Power switch SUZUKI GRAND VITARA 2002 2.G Service Repair Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2002, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 2002 2.GPages: 801, PDF Size: 12.15 MB
Page 579 of 801

YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
Page 580 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-25
POWER DOOR LOCK ACTUATOR CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is satisfactory, this circuit is OK.
POWER SUPPLY AND GROUNDING CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimeContinuity
If check result is satisfactory, this circuit is OK.
DOOR LOCK KEY AND POWER DOOR LOCK SWITCH
CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Check for continuity between following terminals at each condi-
tion.
Terminals
ConditionSpecification
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is satisfactory, this circuit is OK.
Page 581 of 801

YH4
GRAND
VITARA
8D-26 WINDOWS, MIRRORS, SECURITY AND LOCKS
IGNITION SWITCH AND DOOR SWITCH CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-4 and
When ignition switch is OFF
position0 V
groundWhen ignition switch is ON
position10 ± 14 V
E02 10 andWhen all doors are closedNo continuityE02-10 and
groundWhen any one door is
openedContinuity
If check result is satisfactory, this circuit is OK.
DOOR KNOB SWITCH AND TURN SIGNAL RELAY CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-6 and
groundAnytime10 ± 14 V
E02-11 and
When driver side door lock
knob is pulled upContinuity
groundWhen driver side door lock
knob is pushed downNo continuity
If check result is satisfactory, this circuit is OK.
Page 582 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-27
POWER DOOR LOCK SWITCH
INSPECTION
Refer to POWER DOOR LOCK SWITCH INSPECTION of POWER
DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT EQUIPPED)
in this section.
KEY CYLINDER SWITCH (DRIVER SIDE)
INSPECTION
Refer to KEY CYLINDER SWITCH (DRIVER SIDE) INSPECTION
of POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
POWER DOOR LOCK ACTUATOR
INSPECTION
Refer to POWER DOOR LOCK ACTUATOR INSPECTION of
POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
Page 585 of 801

YH4
GRAND
VITARA
Terminal
Operation
If mirror heater is not equipped
If mirror heater is equipped
8D-30 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR MIRROR CONTROL SYSTEM
INSPECTION
MIRROR SWITCH
1) Remove mirror switch from instrument panel.
2) Check for continuity between terminals at each switch position
as shown below.
If check result is not as specified, replace mirror switch.
DOOR MIRROR ACTUATOR
1) Remove garnish from door.
2) Disconnect door mirror coupler.
3) Check that door mirror operates properly when battery voltage
is applied to connector terminals.
Connect battery positive and negative terminal to the door mirror
terminal shown below and check operation.
If it does not operate as specified in table below, replace door
mirror assembly.
VBlYVBlY
Up
Down
Left
Right
NOTE:
When installing door mirror to door, be careful not to pinch
harness between door and door mirror.
Page 587 of 801

YH4
GRAND
VITARA
8D-32 WINDOWS, MIRRORS, SECURITY AND LOCKS
3. To open
4. To close
3. Left turn
4. Right turn
Terminal
Switch
Terminal
Switch
POWER SLIDING ROOF (IF EQUIPPED)
INSPECTION
SLIDING ROOF SWITCH
Check switch for continuity between terminals as shown below.
Slide Switch (1)
CDFCDF
OPEN
OFF
CLOSE
Tilt Switch (2)
EDBEDB
UP
OFF
DOWN
SLIDING ROOF MOTOR ASSEMBLY
1) Remove head lining. Refer to Section 9 for detail.
2) Remove sliding roof motor assembly (1).
3) Connect known-good sliding roof switch (2) to sliding roof motor
assembly.
4) Connect 12 V battery positive terminal to terminal ªAº of motor
assembly (1) and battery negative terminal to terminal ªBº of mo-
tor assembly (1).
5) Check that the sliding roof motor (1) runs according to the move-
ment of the sliding roof switch (2).
Sliding Roof Switch
Motor
Tilt upturns left
Tilt downturns right
Slide openturns right
Slide closeturns left
If motor does not operate as above, replace sliding roof motor
assembly (1).
Page 590 of 801

