(2) Temperature control
The blowing air temperature is controlled by the temp actuator and the set temperature can be checked
via the LCD display.
Manual control
The discharge air temperature is controlled by the temperature control dial. The driver can select one
of the 31 levels.
Auto control
When pressing the AUTO switch, "AUTO" is shown on the display and the fan speed and air distribution
mode are adjusted automatically to keep interior temperature to the set temperature. In full AUTO mode,
the FATC receives various signals such as the indoor temperature, ambient temperature, engine coolant
temperature, sunlight, from different sensors to control the A/C compressor, mode actuator, intake
actuator, temp actuator, blower motors, etc. to keep indoor environments fresh.
Max. cooling/heating control (AUTO mode)
If the temperature is set to the lowest level (Lo) or highest level (Hi), the system will go into the maximum
cooling or maximum heating mode regardless of the sensor signals.
Set
temp.A/C
compressorAir outlet
(mode)Air inletBlower
voltageTemp actuator
LO ON Vent Recirculation 10.5 V Max. cooling position
HI OFF Footwell Fresh air 10.5 V Max. heating position
Temperature control dial
LCD display (temperature view)
6810-00
(3) Blower control
In AUTO mode, the blower motor is controlled automatically according to the set temperature and the
blower motor speed can also be controlled manually. The fan speed can be checked via the LCD
display.
Manual control
Auto control
In AUTO mode, the fan speed is automatically controlled depending on the set temperature and
surrounding environment and the blower motor operates steplessly.
Sun load compensation control
The system increases the fan speed by adding up 2.5 V of voltage in direct sunlight.
Blower step Blower motor voltage (V)
1 4.0
25.0
36.0
47.0
5 8.0
6 9.0
7 10.5
8 VIGN
Control for defrosting
When the defrost mode is selected with the blower dial in AUTO position, the blower motor voltage is
increased by 1.5 V compared to the AUTO control voltage for a certain amount of time. Turn the fan speed dial to control the
blower motor manually. The fan speed
increments by 1 level per revolution of the
Fan speed dial
LCD display (fan speed view)
7340-00
2. OPERATING PROCESS
1) Sunroof Switch
This can be closed or open manually to block sunlight when the sunroof function is not in use. The sunroof glass can be open in two steps and can be tilted by the switch operation. The sunroof switches are included in the overhead console switches and consists of the TILT,
CLOSE and OPEN switches.
TILT
CLOSE
OPEN
Sun shade panel Sunroof glass Sunroof switch
Opens only rear section of the sunroof.
Closes the sunroof.
Opens the sunroof.
Sunroof glass
Sun shade panel