light RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Repair Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 365, PDF Size: 2.11 MB
Page 107 of 365

13B-107
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF118
PRESENT
OR
STOREDEGR SOLENOID VALVE SERVO-CONTROL
1.DEF: Insufficient EGR valve flow.
2.DEF: Excessive EGR valve flow.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present the EGR function is disabled.
If 1.DEF is present, the level 1 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priority when dealing with a number of faults:
–DF272 EGR valve control circuit if it is present or stored.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
If dealing with this fault requires the EGR valve to be replaced, run command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check for continuity and absence of interference resistance of the following connections:
- connection code 3VP,
- connection code 3VQ.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit, pierced or damaged pipes, and the tightness of the clips.
Measure the resistance of the EGR valve motor between connections 3VP and 3VQ.
Replace the EGR valve if the resistance displayed is not between 1 Ω < X < 400 Ω at 20°C.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets (see
Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF118/EDC16_V58_DF118/EDC16_V5C_DF118/EDC16_V18_DF118/EDC16_V1C_DF118/EDC16_V20_DF118
Page 110 of 365

13B-110
MR-372-J84-13B200$324.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF176
PRESENT
OR
STOREDLOW-SPEED FAN ASSEMBLY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– an attempted start, or with engine running,
– command AC038 Low-speed fan assembly relay is run.
Special notes:
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
CO
NOTESNone.
Check the + 12 V after relay supply to the relay mounting R09 on connection 3FB.
Check the condition of the connections and the correct operation of the running lights relay.R09
Replace it if necessary.
Check the continuity and absence of interference resistance on connection 3JN between components 120
and 597.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.0
NOTESNone.
Check the continuity and insulation to earth of connection 3FB between components 983 and 700.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF176/EDC16_V1C_DF176/EDC16_V20_DF176EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
Page 115 of 365

13B-115
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF209
PRESENT
OR
STOREDEGR POSITION SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Micro-breaks
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– there is smoke coming from the exhaust,
– the EGR offset fault finding function is disabled,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
–DF012 Sensor supply voltage no. 2 if it is present or stored.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
If dealing with this fault requires the EGR valve to be replaced, run command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
CO.0
NOTESNone
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation to earth of the following connections:
– connection code 3EL,
– connection code 3GC.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF209/EDC16_V58_DF209/EDC16_V5C_DF209/EDC16_V18_DF209/EDC16_V1C_DF209/EDC16_V20_DF209
Page 118 of 365

13B-118
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF226
PRESENT
OR
STORED
DAMPER VALVE CIRCUIT
CC.1:Short circuit to + 12 V
CC.0: Short circuit to earth
CO: Open circuit
CC: Short circuit
1.DEF: Internal electronic fault
2.DEF: External fault finding
3.DEF: Values outside tolerances
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test,
– actuator command AC012 Damper valve;
– the ignition is switched off for 1 minute.
Special notes:
If the fault is present:
– it is difficult or even impossible to start the vehicle,
– the engine stops noisily,
– the level 1 warning light is illuminated.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
Deal with fault DF046 "Battery voltage" first if it is present or stored.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
CC.1
NOTESAfter any work is carried out on the damper valve, run SC036
Reinitialise programming and select Damper valve, then
switch off the ignition and wait 1 minute.
Check the damper valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation from + 12 V of the following connections:
– connection code NT (Laguna II) or N (Scénic II and Mégane II) between component 1461 and chassis earth
NT or N.
– connection code 3VN,
– connection code 3VM.
between components 120 and 1461.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the damper valve.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF226/EDC16_V58_DF226/EDC16_V5C_DF226/EDC16_V18_DF226/EDC16_V1C_DF226/EDC16_V20_DF226
Page 128 of 365

13B-128
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUIT
1.DEF: Valve jammed open
2.DEF: Valve jammed closed
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special notes:
The EGR function is inhibited if several faults are present with DF226 Damper valve
circuit.
If 1.DEF is present:
– the level 1 warning light is lit,
– the vehicle performance is reduced,
– there is smoke coming from the exhaust.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
1.DEF
2.DEF
NOTESNone
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and absence of interference resistance of the following connections:
– connection code 3VP,
– connection code 3VQ.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit, pierced or damaged pipes, and the tightness of the clips.
Measure the resistance of the EGR valve motor between connections 3VP and 3VQ.
Replace the EGR valve if the resistance displayed is not between 1 Ω < X < 400 Ω at 20°C.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets (see
Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF272/EDC16_V58_DF272/EDC16_V5C_DF272/EDC16_V18_DF272/EDC16_V1C_DF272/EDC16_V20_DF272
Page 129 of 365

