365

13B-244
MR-372-J84-13B200$648.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of parameters
PR076
REFRIGERANT SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the refrigerant sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on.
The value should be between:
0 V < PR076 < 5 V
In the event of a fault test the multiplex network.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR076/EDC16_V58_PR076/EDC16_V5C_PR076/EDC16_V18_PR076/EDC16_V1C_PR076/EDC16_V20_PR076 EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
MR-372-J84-13B200$648.mif
Page 245 of 365

13B-245
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR077
EGR VALVE POSITION SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the EGR valve position sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on.
0.5 < PR077 < 1.5 V
Default value: 0 V.
In the event of a fault, refer to the interpretation of fault DF012 Sensor supply voltage no. 2.
Engine running, engine coolant temperature > 80°C.
1.5 V < PR077 < 2.5 V
Default value: 0 V.
In the event of a fault, refer to the interpretation of fault DF012 Sensor supply voltage no. 2.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR077/EDC16_V58_PR077/EDC16_V5C_PR077/EDC16_V18_PR077/EDC16_V1C_PR077/EDC16_V20_PR077
Page 246 of 365

13B-246
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR079
ATMOSPHERIC PRESSURE SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the atmospheric pressure sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant temperature
>80 °C.
3.80 V < PR079 < 4 V
In the event of a fault, refer to the interpretation of fault DF003 Atmospheric pressure sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR079/EDC16_V58_PR079/EDC16_V5C_PR079/EDC16_V18_PR079/EDC16_V1C_PR079/EDC16_V20_PR079
Page 247 of 365

13B-247
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR080
RAIL PRESSURE SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the rail pressure sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on.
0.5 V < PR080 < 1 V
Default value: 5 V
In the event of a fault, refer to the interpretation of fault DF013 Sensor supply voltage no. 3.
Engine running, engine coolant temperature > 80°C.
1 V < PR080 < 1.5 V
Default value: 5 V
In the event of a fault, refer to the interpretation of fault DF013 Sensor supply voltage no. 3.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR080/EDC16_V58_PR080/EDC16_V5C_PR080/EDC16_V18_PR080/EDC16_V1C_PR080/EDC16_V20_PR080
Page 248 of 365

13B-248
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR083
AIR TEMPERATURE SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the air temperature sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with the engine stopped and the ignition on, or with the engine running and the engine
coolant temperature > 80°C.
vdiag 50, 58, 5c:
1.90 V < PR083 < 2.90 V
Default value: 5 V
In the event of a fault, refer to the interpretation of fault DF039 Inlet air temperature sensor circuit.
vdiag 18, 1c, 20:
1.90 V < PR083 < 3.10 V.
Default value: 5 V.
In the event of a fault, refer to the interpretation of fault DF003 Atmospheric pressure sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR083/EDC16_V58_PR083/EDC16_V5C_PR083/EDC16_V18_PR083/EDC16_V1C_PR083/EDC16_V20_PR083
Page 249 of 365

13B-249
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR084
COOLANT TEMPERATURE SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the coolant temperature sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on.
The voltage should be between 3 V < PR084 < 4 V
Default value: 5 V
In the event of a fault, refer to the interpretation of DF001 Coolant temperature sensor circuit.
Engine running, engine coolant temperature > 80°C.
The voltage should be between 1 V < PR084 < 2 V
Default value: 5 V
In the event of a fault, refer to the interpretation of DF001 Coolant temperature sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR084/EDC16_V58_PR084/EDC16_V5C_PR084/EDC16_V18_PR084/EDC16_V1C_PR084/EDC16_V20_PR084
Page 254 of 365

13B-254
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR131
EGR AIR FLOW DIFFERENCE
PARAMETER
DEFINITIONThis parameter indicates the EGR air flow difference.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant temperature
>80 °C.
PR131 = PR146 Inlet air flow – PR171 Air flow setpoint for EGR.
The value must be very close to 0.
In the event of a fault, consult the interpretation of parameter DF056 Air flow sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR131/EDC16_V58_PR131/EDC16_V5C_PR131/EDC16_V18_PR131/EDC16_V1C_PR131/EDC16_V20_PR131
Page 255 of 365

13B-255
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR132
AIR FLOW
PARAMETER
DEFINITIONThis parameter indicates the inlet air flow in kg/h.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
No faults must be present.
Perform this fault finding procedure:
– after finding an inconsistency in the parameter,
– or after a customer complaint (lack of power, smoke etc.).
Conformity check with engine stopped and ignition on.
Indicates the inlet air flow in kg/h.
The value should be between:
0 kg/h < PR132 < 10 kg/h.
In the event of a fault, refer to the interpretation of DF056 Air flow sensor circuit.
Conformity check with engine running, engine coolant temperature > 80°C.
Indicates the inlet air flow in kg/h.
The value should be between:
Approximately 30 kg/h
In the event of a fault, refer to the interpretation of DF056 Air flow sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_PR132/EDC16_V58_PR132/EDC16_V5C_PR132/EDC16_V18_PR132/EDC16_V1C_PR132/EDC16_V20_PR132
Page 256 of 365

13B-256
MR-372-J84-13B200$648.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of parameters
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
PR132
CONTINUED
Sensor electrical conformity.
Test the air inlet circuit (from the air filter inlet to the inlet manifold tracts,
apply test 4 Turbocharged air inlet circuit check):
– air filter unit inlet not blocked and filter not clogged,
–visual inspection only, run test 4 Turbocharged air inlet circuit check for ALP2 Starting difficult or
impossible,
– oil vapour recirculation circuit connected correctly,
–absence of leaks or blockages in the low and high pressure air circuits: ducts, presence and tightness of the
mounting clips, mounting of the turbocharging pressure sensor, intercooler, etc.
– check that the damper valve is not jammed.
Carry out the necessary repairs.
Check the electrical conformity of the air flowmeter:
Check the + 5 V supply to the air flowmeter on connection 3KJ between components 120 and 799.
Check the + 12 V after relay supply to the air flowmeter on connection 3B between components 120 and 799.
Check the continuity and the absence of interference resistance on the following connections:
– connection code 3DV,
– connection code 3DW.
Between components 120 and 799.
If any of the connections are faulty and there is a repair method (see Technical Note 6015A, Electrical wiring
repair, Wiring: precautions for repairs), repair the wiring; otherwise replace the wiring.
With the flow meter connected, the vehicle ignition on and engine stopped:
Measure the voltage between connections 3DV and 3DW between components 120 and 799.
Replace the air flowmeter if its voltage is not approximately 0.5 V < PR073 Air flowmeter supply voltage < 0.7 V.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.