Page  70   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    –   uses a listening device, such as headphones or 
earphones that can be worn in or on or  
around the ears; and  
  –   has a player that can be body worn (of a size 
suitable to be carried in a clothing pocket) and  
i s intended for the user to walk around with while in 
continuous use (for example, on a street,  
in a subway, at an airport, etc.).  
 
EXAMPLES Portable CD players, MP3 audio players, mobile 
phones with MP3 type features, PDAs or similar equipment.  
 
Personal m usic players shall comply with the 
requirements of either 10.6.2 or 10.6.3.  
 
NOTE 1 Protection against acoustic energy sources from telecom 
applications is referenced to ITU - T P.360.  
 
NOTE 2 It is the intention of the Committee to allow the 
alternative met hods for now, but to only use the dose  
measurement method as given in 10.6.5 in future. Therefore, 
manufacturers are encouraged to implement 10.6.5 as soon as 
possible.  
 
Listening devices sold separately shall comply with 
the requirements of 10.6.6.  
These  requirements are valid for music or video 
mode only.  
The requirements do not apply to:  
–   professional equipment;  
 
NOTE 3 Professional equipment is equipment sold through 
special sales channels. All products sold through  
normal electronics stores are consid ered not to be professional 
equipment.  
 
–   hearing aid equipment and other devices for 
assistive listening;  
–   the following type of analogue personal music 
players:  
•  long distance radio receiver (for example, a 
multiband radio receiver or world band radio  
receiver, an AM radio receiver), and  
•  cassette player/recorder;  
 
NOTE 4 This exemption has been allowed because this 
technology is falling out of use and it is expected that  
within a few years it will no longer exist. This exemption will not 
be extended t o other technologies.  
 
–   a player while connected to an external amplifier 
that does not allow the user to walk around  
while in use.  
 
For equipment that is clearly designed or intended 
primarily for use by children, the limits of the  
relevant toy standards   may apply.  
 
The relevant requirements are given in    
Page 286 of 406

   
 
Page  73   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  known by other means such as setting or automatic 
detection, the  L Aeq , T  acoustic output shall be  ≤  80 dB 
when playing the fixed “programme simulation 
noise” described in EN 50332 - 1.  
–   for equipment provided with a standardized 
connector (for example, a 3,5 phone jack) that 
allows connection to a listening device for general 
use, the unweighted r.m.s. output voltage shall be  ≤ 
15 mV (analogue interface) or  - 30 dBFS (digital 
interface) w hen playing the fixed “programme 
simulation noise” described in EN 50332 - 1.  
10.6.3.3   RS2 limits (new)  
 
RS2 is a class 2 acoustic energy source that does 
not exceed the following:  
–   for equipment provided as a package (player with 
its listening device ), and with a proprietary connector 
between the player and its listening device, or where 
the combination of player and listening device is 
known by other means such as setting or automatic 
detection, the weekly sound exposure level, as 
described in EN 503 32 - 3, shall be  ≤  80 dB when 
playing the fixed "programme simulation noise" 
described in EN 50332 - 1.  
–   for equipment provided with a standardized 
connector (for example, a 3,5 phone jack) that 
allows connection to a listening device for general 
use, the unw eighted r.m.s. output level, integrated 
over one week, as described in EN50332 - 3, shall be 
≤  15 mV (analogue interface) or  - 30 dBFS (digital 
interface) when playing the fixed “programme 
simulation noise” described in EN 50332 - 1.     N/A  
10.6.4  
Requirements f or maximum sound exposure  
N/A  
10.6.4.1   Measurement methods  
 
All volume controls shall be turned to maximum 
during tests.  
 
Measurements shall be made in accordance with EN 
50332 - 1 or EN 50332 - 2 as applicable.     N/A  
10.6.4.2   Protection of persons  
 
Except as   given below, protection requirements for 
parts  accessible  to  ordinary persons ,  instructed 
persons  and  skilled persons  are given in 4.3.  
 
NOTE 1 Volume control is not considered a  safeguard.  
 
Between RS2 and an  ordinary person , the  basic 
safeguard  may be r eplaced by an  instructional 
safeguard  in accordance with Clause F.5, except 
that the  instructional safeguard  shall be placed on 
the equipment, or on the packaging, or in the 
instruction manual.     N/A   
Page 291 of 406

   
 
Page  78   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
5  
Modification to 4.Z1  
N /A  
4.Z1   Add  the following new subclause after 4.9:  
 
To protect against excessive current, short - circuits 
and earth faults in circuits connected to an a.c. 
mains , protective devices shall be included either as 
integral parts of the equipment or as parts of   the 
building installation, subject to the following, a), b) 
and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 
and B.4 shall be included as parts of the equipment;  
b) for components in series  with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short - circuit and earth 
fault protection may be provided by protective 
devices in the building installation;  
c) it is permitted for  pluggable equipm ent type B  or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in 
the building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instruc tions.  
 