YH4
GRAND
VITARA
1. Coil antenna
2. Ignition key
3. Immobilizer control module
4. Data link connector (DLC)
5. Immobilizer diagnostic coupler Ignition key
Transponder
code
Immobilizer
Control
ModuleECM/
PCM
8G-2 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
GENERAL DESCRIPTION
The immobilizer control system designed to prevent vehicle burglar consists of following components.
Engine control module (ECM) / Powertrain control module (PCM)
Immobilizer control module
Ignition key (with built-in transponder)
Coil antenna
Operation of this system is as follows.
(1) Each ignition key has its own code (Transponder code) stored in memory. When the ignition switch is turned
ON, Immobilizer Control Module tries to read the Transponder code through the coil antenna installed to the
steering lock assembly.
(2) Immobilizer Control Module compares the Transponder code read in (1) and that registered in Immobilizer Con-
trol Module and checks if they match.
(3) When it is confirmed that two Transponder codes match each other as described above, Immobilizer Control
Module and ECM / PCM check if ECM/Immobilizer Control Module codes registered in them respectively match.
(4) Only when it is confirmed that ECM/Immobilizer Control Module codes match, the engine starts running. If
Transponder codes in Step (2) or ECM/Immobilizer Control Module codes in Step (3) do not match, ECM / PCM
will stop operation of the injector and ignition of spark plug.
Page 612 of 801

YH4
GRAND
VITARA
8G-24 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
1
2
3
1
2
1. Immobilizer Control Module
2. Immobilizer Control Module Coupler
3. Body ground
INSPECTION OF ECM / PCM, IMMOBILIZER
CONTROL MODULE AND ITS CIRCUIT
ECM / PCM, Immobilizer Control Module and its circuit can be
checked at ECM / PCM wiring couplers and Immobilizer Control
Module wiring coupler by measuring voltage and resistance. De-
scribed here is only inspection of Immobilizer Control Module. For
inspection of ECM / PCM, refer to ªSECTION 6E1 or 6E2º.
CAUTION:
Immobilizer Control Module cannot be checked by itself. It
is strictly prohibited to connect voltmeter or ohmmeter to
Immobilizer Control Module with coupler disconnected
from it.
Voltage Check
1) Remove Immobilizer Control Module from body with ignition
switch OFF, referring to p. 8G-24.
2) Connect Immobilizer Control Module coupler to Immobilizer
Control Module.
3) Check voltage at each terminal of coupler connected.
NOTE:
As each terminal voltage is affected by the battery voltage,
confirm that it is 11 V or more when ignition switch is ON.
TERMINALCIRCUITNORMAL
VOLTAGECONDITION
A1Coil antenna 10 V
A2Coil antenna 20 VIgnition switch ON
A3Power source10 ± 14 V
A4Ignition signal10 ± 14 VIgnition switch ONA4Ignition signal0 ± 0.8 VIgnition switch OFF
A5Diagnosis output0 ± 14 VIgnition switch ONA5Diagnosis output0 VIgnition switch OFF
A6Blank±±
A7Ground±±
A8Data link connector
(Serial data terminal)4 ± 5 VIgnition switch ON
A9
A10Blank±±
NOTE:
When measuring voltage at A1 and A2 terminals with ignition switch turned ON, be sure to turn ignition
switch ON before connecting positive probe of voltmeter to A1 or A2 terminal. If it is not turned ON first,
DTC13 (Diagnostic Trouble Code 13) may be indicated.
Page 618 of 801

YH4
GRAND
VITARA
8G-30 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead/probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version1.5 or more
PROCEDURE AFTER ECM / PCM
REPLACEMENT
When ECM / PCM was replaced, including when replaced because
rechecking by using a known-good ECM / PCM was necessary dur-
ing trouble diagnosis, register ECM/Immobilizer Control Module
code in ECM / PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section. And then turn ignition switch ON.
2) Using TECH1, register ECM/Immobilizer Control Module code in
ECM / PCM by executing ªRECORD ECU (RECORD ECM / PCM/
ICM)º command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to TECH1
operator's manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS
Page 621 of 801

YH4
GRAND
VITARA
1. Screws 1. Door outside weatherstrip
2. Screw1. Door inside pull handle bracket
BODY SERVICE 9-3
REMOVAL
1) Remove inside handle bezel.
2) Remove door mirror bezel (if equipped).
3) Remove inside lock knob and door inside pull handle case fitting
screw.
3-1) Remove window regulator handle (if equipped).
To remove regulator handle, pull off snap ring by using a cloth
as shown below.
4) Remove door trim.
With inside handle bezel tilted as shown in figure, turn door trim
90 counterclockwise to remove it.
And disconnect power window switch lead wire at coupler (if
equipped).
5) Remove door inside pull handle bracket.
6) Remove door sealing cover.
7) Remove door outside weatherstrip.
Lower window all the way down. Then, use a tape-wrapped putty
knife (or screwdriver) to pry off weatherstrip.
CAUTION:
Use a tape-wrapped putty knife (or screwdriver) to pry off
weatherstrip. Use of an unwrapped tool will cause dam-
age to painting.
8) Remove glass attaching screws.
9) Take out door glass.