13B-129
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF276
PRESENT
INJECTOR CODE PROGRAMMING
1.DEF: Internal electronic fault when writing
2.DEF: No code stored
NOTESCondition for applying fault finding ONLY to a present fault:
The fault is declared present after:
– reprogramming the injection computer,
– replacing and programming the injection computer.
Special notes:
If the fault is present:
– the engine speed is limited,
– the level 1 warning light is illuminated.
1.DEF
NOTESNone
Enter the injector codes using command SC002 Enter injector codes (see Interpretation of commands).
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establishing dialogue.
Refer to the interpretation of command SC002 Enter injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed)
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 “Use of injector codes” becomes “YES”, fault DF276 is present and the engine
operates in defect mode.
Program the injector codes using command SC002 Enter injector codes (see Interpretation of commands).
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establishing dialogue, refer
to interpretation of command SC002 Enter injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF276/EDC16_V58_DF276/EDC16_V5C_DF276/EDC16_V18_DF276/EDC16_V1C_DF276/EDC16_V20_DF276
Page 130 of 365

13B-130
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF308
PRESENT
OR
STOREDCLOGGED PARTICLE FILTER
1.DEF: Maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the EGR function is inhibited,
– the vehicle performance is reduced,
– the level 1 warning light is illuminated and a warning message or a special particle
filter warning light is displayed on the instrument panel.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
– DF315 Particle filter differential pressure sensor if it is present.
– DF308 if DF315 is stored.
– DF226 Damper valve circuit if it is present or stored.
– DF272 EGR valve control circuit if it is present or stored.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF308/EDC16_V58_DF308/EDC16_V5C_DF308/EDC16_V18_DF308/EDC16_V1C_DF308/EDC16_V20_DF308
Page 136 of 365

13B-136
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
*temp: temperatureDF310
PRESENT
OR
STORED
PARTICLE FILTER UPSTREAM TEMP*. SENSOR
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to +12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present if:
– ignition is on (CC.0),
– following a road test, engine warm (CO.1).
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the level 1 warning light is lit,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
IMPORTANT
The particle filter upstream temperature sensor only measures temperatures
above 50°C.
CC.0
NOTESNone.
Check the condition of the particle filter upstream temperature sensor connector (see Wiring Diagram Technical
Note, Mégane II, Scénic II or Laguna II, component code 1287).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II or Laguna II, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation to earth of the following connections:
– connection code3XT,
– connection code3TD,
between components 120 and 1287.
If any of the connections are faulty and there is a repair method (see Technical Note 6015A, Electrical wiring
repair, Wiring: precautions for repairs), repair the wiring; otherwise replace the wiring.
If the fault is still present, replace the particle filter upstream temperature sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF310/EDC16_V58_DF310/EDC16_V5C_DF310/EDC16_V18_DF310/EDC16_V1C_DF310/EDC16_V20_DF310
Page 138 of 365

13B-138
MR-372-J84-13B200$360.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
*diff.: differential
*temp.: temperatureDF311
PRESENT
OR
STORED
FAILED REGENERATIONS LIMIT EXCEEDED
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– the level 1 warning light is lit,
– particle filter regenerations when driving are inhibited.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
– DF308 Particle filter clogged if it is present or stored,
– DF226 Damper valve circuit if it is present or stored,
– DF272 EGR valve control circuit if it is present or stored.
The fault appears after a certain number of failed regeneration attempts while driving (between 10 and 12
for MEGANE II and SCENIC II; between 6 and 8 for LAGUNA II).
–Run TEST 2 Air path at the turbocharger.
Check that there are no leaks or blockages in the exhaust pipe,
Repair if necessary
– Carry out an After-Sales regeneration.
– Follow the procedure for command SC017 Particle filter regeneration (see Interpretation of commands).
Carry out an oil change if the particle filter is replaced.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V58_DF311/EDC16_V5C_DF311/ EDC16_V1C_DF311/EDC16_V20_DF311EDC16
Program No.: C1
Vdiag No.: 1C, 20,
58, 5C
Page 139 of 365

13B-139
MR-372-J84-13B200$360.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF312
PRESENT
OR
STOREDSPEED REQUEST
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– a warning message or a special particle filter warning light is displayed on the
instrument panel,
– A specific kind of driving is required to bring about regeneration of the
particle filter when driving.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF308 Particle filter clogged if it is present or stored,
–DF311 Number of failed regenerations exceeded if it is present or stored,
– DF226 Damper valve circuit if it is present or stored,
–DF272 EGR valve control circuit if it is present or stored.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF312/EDC16_V58_DF312/EDC16_V5C_DF312/EDC16_V18_DF312/EDC16_V1C_DF312/EDC16_V20_DF312EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C