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A  the 
building installation shall be regarded as providing 
protection in accordance with the ra ting of the wall 
socket outlet.     N/A  
6  
Modification to 5.4.2.3.2.4  
N/A  
5.4.2.3.2.4   Add  the following to the end of this subclause:  
 
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
7  
Modification to   10.2.1  
N/A  
10.2.1  
Add the following to  c)
  and  d)
  in table 39:  
 
For additional requirements, see 10.5.1.     N/A   
Page 295 of 406

   
 
Page  82   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
   
A   capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under  
the following conditions:  
 
•    the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
60384 - 14, which in addition to the Y3 tes ting, is 
tested with an impulse test of 2,5 kV defined in 
5.4.11;  
 
•   the additional testing shall be performed on all the 
test specimens as described in EN 60384 - 14;  
 
the impulse test of 2,5 kV is to be performed before 
the endurance test in EN 60384 - 14,   in the sequence 
of tests as described in EN 60384 - 14.  
5.5.2.1   Norway  
 
After the 3rd paragraph the following is added:  
 
Due to the IT power system used, capacitors are 
required to be rated for the applicable line - to - line 
voltage (230 V).     N/A  
5.5.6   Finland, Norway  and  Sweden  
 
To the end of the subclause the following is added:  
 
Resistors used as  basic safeguard  or bridging 
basic insulation  in  class I pluggable equipment 
type A  shall comply with G.10.1 and the test of 
G.10.2.     N/A  
5.6.1   Denmark  
 
Add  to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses  
with higher rating than the rating of the socket -
outlets the protection for pluggable  
equipment type A shall be an integral part of the 
equi pment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
 
After the indent for  pluggable equipment type A , 
the following is added:  
–   the  protective current rating  is taken t o be 13 A, 
this being the largest rating of fuse used in the 
mains  plug.     N/A   
Page 298 of 406

   
 
Page  85   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
 B.3.1 and  
B.4   Ireland and United Kingdom  
 
The following is applicable:  
 
To protect against exce ssive currents and short -
circuits in the primary circuit of  direct plug - in 
equipment , tests according to Annexes B.3.1 and 
B.4 shall be conducted using an external miniature 
circuit breaker complying with EN 60898 - 1, Type B, 
rated 32A. If the equipment doe s not pass these 
tests, suitable protective devices shall be included 
as an integral part of the  direct plug - in equipment , 
until the requirements of Annexes B.3.1 and B.4 are 
met     N/A  
G.4.2   Denmark  
 
To the end of the subclause the following is added:  
 
Sup ply cords of single phase appliances having a 
rated current not exceeding 13 A shall be provided 
with a plug according to DS 60884 - 2 - D1:2011.  
 
CLASS I EQUIPMENT provided with socket - outlets 
with earth contacts or which are intended to be used 
in locations  where protection against indirect contact 
is required according to the wiring rules shall be 
provided with a plug in accordance with standard 
sheet DK 2 - 1a or DK 2 - 5a.  
 
If a single - phase equipment having a RATED 
CURRENT exceeding 13 A or if a polyphase  
equ ipment is provided with a supply cord with a 
plug, this plug shall be in accordance with the 
standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 
60309 - 2.  
 
Mains socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A shal l 
be in accordance DS 60884 - 2 - D1:2011 standard 
sheet DKA 1 - 4a.  
 
Other current rating socket outlets shall be in 
compliance with Standard Sheet DKA 1 - 3a  
or DKA 1 - 1c.  
 
Mains socket - outlets with earth shall be in 
compliance with DS 60884 - 2 - D1:2011  
Standard Sh eet DK 1 - 3a, DK 1 - 1c, DK1 - 1d, DK 1 - 5a 
or DK 1 - 7a  
 
Justification:  
Heavy Current Regulations, Section 6c     N/A   
Page 317 of 406

   
 
