SSANGYONG RODIUS 2006 Service Manual
Manufacturer: SSANGYONG, Model Year: 2006, Model line: RODIUS, Model: SSANGYONG RODIUS 2006Pages: 444, PDF Size: 56.32 MB
Page 361 of 444

0-10
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2. AIR CONDITIONER MODULE WIRING AND LAYOUT
1) Front Air Conditioner Module
Wiring layout
Components
Air source selection
door actuatorAir conditioner filterEvaporator
Blower
motor
Blower high
speed relay
Heater core 
Page 362 of 444

0-11
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
2) Rear Air Conditioner Module
Wiring layout
Components
Roof air conditioner duct
Blower motor
EvaporatorAir mixer door actuator
Rear floor heater duct
Mixer door
Heater coreHeater &
air conditioner pipes 
Page 363 of 444

0-12
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
3. AIR CONDITIONER AND HEATER PIPE LAYOUT 
Page 364 of 444

0-13
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
4. SENSORS AND ACTUATORS
1) Sun Sensor
It is installed on the upper left end of instrument panel. It is using characteristics that the 
amount of current changes according to amount of light on the photosensitive surface. Photo 
diode, converts the changes in light intensity into electrical changes, detects the amount of light 
coming through windshield and changes it into current and then sends the signal to FATC 
controller.
(1) Inspection
Remove the sun sensor and measure the current between terminals under sunlight.
Measure the current again under shade. It is in normal conditions if the measured value is 
less than the measured value under sunlight.
Turn the ignition switch to “ON” position.
Measure the voltage to the sun sensor from FATC connector. (approx. 2.5 V under sunlight 
and 4.8 V under shade.)
If the voltage value cannot be measured, check the circuit for open. If the measured value is 
within the specified range, replace the FATC controller. 1.
2.
3.
4.
5. 
Page 365 of 444

0-14
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2) Active Incar/Humidity Sensor (AIH Sensor)
The AIH sensor is installed at the driver side  instrument panel undercover. It is a sensor that  
detects interior temperature and humidity.
(1) Location 
(2) Functions
Interior temperature sensor 
▶ 
This sensor is a negative temperature coefficient (NTC) thermistor and detects the interio
r  
temperature with air coming from senor hole and then sends the voltage value according to the 
changed resistance to FATC controller. 
Humidity sensor 
▶ 
This sensor detects the interior humidity with humidity cell and then sends the voltage value  
according to the changed humidity to FATC controller.
Humidity  
sensor 
Active incar sensor 
(interior temperature
sensor) 
Page 366 of 444

0-15
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
(3) Inspection
If the active incar sensor defect code (DTC 1) and the humidity sensor defect code (DTC 10)  
are set, check as below:
Air conditioner controller 
Air conditioner controller connector  (based on wiring)  AIH sensor (based on sensor) 
Active incar sensor 
▶ 
Remove the integrated AIH sensor and measure the resistance between terminal No. 5 and  
6 on the sensor connector. (standard: approx.   25°C, 2.2 kΩ) 
 If the measured value is out of the specified range, replace the AIH sensor. If the measured 
values are within the specified range, check as below.
Turn the ignition switch to ON position and measure the voltage to active incar sensor from 
the FATC controller connector. (standard: approx. 2 V at   25°C) 
If the voltage value cannot be measured, check the circuit for open. If the measured value is 
within the specified range, replace the FATC controller. 
1. 
2.
3.
4. 
Page 367 of 444

0-16
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
Humidity sensor ▶
Apply 5 V to terminal No. 1 and 3 on the humidity sensor connector.
Connect the positive (+) probe of a tester on No. 2 terminal and the negative (-) probe on 
No. 3 terminal, and measure the output voltage while the voltage is applied.
(output voltage: approx. 0.8 ~ 3.4 V)
Check whether the output voltage is changed when blowing into the inlet of the sensor. I
f 
there is a voltage change, the sensor is in normal condition. However, if the voltage is not 
changed, replace the humidity sensor.
In addition, if the output voltage is extremely high or low even in the specified range, replace 
the humidity sensor. 1.
2.
3.
4. 
Page 368 of 444

0-17
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
5. AIR QUALITY SYSTEM (AQS)
1) Components of AQS
Air Quality System (AQS) changes the air source selection to recirculation mode when polluted  
air is detected through AQS sensor. The air source selection returns back to fresh air intake 
mode after a specified period or the polluted air is disappeared.
AQS sensor and ambient temperature sensor 
AQS sensor 
Ambient  
temperature 
sensor 
Connector
AQS and air source selection switch 
The AQS switch is integrated with the air source selection switch. 
AUTO Mode 
The air source is not changed when pressing the AQS and air 
source selection switch in “AUTO” mode. However, the 
indicator on the switch turned ON/OFF. In other words, the air 
source cannot be changed to recirculation mode in AUTO mode 
by just pressing the switch. To change the air source to 
recirculation mode in AUTO mode, get into Manual mode first, 
then press the air source selection switch. 
Manual Mode 
To change the AQS mode to Manual mode from AUTO mode, 
use the MODE switch or the fan speed control dial. In Manual 
mode, the “AUTO” symbol on the display is disappeared. 
When pressing the AQS and air source selection switch, the 
mode is changed in order of AQS LED ON, AQS LED OFF 
(fresh air), and air source LED ON (recirculation).
The figure shows that the mode has been changed to the 
recirculation mode from fresh air mode under AQS mode (AQS 
LED ON) after detecting the polluted outside air. 
Page 369 of 444

0-18
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2) AQS Operation
The AQS operates under air conditioner AUTO mode or when the AQS switch is pressed under  
manual mode. It requires preheating time (for seconds) for operation and the module and 
sensor are integrated. (However, it operates only when the DEF (defroster) switch on the ai
r 
conditioner switch panel is not pressed in.) 
Self diagnosis and preheating process during initial operation of A/C controller  
(AUTO mode) 
1. 
AQS operation (AQS switch is pressed in): detecting the polluted outside air 
2.
When the air conditioner controller is operated  
in AUTO mode during its initial operation, the 
air source is changed to the recirculation 
mode and AQS LED comes on.
(This is the self diagnosis and preheating 
process for AQS.) 
1. 
After completing the above process, the 
AQS 
LED is turned off and the air source is 
automatically changed to the fresh air mode. 
2.
If the AQS switch is pressed in, the AQS 
function works regardless of air conditioner 
controller operation. 
When pressing the AQS switch, the LED on  
the AQS switch is turned on and the 
AQS
function is activated.
When the polluted outside air is detected, the 
AQS operates and converts the air source to 
recirculation mode automatically. At this 
moment, the recirculation mode indicato
r 
comes on in the display. 
1. 
2. 
Page 370 of 444

0-19
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
When driving out of polluted area 3.
If the polluted air is disappeared, the air 
source is automatically changed to the fresh 
air mode and AQS LED stays on.
The air source is not changed when pressing 
the AQS and air source selection switch in 
“AUTO” mode. To change the air source to 
recirculation mode in AUTO mode, get into 
Manual mode first, then press the air source 
selection switch. 1.
2.