Page  6   of  88   Report No. :  60404490 001  
 
 
TR F No.  IEC62368_1 C    
  
T est item particulars :  
CAR  AUDIO  
Product group    ................................ ..................... :     end product       built - in component  
Classification of use by   ................................ ....... :     Ordinary person       Children likely present  
  Instructed person  
  Skilled person  
Supply  c onnection   ................................ ............... :     AC  mains       DC mains  
  not mains connected :  
    ES1     ES2     ES3   
Supply  t olerance    ................................ ................. :     +10%/ - 10%   
  +20%/ - 15%   
  +           %/  -           %  
  None  
Supply  c onnection  –   t ype    ................................ .. :     pluggable equipment  type A  -  
    non - detachable supply cord  
    appliance coupler  
    direct plug - in  
  pluggable equipment  type B  -  
    non - detachable supply cord  
    appliance coupler  
  permanent connection  
  mating connector     other:  PS3,ES1 (EV  battery)  
Considered current rating of protective device
  ................................ ................................ ............   :                 A;           
      Location:     building     equipment  
  N/A  
Equipment mobility   ................................ ..........   :     movable     hand - held     transportable  
  direct plug - in     stationary     for building - in  
  wall /c eiling - mounted        SRME/rack - mounted  
  other:             
Overvoltage  c ategory (OVC)    ...........................   :     OVC I       OVC II     OVC III  
  OVC IV     other:  EV battery  
Class of equipment    ................................ ..........   :     Class I     Class II     Class III  
  Not classif ied                
Special installation location    ...........................   :     N/A       restricted access area  
  outdoor location              
Pollution degree (PD)    ................................ ......   :  
  PD 1       PD 2       PD 3  
Manufacturer’s  specified  T
ma   ...........................   :  
70   °C       Outdoor: minimum               °C  
IP protection class    ................................ ...........   :  
  IPX0       IP___  
Power  s ystems    ................................ .................   :     TN     TT     IT  -               V 
L - L    
  not AC mains  
Altitude during operation (m)    .........................   :  
  2000 m or less     5000   m   
Altitude of test laboratory (m)    ........................   :  
  2000 m or   less                 m  
Mass of equipment (kg)  ................................ ...   :   1. 80   kg   
Page 326 of 406

   
 
Page  15   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  5.2.2 .2   Steady - state voltage and current limits   ....................   :   (See appended table 5.2)   P  
5.2.2.3   Capacitance limits   ................................ .....................   :     N/A  
5.2.2.4   Single pulse limits   ................................ .....................   :   No such single pulse with the  
e quipment   N/A  
5.2.2.5   Limits for repetitive pulses   ................................ ........   :   No such repetitive pulses with 
the   e quipment   N/A  
5.2.2.6   Ringing signals    No Ringing signals   N/A  
5.2.2.7   Audio signals      P  
5.3   Protection against electrical energy sources  
N/A  
5.3.1   General Requirements for accessible parts to 
ordinary, instructed and skilled persons   Only ES1   N/A  
5.3. 1 a)   Accessible ES1/ES2 derived from ES2/ES3 circuits     N/A  
5.3.1 b)   Skilled persons   not unintentional contact ES3 bare 
conductors     N/A  
5.3.2.1   Accessibility to electrical energy sources and 
safeguards      N/A  
  Accessibility to outdoor equipment bare parts     N/A  
5.3.2.2   Contact requirements     N/A  
  Test with test probe from Annex V     -  
5.3.2.2 a)   Air gap  –   electric strength test potential (V)   .............   :     N/A  
5.3.2.2 b)   Air gap  –   distance (mm)    ................................ ...........   :     N/A  
5.3.2.3   Compliance     N/A  
5.3.2.4   Terminals for connecting strippe d wire      N/A  
5.4   Insulation materials and requirements  
N/A  
5.4.1.2   Properties of insulating material      N/A  
5.4.1.3   Material is non - hygroscopic     N/A  
5.4.1.4   Maximum operating temperature for insulating 
materials   ................................ ................................ ....   :     N/A  
5.4.1.5   Pollution degrees   ................................ ......................   :     N/A  
5.4.1.5.2   Test for pollution degree 1 environment and for an 
insulating compound     N/A  
5.4.1.5.3   Thermal cycling test     N/A  
5.4.1.6   Insulation in transformers with varying dimensions     N/A  
5.4.1.7   Insulation in circuits generating starting pulses     N/A  
5. 4.1.8   Determination of working voltage   .............................   :     N/A   
Page 333 of 406

   
 
Page  22   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    Inst ructional Safeguard   ................................ .............   :     N/A  
6.4.8.3.5   Side openings and properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
6.4.8.3.6   Integrity of a fire enclosure, condition met:  a), b) or 
c)   ................................ ................................ ............   :   N ot such fire enclosure   N/A  
6.4.8.4   Separation of a PIS from a fire enclosure and a fire 
barrier distance (mm) or flammability rating   ..........   :   Not such fire enclosure   P  
6.4.9   Flammability of insulating liquid ...............................   :     N/A  
6.5   Internal and external wiring   
P  
6.5.1   Ge neral requirements      P  
6.5.2   Requirements for interconnection to building wiring
  ................................ ................................ ...............   :   No such interconnection to 
building wiring   N/A  
6.5.3   Internal wiring size (mm 2
) for socket - outlets   ..........   :     N/A  
6.6   Safeguards against fire due to the connection to   additional   equipment  
P  
 
7   INJURY CAUSED BY HAZARDOUS SUBSTANCES  
N/A  
7.2   Reduction of exposure to hazardous substances   
N/A  
7.3    Ozone exposure  
N/A  
7.4   Use of personal safeguards   or personal protective equipment   (PPE)  
N/A  
  Personal safeguards and instructions   ...................   :    
  
7.5    Use of instructional safeguards and instructions  
N/A  
  Instructional safeguard (ISO 7010) ........................   :    
  
7.6   Batteries and their protection circuits  
N/A  
 
8   MECHANICALLY - CAUSED INJURY  
P  
8.2   Mechanical energy source classifications  
P  
8.3   Safeguards against   mechanical energy sources  
P  
8.4   Safeguards against parts with sharp edges and corners  
P  
8.4.1   Safeguards   All edges and corners are 
rounded or smoothed   P  
  Instructional Safeguard   ................................ .............   :   MS1   N/A  
8.4.2   Sharp edges or corners      P  
8.5   Safeguards against moving   parts  
N/A   
Page 334 of 406

   
 
Page  23   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  8.5.1   Fingers, jewellery, clothing, hair, etc., contact with 
MS2 or MS3 parts     N/A  
  MS2 or MS3 part required to be accessible for the 
function of the equipment      N/A  
  Moving MS3 parts only accessible to skilled person     N/A  
8.5.2   Instruction al safeguard ................................ ..............   :     N/A  
8.5.4   Special categories of equipment containing moving 
parts     N/A  
8.5.4.1   General     N/A  
8.5.4.2   Equipment containing work cells with MS3 parts     N/A  
8.5.4.2.1   Protection of persons in the work cell     N/A  
8.5.4.2.2   Access protection o verride     N/A  
8.5.4.2.2.1   Override system    
N/A  
8.5.4.2.2.2   Visual indicator    
N/A  
8.5.4.2.3   Emergency stop system    
N/A  
  Maximum stopping distance from the point of 
activation (m)   ................................ .............................   :     N/A  
  Space between end point and nearest fixed 
mechanical part (mm)   ................................ ...............   :     N/A  
8.5.4.2.4   Endurance requirements     N/A  
  Mechanical system subjected to 100 000 cycles of 
operation     N/A  
  -   Mechanical function check and visual inspection      N/A  
  -   Cable assembly   ................................ ......................   :     N/A  
8.5.4.3   Equipment having electromechanical device for 
destruct ion of media      N/A  
8.5.4.3.1   Equipment safeguards     N/A  
8.5.4.3.2   Instructional safeguards against moving parts   ........   :     N/A  
8.5.4.3.3   Disconnection from the supply     N/A  
8.5.4.3.4   Cut type and test force (N)   ................................ ........   :     N/A  
8.5.4.3.5   Compliance     N/A  
8.5.5   High press ure lamps    No High pressure lamps   N/A  
  Explosion test   ................................ ............................   :     N/A  
8.5.5.3   Glass particles dimensions (mm)   .............................   :     N/A  
8.6   Stability of equipment  
N/A   
Page 338 of 406

   
 
Page  27   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    30 s integrated exposure level (MEL30)   ..................   :     N/A  
  Warning fo r MEL ≥ 100 dB(A)   ................................ ..   :     N/A  
10.6.4   Measurement methods     N/A  
10.6.5   Protection of persons     N/A  
  Instructional safeguards   ................................ ........   :     N/A  
10.6.6   Requirements for listening devices (headphones, 
earphones, etc.)     N/A  
10.6.6.1   Corded listening devices with analogue in put     N/A  
  Listening device input voltage (mV) .......................   :     N/A  
10.6.6.2   Corded listening devices with digital input     N/A  
  Max. acoustic output  L
Aeq,T , dB(A)   ............................   :  
  N/A  
10.6.6.3   Cordless listening devices     N/A  
  Max. acoustic output  L
Aeq,T , dB(A)   ............................   :  
  N/A  
 
B   NORMAL OP ERATING CONDITION TESTS, ABNORMAL OPERATING 
CONDITION TESTS AND SINGLE FAULT CONDITION TESTS   P  
B.1   General  
P  
B.1.5   Temperature measurement conditions   (See appended table B.1.5)   P  
B.2   Normal operating conditions  
P  
B.2.1   General requirements   ................................ ............   :   (See Test  Item Particulars and 
appended test tables)   P  
  Audio Amplifiers and equipment with audio 
amplifiers   ................................ ...............................   :   Complied with Annex E   P  
B.2.3   Supply voltage and tolerances   EV battery used   N/A  
B.2.5   Input test   ................................ ................................   :   (See appended table B.2.5)   P  
B.3   Simulated abnormal  operating conditions  
P  
B.3.1   General     P  
B.3.2   Covering of ventilation openings     P  
  Instructional safeguard   ................................ ..........   :   Not used on a soft support   N/A  
B.3.3   DC mains polarity test   The connection is not 
accessible to an ordinary 
person   N/A  
B.3.4   Setting of voltag e selector   No voltage selector   N/A  
B.3.5   Maximum load at output terminals     P  